67. Retrofit of Air-Conditioning System in Data Center Using Separate Heat Pipe System

verfasst von : Yuwei Zheng, Zhen Li, Xiaohua Liu, Zhen Tong, Rang Tu

Erschienen in: Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Data center is developing quickly in China, which consumes much operating energy due to the 24 h operating annually. The energy consumption of air-conditioning (AC) system accounts for 40–50 % of the entire energy consumption in data center. There is large energy saving potential since the AC system operate annually even the outdoor environment is cold enough. The indoor thermal environment and energy utilization of a data center in Shanxi Province before and after retrofitting are tested during the July of 2012. The area of data center is 550 m2 and there are 145 cabinets. In the original design, eight typical air-cooled CRACs (computer room air conditioner) with total cooling capacity of 600 kW provide the required indoor climate. The original AC systems cannot meet the heat dissipation demand of all the cabinets, due to the reason that 14 cabinets with rather higher heat production of 3–8 kW. The total heat production of the 14 cabinets were accounting for 1/5 total heat production of the data center. The measured outlet temperatures of the 14 cabinets were over 30 °C. The retrofitting is focus on the aforementioned 14 cabinets, using separate heat pipe systems in the back-plane of cabinets which are accompanied by water chiller outdoor as cold source. The on-site measurements show that the retrofit separate heat pipe air-conditioning systems can meet the temperature requirement of safety operation of the high-density cabinet. The COP of AC system can reach 2.7. The entire energy consumption of AC systems after the retrofitting can reduce 18 % energy consumption in summer.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Chen X (2009) The feasibility analysis of air-conditioning energy saving project. South China University of Technology, Guangzhou Chen X (2009) The feasibility analysis of air-conditioning energy saving project. South China University of Technology, Guangzhou
2.
Zurück zum Zitat Cabusao G, Mochizuki M, Mashiko K et al (2010). Data center energy conservation utilizing a heat pipe based ice storage system. In: IEEE CPMT symposium japan (Formerly VLSI Packaging Workshop of Japan) Cabusao G, Mochizuki M, Mashiko K et al (2010). Data center energy conservation utilizing a heat pipe based ice storage system. In: IEEE CPMT symposium japan (Formerly VLSI Packaging Workshop of Japan)
3.
Zurück zum Zitat Qian XD, Li Z, Li ZX (2012) Experimental study on data center heat pipe air conditioning system. J Eng Thermophysics 33(7):1217–1220 Qian XD, Li Z, Li ZX (2012) Experimental study on data center heat pipe air conditioning system. J Eng Thermophysics 33(7):1217–1220
4.
Zurück zum Zitat Srinarayana N, Fakhim B, Behnia M et al (2012). A comparative study of raised-floor and hard-floor configurations in an air-cooled data centre. In: 13th IEEE interSociety conference on thermal and thermomechanical phenomena in electronic systems (ITherm), 2012, pp 43−50 Srinarayana N, Fakhim B, Behnia M et al (2012). A comparative study of raised-floor and hard-floor configurations in an air-cooled data centre. In: 13th IEEE interSociety conference on thermal and thermomechanical phenomena in electronic systems (ITherm), 2012, pp 43−50
5.
Zurück zum Zitat Zhang H, Zhuang J (2003) Research, development and industrial application of heat pipe technology in China. Appl Therm Eng 2003(23):1067–1083CrossRef Zhang H, Zhuang J (2003) Research, development and industrial application of heat pipe technology in China. Appl Therm Eng 2003(23):1067–1083CrossRef
6.
Zurück zum Zitat Lin S, Broadbent J, McGlen R (2005) Numerical study of heat pipe application in heat recovery systems. Appl Therm Eng 25(1):127–133CrossRef Lin S, Broadbent J, McGlen R (2005) Numerical study of heat pipe application in heat recovery systems. Appl Therm Eng 25(1):127–133CrossRef
7.
Zurück zum Zitat Wu XP, Mochizuki M, Mashiko K et al (2010) Energy conservation approach for data center cooling using heat pipe based cold energy storage system. In: 26th IEEE SEMI-THERM symposium Wu XP, Mochizuki M, Mashiko K et al (2010) Energy conservation approach for data center cooling using heat pipe based cold energy storage system. In: 26th IEEE SEMI-THERM symposium
8.
Zurück zum Zitat Fang G, Liu X, Wu S (2009) Experimental investigation on performance of ice storage air-conditioning system with separate heat pipe. Exp Thermal Fluid Sci 33:1149–1155CrossRef Fang G, Liu X, Wu S (2009) Experimental investigation on performance of ice storage air-conditioning system with separate heat pipe. Exp Thermal Fluid Sci 33:1149–1155CrossRef
Metadaten
Titel
Retrofit of Air-Conditioning System in Data Center Using Separate Heat Pipe System
verfasst von
Yuwei Zheng
Zhen Li
Xiaohua Liu
Zhen Tong
Rang Tu
Copyright-Jahr
2014
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-39581-9_67