1. Introduction
2. Environment, Measurement Equipment, and Methodology
2.1. Description of the Environment
2.2. Measurement Equipment
2.3. Methodology
Frequency band | 2.8–5 GHz |
---|---|
Number of frequency points | 1601 |
Antenna | Biconical antenna (Electrometrics EM-6116) |
Transmitter power | 20 dBm |
Dynamic range | >100 dB |
Position in the transverse plane | 12 positions every 3 cm (λ/2 at 5 GHz) |
Positions along the longitudinal axis | From 50 m to 202 m every 4 m |
From 202 m to 500 m every 6 m | |
Number of acquisitions at each position | 5 |
3. Path Loss and Correlation Along the Longitudinal Axis
3.1. Path Loss
3.2. Axial Correlation
4. Field Distribution in the Transverse Plane
4.1. Field Distribution Function
4.2. Ricean Factor
Values | −79 | 6.73 | 3.6 | −0.37 | 4.9 |