Preprocessing of the BSPM Signals with Untraditionally Strong Baseline Wandering

verfasst von : Michal Huptych, Matěj Hrachovina, Lenka Lhotská

Erschienen in: World Congress on Medical Physics and Biomedical Engineering 2018

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The BSPM is a special setup of the ECG measurement with many of electrodes (20–256) on the body surface. Results of the measurement are strongly dependent on many conditions like body shape, contact of electrodes and skin, patient position and movements. Of course, these conditions are crucial also for standard ECG measurement, but obviously, problems with the conditions are more probable during the BSPM signals acquisition. In this paper, we would like to present a problem with the Body Surface Potential Mapping (BSPM) ECG preprocessing caused by unexpected signal interruption due to the significant baseline wandering and derivate problems which are generated by solving of this baseline wandering filtration. This problem is major for next signal processing (mainly ECG delineation) because the baseline wandering problem is closely connected with the determination of ECG signals’ isoline. We use a system of 120 electrodes on body front and back. The experimental measurements are arranged in the clinical environment with maximal treatment to electrodes position and contact of electrodes and skin at the beginning of the measurement. Unfortunately, obtained signals contain often extreme baseline wandering bedsides of standard artefacts. This baseline wandering seems to be created most likely by patient movements and a change of the electrodes contact. Moreover, we have observed that the standard artefact filtration and the extreme baseline wandering filtration are against each other.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Abraham WT, Fisher WG, Smith Al, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med 2002; 346(24):1845–53. Abraham WT, Fisher WG, Smith Al, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med 2002; 346(24):1845–53.
2.
Zurück zum Zitat Cleland JG, Daubert JC, Erdmann E, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 2005;352(15):1539–49. Cleland JG, Daubert JC, Erdmann E, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 2005;352(15):1539–49.
3.
Zurück zum Zitat Bristow MR, Saxon LA, Boehmer J, et al. and the Comparison of Medical Therapy, Pacing And Defibrillation in Heart Failure Investigators. Cardiac resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004; 350:2140–2150. Bristow MR, Saxon LA, Boehmer J, et al. and the Comparison of Medical Therapy, Pacing And Defibrillation in Heart Failure Investigators. Cardiac resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004; 350:2140–2150.
4.
Zurück zum Zitat Brignole M, Auricchio A, Baron-Esquivias G, et al. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J 2013; 34:2281–2329. Brignole M, Auricchio A, Baron-Esquivias G, et al. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J 2013; 34:2281–2329.
6.
Zurück zum Zitat Giffard-Roisin, S., T. Jackson, L. Fovargue, et al. ‘Noninvasive Personalization of a Cardiac Electrophysiology Model from Body Surface Potential Mapping’, IEEE Transactions on Biomedical Engineering, vol. 64/no. 9, (2017), pp. 2206–2218. Giffard-Roisin, S., T. Jackson, L. Fovargue, et al. ‘Noninvasive Personalization of a Cardiac Electrophysiology Model from Body Surface Potential Mapping’, IEEE Transactions on Biomedical Engineering, vol. 64/no. 9, (2017), pp. 2206–2218.
7.
Zurück zum Zitat Wang, Yong, and Yoram Rudy. ‘Application of the Method of Fundamental Solutions to Potential-Based Inverse Electrocardiography’, Annals of Biomedical Engineering, vol. 34/no. 8, (2006), pp. 1272–1288. Wang, Yong, and Yoram Rudy. ‘Application of the Method of Fundamental Solutions to Potential-Based Inverse Electrocardiography’, Annals of Biomedical Engineering, vol. 34/no. 8, (2006), pp. 1272–1288.
8.
Zurück zum Zitat Taji, Bahareh, Shervin Shirmohammadi, Voicu Groza, and Izmail Batkin. 2014. Impact of skin-electrode interface on electrocardiogram measurements using conductive textile electrodes. IEEE Transactions on Instrumentation and Measurement 63 (6): 1412–22. Taji, Bahareh, Shervin Shirmohammadi, Voicu Groza, and Izmail Batkin. 2014. Impact of skin-electrode interface on electrocardiogram measurements using conductive textile electrodes. IEEE Transactions on Instrumentation and Measurement 63 (6): 1412–22.
9.
Zurück zum Zitat Buendía-Fuentes, F., M. A. Arnau-Vives, A. Arnau-Vives, et al. ‘High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment’, ISRN Cardiology, vol. 2012 (2012), 10 pages. Buendía-Fuentes, F., M. A. Arnau-Vives, A. Arnau-Vives, et al. ‘High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment’, ISRN Cardiology, vol. 2012 (2012), 10 pages.
Metadaten
Titel
Preprocessing of the BSPM Signals with Untraditionally Strong Baseline Wandering
verfasst von
Michal Huptych
Matěj Hrachovina
Lenka Lhotská
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-9038-7_86

Neuer Inhalt