Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 6/2016

01.06.2016 | Original Article

Registration of a statistical model to intraoperative ultrasound for scaphoid screw fixation

verfasst von: Emran Mohammad Abu Anas, Alexander Seitel, Abtin Rasoulian, Paul St. John, Tamas Ungi, Andras Lasso, Kathryn Darras, David Wilson, Victoria A. Lessoway, Gabor Fichtinger, Michelle Zec, David Pichora, Parvin Mousavi, Robert Rohling, Purang Abolmaesumi

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 6/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose

Volar percutaneous scaphoid fracture fixation is conventionally performed under fluoroscopy-based guidance, where surgeons need to mentally determine a trajectory for the insertion of the screw and its depth based on a series of 2D projection images. In addition to challenges associated with mapping 2D information to a 3D space, the process involves exposure to ionizing radiation. Three-dimensional ultrasound has been suggested as an alternative imaging tool for this procedure; however, it has not yet been integrated into clinical routine since ultrasound only provides a limited view of the scaphoid and its surrounding anatomy.

Methods

We propose a registration of a statistical wrist shape + scale + pose model to a preoperative CT and intraoperative ultrasound to derive a patient-specific 3D model for guiding scaphoid fracture fixation. The registered model is then used to determine clinically important intervention parameters, including the screw length and the trajectory of screw insertion in the scaphoid bone.

Results

Feasibility experiments are performed using 13 cadaver wrists. In 10 out of 13 cases, the trajectory of screw suggested by the registered model meets all clinically important intervention parameters. Overall, an average 94 % of maximum allowable screw length is obtained based on the measurements from gold standard CT. Also, we obtained an average 92 % successful volar accessibility, which indicates that the trajectory is not obstructed by the surrounding trapezium bone.

