Abstract

Permanent magnet (PM) synchronous motors with starting cage, already developed in the 1960s for variable-speed textile drives, become increasingly important as energy-efficient PM line-start motors. Differing from the standard design with integrated magnets, a rotor design with surface-mounted magnets is presented. In the planning and design phase of drives with PM line-start motors, the simulation of switching on, running up, and pulling into step is essential. An analytical model is presented leading to voltage and mechanical differential equations that have to be solved simultaneously. Based on a prototype, the suitability of the presented model is demonstrated by direct comparison of simulated to measured data. Besides, the mean influence factors of the pulling-into-step behavior are identified and discussed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Fischer R, Huth G (2011) Operational behavior of PM line-start motors with surface-mounted magnets. International ETG-Congress, Wuerzburg, ETG-Report 130:41–46 (in German) Fischer R, Huth G (2011) Operational behavior of PM line-start motors with surface-mounted magnets. International ETG-Congress, Wuerzburg, ETG-Report 130:41–46 (in German)
2.
Zurück zum Zitat Kim WH, Kim KC, Kim SJ et al (2009) A study on the optimal rotor design of LSPM considering the starting torque and efficiency. IEEE Trans Magn 45(3):1808–1811CrossRef Kim WH, Kim KC, Kim SJ et al (2009) A study on the optimal rotor design of LSPM considering the starting torque and efficiency. IEEE Trans Magn 45(3):1808–1811CrossRef
3.
Zurück zum Zitat Feng X, Liu L, Kang J, Zhang Y (2010) Super premium efficient line start-up permanent magnet synchronous motor. In: XIX International conference on electrical machines—ICEM, Rome Feng X, Liu L, Kang J, Zhang Y (2010) Super premium efficient line start-up permanent magnet synchronous motor. In: XIX International conference on electrical machines—ICEM, Rome
4.
Zurück zum Zitat Volkroth W (1962) Polradspannung, Reaktanzen und Ortskurve des Stromes der mit Dauermagneten erregten Synchronmaschine. ETZ Bd.83. Heft 16:517–522 Volkroth W (1962) Polradspannung, Reaktanzen und Ortskurve des Stromes der mit Dauermagneten erregten Synchronmaschine. ETZ Bd.83. Heft 16:517–522
5.
Zurück zum Zitat Honsinger VB (1980) Permanent magnet machines: asynchronous operation. IEEE Trans Power Appar Syst, PAS-99(4):1503–1509 Honsinger VB (1980) Permanent magnet machines: asynchronous operation. IEEE Trans Power Appar Syst, PAS-99(4):1503–1509
6.
Zurück zum Zitat Honsinger VB (1982) The fields and parameters of interior type AC permanent magnet machines. IEEE Trans Power Appar Syst, PAS-101:867–875 Honsinger VB (1982) The fields and parameters of interior type AC permanent magnet machines. IEEE Trans Power Appar Syst, PAS-101:867–875
7.
Zurück zum Zitat Fei W, Luk PCK (2009) A high-performance line-start permanent magnet synchronous motor amended from a small industrial three-phase induction motor. IEEE Trans Magn 45(10):4724–4727CrossRef Fei W, Luk PCK (2009) A high-performance line-start permanent magnet synchronous motor amended from a small industrial three-phase induction motor. IEEE Trans Magn 45(10):4724–4727CrossRef
8.
Zurück zum Zitat Kurihara K, Rahman A (2004) High-efficiency line-start interior permanent-magnet synchronous motors. IEEE Trans Ind Appl 40(3):789–796 Kurihara K, Rahman A (2004) High-efficiency line-start interior permanent-magnet synchronous motors. IEEE Trans Ind Appl 40(3):789–796
9.
Zurück zum Zitat Möller G (1988) Betriebsverhalten permanenterregter Synchronmotoren mit Luftspaltmagneten, Ph.D. dissertation, University of Hannover Möller G (1988) Betriebsverhalten permanenterregter Synchronmotoren mit Luftspaltmagneten, Ph.D. dissertation, University of Hannover
10.
Zurück zum Zitat Zhang B, Zhang W, Zhuang F, Feng G (2007) Design and starting process analysis of multipolar line-start PMSM. In: Proceeding of international conference on electrical machines and systems Oct. 8–11, Seoul, Korea, pp 1629–1634 Zhang B, Zhang W, Zhuang F, Feng G (2007) Design and starting process analysis of multipolar line-start PMSM. In: Proceeding of international conference on electrical machines and systems Oct. 8–11, Seoul, Korea, pp 1629–1634
11.
Zurück zum Zitat Brandes J (1989) Das Betriebsverhalten eines permanenterregten Synchronmotors mit anisotropem Läufer, Ph.D. dissertation, University of Hannover Brandes J (1989) Das Betriebsverhalten eines permanenterregten Synchronmotors mit anisotropem Läufer, Ph.D. dissertation, University of Hannover
12.
Zurück zum Zitat Patent document DE102009060438 (in German) Patent document DE102009060438 (in German)
13.
Zurück zum Zitat Huth G (1996) Slot cogging torque of permanent magnet ac-servomotors with a staggered rotor arrangement. Electr Eng 78:391–397 (in German)CrossRef Huth G (1996) Slot cogging torque of permanent magnet ac-servomotors with a staggered rotor arrangement. Electr Eng 78:391–397 (in German)CrossRef
14.
Zurück zum Zitat Huth G (1987) Transient current displacement in squirrel-cage bars described by numerical calculated equivalent circuits. Electr Eng 70:31–37 (in German) Huth G (1987) Transient current displacement in squirrel-cage bars described by numerical calculated equivalent circuits. Electr Eng 70:31–37 (in German)
Metadaten
Titel
Running up and pulling into step of PM line-start motors with surface-mounted magnets
verfasst von
Gerhard Huth
Ralf Fischer
Publikationsdatum
01.03.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Electrical Engineering / Ausgabe 1/2015
Print ISSN: 0948-7921
Elektronische ISSN: 1432-0487
DOI
https://doi.org/10.1007/s00202-014-0308-z

Weitere Artikel der Ausgabe 1/2015

Electrical Engineering 1/2015 Zur Ausgabe

Neuer Inhalt