Specifying Optimal Maintenance Factor in Internal Lighting Applications

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In the design of lighting applications, a maintenance factor (MF) is widely used when aggravation of lighting installation parameters should be taken into account. There are many publications offering guidelines for MF value selection. Most of them suppose that predefined maintenance plan already exists and recommendations for MF value selection are given based on that. In the reality that is not a common case and the designer embeds given MF into a project without adequate notion for that how the new lighting equipment will be actually exploited. The proper selection of MF requires definite arrangement of all exploitation measures affecting lighting parameters of the equipment. In the current work the MF value is derived from the optimal set of exploitation measures. The optimality is defined as a minimum of life time exploitation cost. The task for proper MF value selection is brought to an optimization problem and all considerations connected with that are discussed in details in the paper.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat CIE 097:2005 Maintenance of indoor electric lighting systems (2005) CIE 097:2005 Maintenance of indoor electric lighting systems (2005)
2.
Zurück zum Zitat EN12464-1 “Lighting of work places – Part 1: Indoor work places” EN12464-1 “Lighting of work places – Part 1: Indoor work places”
3.
Zurück zum Zitat Pacific Northwest National Laboratory, Lumen Maintenance and Light Loss Factors: Consequences of Current Design Practices for LEDs, Solid-State Lighting Program Building Technologies Program Office of Energy Efficiency and Renewable Energy U.S. Department of Energy, September 2013. http://www.pnnl.gov. Accessed 15 Mar 2017 Pacific Northwest National Laboratory, Lumen Maintenance and Light Loss Factors: Consequences of Current Design Practices for LEDs, Solid-State Lighting Program Building Technologies Program Office of Energy Efficiency and Renewable Energy U.S. Department of Energy, September 2013. http://​www.​pnnl.​gov. Accessed 15 Mar 2017
4.
Zurück zum Zitat Sanders, A.: Scott, Review of Illuminaiure Maintenance Factors. Mott Macdonald, December 2008 Sanders, A.: Scott, Review of Illuminaiure Maintenance Factors. Mott Macdonald, December 2008
5.
Zurück zum Zitat ETAP NV, The Maintenance Factor for Led Lighting, White paper, February 2013 ETAP NV, The Maintenance Factor for Led Lighting, White paper, February 2013
7.
Zurück zum Zitat Cree, Inc., Recommended Cree® ESA Series Indoor Luminaire Lumen Maintenance Factors (LMF) (2016). www.cree.com. Accessed 13 Jun 2017 Cree, Inc., Recommended Cree® ESA Series Indoor Luminaire Lumen Maintenance Factors (LMF) (2016). www.​cree.​com. Accessed 13 Jun 2017
9.
Zurück zum Zitat CIE 33.1-1996, “Depreciation of Installations and their Maintenance” CIE 33.1-1996, “Depreciation of Installations and their Maintenance”
Metadaten
Titel
Specifying Optimal Maintenance Factor in Internal Lighting Applications
verfasst von
Vultchan Gueorgiev
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-319-68321-8_38