Skip to main content

2020 | OriginalPaper | Buchkapitel

Pre-clinical Analysis of Implanted Ankle Joint Using Finite Element Method

verfasst von : Subrata Mondal, Rajesh Ghosh

Erschienen in: Advances in Fluid Mechanics and Solid Mechanics

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Slacken off of the implant component, dislocation, misalignment, fracture, wear in meniscal bearing, etc. are the most important reasons behind the failure of ankle arthroplasty. The study on the effects of implant material on tibia bone stress due to total ankle replacement (TAR) is the prime goal of this paper. Computed tomography (CT) scan data was used to develop the bones, and other soft tissues for the intact and implanted ankle joint. Three implanted FE models were generated having a different combination of implant material. The implanted FE model 1 is having the implant material combination of metal and ultra-high molecular weight polyethylene (UHMWPE). The combination of implant material in FE model 2 was ceramic and UHMWPE, whereas FE model 3 consists of the implant material combination of ceramic and carbon-fiber-reinforced polyetheretherketone (CFR-PEEK), respectively. Three positions during gait such as dorsiflexion, neutral, and plantar flexion positions were considered as applied loading condition, along with muscle force and ligaments. Stress shielding was found in the proximal region of the tibia (i.e., away from the implant neighborhood) due to implantation. Implant material combinations have less impact on tibia bone stress. The present outcome recommended that ceramic can be used as a substitute for metal and CFR-PEEK as an alternate to UHMWPE owing to the high metal release of metal and UHMWPE for long-standing attainment of the prosthetic components.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Ghosh R, Mukharjee K, Gupta S (2013) Bone remodelling around uncemented metallic and ceramic acetabular components. Proc Inst Mech Eng Part H: J Eng Med 227(5):490–502CrossRef Ghosh R, Mukharjee K, Gupta S (2013) Bone remodelling around uncemented metallic and ceramic acetabular components. Proc Inst Mech Eng Part H: J Eng Med 227(5):490–502CrossRef
3.
Zurück zum Zitat Ghosh R, Gupta S (2014) Bone remodelling around cementless composite acetabular components: the effects of implant geometry and implant-bone interfacial conditions. J Mech Behav Biomed Mater 32:257–269CrossRef Ghosh R, Gupta S (2014) Bone remodelling around cementless composite acetabular components: the effects of implant geometry and implant-bone interfacial conditions. J Mech Behav Biomed Mater 32:257–269CrossRef
4.
Zurück zum Zitat Manley MT, Ong KL, Kurtz SM (2006) The potential for bone loss in acetabular structures following THA. Clin Orthop Relat Res 453:246–253CrossRef Manley MT, Ong KL, Kurtz SM (2006) The potential for bone loss in acetabular structures following THA. Clin Orthop Relat Res 453:246–253CrossRef
5.
Zurück zum Zitat Reggiani B, Leardini A, Corazza F (2006) Finite element analysis of total ankle replacement during the stance phase of gait. J Biomech 39:1435–1443CrossRef Reggiani B, Leardini A, Corazza F (2006) Finite element analysis of total ankle replacement during the stance phase of gait. J Biomech 39:1435–1443CrossRef
6.
Zurück zum Zitat Espinosa N, Walti M, Favre P (2010) Misalignment of total ankle components can induce high joint contact pressures. J Bone Jt Surg 92:1179–1187CrossRef Espinosa N, Walti M, Favre P (2010) Misalignment of total ankle components can induce high joint contact pressures. J Bone Jt Surg 92:1179–1187CrossRef
7.
Zurück zum Zitat Sopher SR, Andrew AA, James DC (2017) Total ankle replacement design and positioning affect implant-bone micromotion and bone strains. Med Eng Phys 42:80–90CrossRef Sopher SR, Andrew AA, James DC (2017) Total ankle replacement design and positioning affect implant-bone micromotion and bone strains. Med Eng Phys 42:80–90CrossRef
