Skip to main content

2018 | OriginalPaper | Buchkapitel

Single-Camera Vision-Based Vein Biometric Authentication and Heart Rate Monitoring via Infrared Imaging Analysis

verfasst von : Jae Hyun Han, Jinman Kim, Eui Chul Lee

Erschienen in: Advances in Computer Science and Ubiquitous Computing

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In this study, a feasibility test is performed to evaluate simultaneous heart rate measurement and individual identification via a single device. Thus, we have designed a novel device, comprising a modified webcam and 660 and 940 nm LEDs, as based on the principles of a conventional blood flow measurement sensor. To confirm the feasibility, we captured three types of images via respective employment of the following: 660 nm LEDs only, 940 nm LEDs only, and both 660 and 940 nm LEDs. A PPG (photoplethysmography) signal is acquired as the images are captured; the output is implemented as ground-truth data. Experimental results showed that the image analysis-based heart rate signal yields a pattern identical to that of a PPG signal. Additionally, acquired finger-vein image visibility and resolution is sufficient to perform finger-vein recognition. Testing the system using more than 100 subjects with variable health statuses confirmed that our proposed concept can be implemented as an effective heart rate monitoring system. The proposed method has the potential to significantly increase the efficiency of individual health information management.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Drinnan, M.J., Allen, J., Murray, A.: Relation between heart rate and pulse transit time during paced respiration. Physiol. Meas. 22(3), 425–432 (2001)CrossRef Drinnan, M.J., Allen, J., Murray, A.: Relation between heart rate and pulse transit time during paced respiration. Physiol. Meas. 22(3), 425–432 (2001)CrossRef
3.
Zurück zum Zitat Chiodi, H., Mohler, J.G.: Effects of exposure of blood hemoglobin to nitric oxide. Environ. Res. 37(2), 355–363 (1985)CrossRef Chiodi, H., Mohler, J.G.: Effects of exposure of blood hemoglobin to nitric oxide. Environ. Res. 37(2), 355–363 (1985)CrossRef
4.
Zurück zum Zitat Kelleher, J.F.: Pulse oximetry. J. Clin. Monit. Comput. 5(1), 37–62 (1989)CrossRef Kelleher, J.F.: Pulse oximetry. J. Clin. Monit. Comput. 5(1), 37–62 (1989)CrossRef
5.
Zurück zum Zitat Lee, E.C., Lee, H.C., Park, K.R.: Finger vein recognition by using minutiae based alignment and LBP based feature extraction. Int. J. Imaging Syst. Technol. 19, 179–186 (2009)CrossRef Lee, E.C., Lee, H.C., Park, K.R.: Finger vein recognition by using minutiae based alignment and LBP based feature extraction. Int. J. Imaging Syst. Technol. 19, 179–186 (2009)CrossRef
6.
Zurück zum Zitat Gonzalez, R.C., Woods, R.E.: Digital Image Processing. Prentice Hall, Englewood Cliffs (1992) Gonzalez, R.C., Woods, R.E.: Digital Image Processing. Prentice Hall, Englewood Cliffs (1992)
7.
Zurück zum Zitat Ahonen, T., Hadid, A., Pietikainen, M.: Face description with local binary patterns: application to face recognition. IEEE Trans. Pattern Anal. Mach. Intell. 28, 2037–2041 (2006)CrossRef Ahonen, T., Hadid, A., Pietikainen, M.: Face description with local binary patterns: application to face recognition. IEEE Trans. Pattern Anal. Mach. Intell. 28, 2037–2041 (2006)CrossRef
Metadaten
Titel
Single-Camera Vision-Based Vein Biometric Authentication and Heart Rate Monitoring via Infrared Imaging Analysis
verfasst von
Jae Hyun Han
Jinman Kim
Eui Chul Lee
Copyright-Jahr
2018
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-7605-3_208

Neuer Inhalt