Skip to main content

2019 | OriginalPaper | Buchkapitel

Proposal of Electrode for Measuring Glucose Concentration in Blood

verfasst von : Klara Fiedorova, Martin Augustynek, Tomas Klinkovsky

Erschienen in: World Congress on Medical Physics and Biomedical Engineering 2018

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The article deals with the design of the electrode system and the appropriate measuring circuit for the measurement of blood glucose concentration, since the determination of the level of blood glucose is an integral part of many medical procedures for determining the state of the human organism. The aim of the concept is to create two functional devices with different design of the electrode system and to perform a series of measurements to verify the functionality and the data statistically process. There was used the principle of resistive sensing of non-electric quantities, so the designed systems using gold electrodes working as electrolytic sensors. The problem relating to the measuring circuit, which is the same for both electrode systems, has been solved by a microampere meter which can convert the generated signal to a suitable measured electrical signal. The signal is formed by the reaction of glucose and enzyme, the resulting value being directly proportional to the glucose concentration. At this work, created systems fully meet specified conditions and requirements. The research confirmed the functionality of the designed units. On the basis of obtained data is possible to compare and evaluate the constructed electrode systems and to make the basis for further development in the subject matter.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Baumstark, A., et al.: Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose. ISO 15197. Journal of diabetes science and technology 6.5 (2012): 1076–1086. Baumstark, A., et al.: Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose. ISO 15197. Journal of diabetes science and technology 6.5 (2012): 1076–1086.
2.
Zurück zum Zitat Scheller, F., Schubert, F.: Biosensors. New York: Elsevier, 1992. ISBN 0-444-98783-5. Scheller, F., Schubert, F.: Biosensors. New York: Elsevier, 1992. ISBN 0-444-98783-5.
3.
Zurück zum Zitat Clarke, S. F., Foster J. R.: A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. British journal of biomedical science 69.2 (2012): 83. Clarke, S. F., Foster J. R.: A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. British journal of biomedical science 69.2 (2012): 83.
4.
Zurück zum Zitat Chang, T., Ming, S.: Biomedical applications of immobilized enzymes and proteins. Vol. 1. Springer Science & Business Media, 2013. Chang, T., Ming, S.: Biomedical applications of immobilized enzymes and proteins. Vol. 1. Springer Science & Business Media, 2013.
5.
Zurück zum Zitat Holzinger, U., et al.: Real-time continuous glucose monitoring in critically ill patients. Diabetes care 33.3 (2010): 467–472. Holzinger, U., et al.: Real-time continuous glucose monitoring in critically ill patients. Diabetes care 33.3 (2010): 467–472.
6.
Zurück zum Zitat Hruška, F.: Senzory: fyzikální principy, úpravy signálů, praktické použití. (2011). Hruška, F.: Senzory: fyzikální principy, úpravy signálů, praktické použití. (2011).
Metadaten
Titel
Proposal of Electrode for Measuring Glucose Concentration in Blood
verfasst von
Klara Fiedorova
Martin Augustynek
Tomas Klinkovsky
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-9023-3_145

Neuer Inhalt