Conclusions

These promising results indicate that determining clinically important screw insertion parameters for scaphoid fracture fixation is feasible using 3D ultrasound imaging. This suggests the potential of this technology in replacing fluoroscopic guidance for this procedure in future applications.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Anas EMA, Rasoulian A, John PS, Pichora DR, Rohling R, Abolmaesumi P (2014) A statistical shape+ pose model for segmentation of wrist CT images. SPIE Med Imaging 9034:T1–8 Anas EMA, Rasoulian A, John PS, Pichora DR, Rohling R, Abolmaesumi P (2014) A statistical shape+ pose model for segmentation of wrist CT images. SPIE Med Imaging 9034:T1–8
2.
Zurück zum Zitat Anas EMA, Seitel A, Rasoulian A, John PS, Pichora D, Darras K, Wilson D, Lessoway VA, Hacihaliloglu I, Mousavi P, Rohling R, Abolmaesumi P (2015) Bone enhancement in ultrasound using local spectrum variations for guiding percutaneous scaphoid fracture fixation procedures. Int J Comput Assist Radiol Surg 10(6):1–11CrossRef Anas EMA, Seitel A, Rasoulian A, John PS, Pichora D, Darras K, Wilson D, Lessoway VA, Hacihaliloglu I, Mousavi P, Rohling R, Abolmaesumi P (2015) Bone enhancement in ultrasound using local spectrum variations for guiding percutaneous scaphoid fracture fixation procedures. Int J Comput Assist Radiol Surg 10(6):1–11CrossRef
3.
Zurück zum Zitat Arora R, Gschwentner M, Krappinger D, Lutz M, Blauth M, Gabl M (2007) Fixation of nondisplaced scaphoid fractures: making treatment cost effective. Arch Orthop Trauma Surg 127(1):39–46 Arora R, Gschwentner M, Krappinger D, Lutz M, Blauth M, Gabl M (2007) Fixation of nondisplaced scaphoid fractures: making treatment cost effective. Arch Orthop Trauma Surg 127(1):39–46
4.
Zurück zum Zitat Beek M, Abolmaesumi P, Luenam S, Ellis RE, Sellens RW, Pichora DR (2008) Validation of a new surgical procedure for percutaneous scaphoid fixation using intra-operative ultrasound. Med Image Anal 12(2):152–162CrossRefPubMed Beek M, Abolmaesumi P, Luenam S, Ellis RE, Sellens RW, Pichora DR (2008) Validation of a new surgical procedure for percutaneous scaphoid fixation using intra-operative ultrasound. Med Image Anal 12(2):152–162CrossRefPubMed
5.
Zurück zum Zitat Bossa M, Olmos S (2007) Multi-object statistical pose+ shape models. In: 4th IEEE international symposium on biomedical imaging: from nano to macro. IEEE, pp 1204–1207 Bossa M, Olmos S (2007) Multi-object statistical pose+ shape models. In: 4th IEEE international symposium on biomedical imaging: from nano to macro. IEEE, pp 1204–1207
6.
Zurück zum Zitat Brudfors M, Seitel A, Rasoulian A, Lasso A, Lessoway VA, Osborn J, Maki A, Rohling RN, Abolmaesumi P (2015) Towards real-time, tracker-less 3D ultrasound guidance for spine anaesthesia. Int J Comput Assist Radiol Surg 10(6):1–11CrossRef Brudfors M, Seitel A, Rasoulian A, Lasso A, Lessoway VA, Osborn J, Maki A, Rohling RN, Abolmaesumi P (2015) Towards real-time, tracker-less 3D ultrasound guidance for spine anaesthesia. Int J Comput Assist Radiol Surg 10(6):1–11CrossRef
7.
Zurück zum Zitat Dodds SD, Panjabi MM, Slade JF (2006) Screw fixation of scaphoid fractures: a biomechanical assessment of screw length and screw augmentation. J Hand Surg 31(3):405–413CrossRef Dodds SD, Panjabi MM, Slade JF (2006) Screw fixation of scaphoid fractures: a biomechanical assessment of screw length and screw augmentation. J Hand Surg 31(3):405–413CrossRef
8.
Zurück zum Zitat Duckworth AD, Jenkins PJ, Aitken SA, Clement ND, McQueen MM (2012) Scaphoid fracture epidemiology. J Trauma Acute Care Surg 72(2):E41–E45 Duckworth AD, Jenkins PJ, Aitken SA, Clement ND, McQueen MM (2012) Scaphoid fracture epidemiology. J Trauma Acute Care Surg 72(2):E41–E45
9.
Zurück zum Zitat Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, Buatti J, Aylward S, Miller JV, Pieper S, Kikinis R (2012) 3D slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30(9):1323–1341 Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, Buatti J, Aylward S, Miller JV, Pieper S, Kikinis R (2012) 3D slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30(9):1323–1341
10.
Zurück zum Zitat Garcia RM, Ruch DS (2014) Management of scaphoid fractures in the athlete: open and percutaneous fixation. Sports Med Arthrosc Rev 22(1):22–28CrossRef Garcia RM, Ruch DS (2014) Management of scaphoid fractures in the athlete: open and percutaneous fixation. Sports Med Arthrosc Rev 22(1):22–28CrossRef
11.
Zurück zum Zitat Lasso A, Heffter T, Rankin A, Pinter C, Ungi T, Fichtinger G (2014) Plus: open-source toolkit for ultrasound-guided intervention systems. IEEE Trans Biomed Eng 61(10):2527–2537CrossRefPubMedPubMedCentral Lasso A, Heffter T, Rankin A, Pinter C, Ungi T, Fichtinger G (2014) Plus: open-source toolkit for ultrasound-guided intervention systems. IEEE Trans Biomed Eng 61(10):2527–2537CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Leventhal EL, Wolfe SW, Walsh EF, Crisco JJ (2009) A computational approach to the “optimal” screw axis location and orientation in the scaphoid bone. J Hand Surg 34(4):677–684CrossRef Leventhal EL, Wolfe SW, Walsh EF, Crisco JJ (2009) A computational approach to the “optimal” screw axis location and orientation in the scaphoid bone. J Hand Surg 34(4):677–684CrossRef