9.
Zurück zum Zitat Putra AMS, Harun MN, Ardiyansyah S (2014) Study of wear prediction on total ankle replacement. Adv Mater Res 845:311–315CrossRef Putra AMS, Harun MN, Ardiyansyah S (2014) Study of wear prediction on total ankle replacement. Adv Mater Res 845:311–315CrossRef
10.
Zurück zum Zitat Smyth A, Fisher J, Suner S (2017) Influence of kinematics on the wear of a total ankle replacement. J Biomech 53:105–110CrossRef Smyth A, Fisher J, Suner S (2017) Influence of kinematics on the wear of a total ankle replacement. J Biomech 53:105–110CrossRef
12.
Zurück zum Zitat Mondal S, Ghosh R (2017) A numerical study on stress distribution across the ankle joint: Effects of material distribution of bone, muscle force and ligaments. J Orthop 14:329–335CrossRef Mondal S, Ghosh R (2017) A numerical study on stress distribution across the ankle joint: Effects of material distribution of bone, muscle force and ligaments. J Orthop 14:329–335CrossRef
13.
Zurück zum Zitat Linde F, Hvid I, Madsen F (1992) The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens. J Biomech 25:359–368CrossRef Linde F, Hvid I, Madsen F (1992) The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens. J Biomech 25:359–368CrossRef
14.
Zurück zum Zitat STAR Surgical Technique—Small Bone Innovations, Inc. Cited 4 Mar 2013 STAR Surgical Technique—Small Bone Innovations, Inc. Cited 4 Mar 2013
15.
Zurück zum Zitat Beumar A, Hemert WLV, Swierstra BA (2003) A biomechanical evaluation of the tibiofibular and tibiotalar ligaments of the ankle. Foot Ankle Int 24:426–429CrossRef Beumar A, Hemert WLV, Swierstra BA (2003) A biomechanical evaluation of the tibiofibular and tibiotalar ligaments of the ankle. Foot Ankle Int 24:426–429CrossRef
16.
Zurück zum Zitat Liacouras PC, Wayne JS (2007) Computational modelling to predict mechanical function of joints: application to the lower leg simulation of two cadaver studies. J Biomech Eng 129:811–817CrossRef Liacouras PC, Wayne JS (2007) Computational modelling to predict mechanical function of joints: application to the lower leg simulation of two cadaver studies. J Biomech Eng 129:811–817CrossRef
17.
Zurück zum Zitat Corazza F, O’Connor JJ, Leardini A (2003) Ligament fibre recruitment and forces for the anterior drawer test at the human ankle joint. J Biomech 36(3):363–372CrossRef Corazza F, O’Connor JJ, Leardini A (2003) Ligament fibre recruitment and forces for the anterior drawer test at the human ankle joint. J Biomech 36(3):363–372CrossRef
18.
Zurück zum Zitat Bekerom VDMP, Raven EE (2007) The distal fascicle of the anterior inferior tibiofibular ligament as a cause of tibiotalar impingement syndrome: a current concepts review. Knee Surg Sports Traumatol Arthrosc 15(4):465–471CrossRef Bekerom VDMP, Raven EE (2007) The distal fascicle of the anterior inferior tibiofibular ligament as a cause of tibiotalar impingement syndrome: a current concepts review. Knee Surg Sports Traumatol Arthrosc 15(4):465–471CrossRef
20.
Zurück zum Zitat Seireg A, Arvikar RJ (1975) The prediction of muscular load shearing and joint forces in the lower extremities during walking. J Biomech 8:89–102CrossRef Seireg A, Arvikar RJ (1975) The prediction of muscular load shearing and joint forces in the lower extremities during walking. J Biomech 8:89–102CrossRef
21.
Zurück zum Zitat Ozen M, Sayman O, Havitcioglu H (2013) Modelling and stress analyses of a normal foot-ankle and a prosthetic foot-ankle complex. Acta Bioeng Biomech 15(3):19–27 Ozen M, Sayman O, Havitcioglu H (2013) Modelling and stress analyses of a normal foot-ankle and a prosthetic foot-ankle complex. Acta Bioeng Biomech 15(3):19–27
Metadaten
Titel
Pre-clinical Analysis of Implanted Ankle Joint Using Finite Element Method
verfasst von
Subrata Mondal
Rajesh Ghosh
Copyright-Jahr
2020
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-15-0772-4_12

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.