13.
Zurück zum Zitat Liverneaux PA, Gherissi A, Stefanelli MB (2008) Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation. Int J Med Robot Comput Assist Surg 4(2):165–173CrossRef Liverneaux PA, Gherissi A, Stefanelli MB (2008) Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation. Int J Med Robot Comput Assist Surg 4(2):165–173CrossRef
14.
Zurück zum Zitat Maleike D, Nolden M, Meinzer HP, Wolf I (2009) Interactive segmentation framework of the medical imaging interaction toolkit. Comput Methods Programs Biomed 96(1):72–83CrossRefPubMed Maleike D, Nolden M, Meinzer HP, Wolf I (2009) Interactive segmentation framework of the medical imaging interaction toolkit. Comput Methods Programs Biomed 96(1):72–83CrossRefPubMed
15.
Zurück zum Zitat Meermans G, Verstreken F (2008) Percutaneous transtrapezial fixation of acute scaphoid fractures. J Hand Surg (European Volume) 33(6):791–796CrossRef Meermans G, Verstreken F (2008) Percutaneous transtrapezial fixation of acute scaphoid fractures. J Hand Surg (European Volume) 33(6):791–796CrossRef
16.
Zurück zum Zitat Moore DC, Crisco JJ, Trafton TG, Leventhal EL (2007) A digital database of wrist bone anatomy and carpal kinematics. J Biomech 40(11):2537–2542CrossRefPubMed Moore DC, Crisco JJ, Trafton TG, Leventhal EL (2007) A digital database of wrist bone anatomy and carpal kinematics. J Biomech 40(11):2537–2542CrossRefPubMed
17.
Zurück zum Zitat Myronenko A, Song X (2010) Point set registration: coherent point drift. IEEE Trans Pattern Anal Mach Intell 32(12):2262–2275CrossRefPubMed Myronenko A, Song X (2010) Point set registration: coherent point drift. IEEE Trans Pattern Anal Mach Intell 32(12):2262–2275CrossRefPubMed
18.
Zurück zum Zitat Nishihara R (2000) The dilemmas of a scaphoid fracture: a difficult diagnosis for primary care physicians. Hosp Physician 36(3):24–42 Nishihara R (2000) The dilemmas of a scaphoid fracture: a difficult diagnosis for primary care physicians. Hosp Physician 36(3):24–42
19.
Zurück zum Zitat Rasoulian A, Rohling R, Abolmaesumi P (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+ pose model. IEEE Trans Med Imaging 32(10):1890–1900CrossRefPubMed Rasoulian A, Rohling R, Abolmaesumi P (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+ pose model. IEEE Trans Med Imaging 32(10):1890–1900CrossRefPubMed
20.
Zurück zum Zitat Rhemrev SJ, Ootes D, Beeres FJ, Meylaerts SA, Schipper IB (2011) Current methods of diagnosis and treatment of scaphoid fractures. Int J Emerg Med 4:4. doi:10.1186/1865-1380-4-4 Rhemrev SJ, Ootes D, Beeres FJ, Meylaerts SA, Schipper IB (2011) Current methods of diagnosis and treatment of scaphoid fractures. Int J Emerg Med 4:4. doi:10.​1186/​1865-1380-4-4
21.
Zurück zum Zitat Smith EJ, Al-Sanawi HA, Gammon B, John PJS, Pichora DR, Ellis RE (2012) Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation. Int J Comput Assist Radiol Surg 7(3):433–444CrossRefPubMed Smith EJ, Al-Sanawi HA, Gammon B, John PJS, Pichora DR, Ellis RE (2012) Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation. Int J Comput Assist Radiol Surg 7(3):433–444CrossRefPubMed
22.
Zurück zum Zitat Tada K, Ikeda K, Okamoto S, Hachinota A, Yamamoto D, Tsuchiya H (2015) Scaphoid fracture-overview and conservative treatment. Hand Surg 20(02):204–209CrossRefPubMed Tada K, Ikeda K, Okamoto S, Hachinota A, Yamamoto D, Tsuchiya H (2015) Scaphoid fracture-overview and conservative treatment. Hand Surg 20(02):204–209CrossRefPubMed
23.
Zurück zum Zitat Trumble TE, Clarke T, Kreder HJ (1996) Non-union of the scaphoid: treatment with cannulated screws compared with treatment with herbert screws. J Bone Joint Surg 78(12):1829–1837PubMed Trumble TE, Clarke T, Kreder HJ (1996) Non-union of the scaphoid: treatment with cannulated screws compared with treatment with herbert screws. J Bone Joint Surg 78(12):1829–1837PubMed
Metadaten
Titel
Registration of a statistical model to intraoperative ultrasound for scaphoid screw fixation
verfasst von
Emran Mohammad Abu Anas
Alexander Seitel
Abtin Rasoulian
Paul St. John
Tamas Ungi
Andras Lasso
Kathryn Darras
David Wilson
Victoria A. Lessoway
Gabor Fichtinger
Michelle Zec
David Pichora
Parvin Mousavi
Robert Rohling
Purang Abolmaesumi
Publikationsdatum
01.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 6/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-016-1370-y

Weitere Artikel der Ausgabe 6/2016

International Journal of Computer Assisted Radiology and Surgery 6/2016 Zur Ausgabe

Guest Editorial

Preface