7. Steel and Composite Structures

verfasst von : Anthony Abu, Ruoxi Shi, Mostafa Jafarian, Kevin LaMalva, Danny Hopkin

Erschienen in: International Handbook of Structural Fire Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This chapter examines structural fire engineering considerations that are specific to steel, which is a common construction material. First, thermal and mechanical properties of steel at elevated temperatures are discussed. Second, failure modes specific to steel structures (e.g. connection brittleness) are examined. Lastly, pertinent analysis techniques for structural fire engineering applications involving steel structures are presented. Notably, tensile membrane action theory is covered in depth, which is a mechanism that provides thin slabs with large load-bearing capacity, resulting from large vertical displacements, where induced radial tension in the centre of the slab (due to the large deflection) is resisted by a peripheral compression ring. Also, the performance of structural steel connections under fire conditions is closely examined. In the event of a fire, the global frame response is closely linked to the behaviour of such connections. When excessive axial and rotational deformations occur at high temperature, the connections need to be robust enough to provide structural integrity.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat CEN. (2005b). BS EN 1993-1-2 Eurocode 3: Design of steel structures - part 1–8: Design of joints. British Standards Institution. CEN. (2005b). BS EN 1993-1-2 Eurocode 3: Design of steel structures - part 1–8: Design of joints. British Standards Institution.
2.
Zurück zum Zitat American Institute of Steel Construction (AISC). (2016). AISC Standard 360-16, Appendix 4, Chicago, IL. American Institute of Steel Construction (AISC). (2016). AISC Standard 360-16, Appendix 4, Chicago, IL.
3.
Zurück zum Zitat ASCE/SEI 7-16: Minimum Design Loads and Associated Criteria for Buildings and Other Structures, American Society of Civil Engineers: Structural Engineering Institute, 2016. ASCE/SEI 7-16: Minimum Design Loads and Associated Criteria for Buildings and Other Structures, American Society of Civil Engineers: Structural Engineering Institute, 2016.
4.
Zurück zum Zitat Elghazouli, A., Cashell, K., & Izzuddin, B. (2009). Experimental evaluation of the mechanical properties of steel reinforcement at elevated temperature. Fire Safety Journal, 44(6), 909–919.CrossRef Elghazouli, A., Cashell, K., & Izzuddin, B. (2009). Experimental evaluation of the mechanical properties of steel reinforcement at elevated temperature. Fire Safety Journal, 44(6), 909–919.CrossRef
5.
Zurück zum Zitat Harmathy, T. (1967). A comprehensive creep model. Journal of Basic Engineering, 89(3), 496–502.CrossRef Harmathy, T. (1967). A comprehensive creep model. Journal of Basic Engineering, 89(3), 496–502.CrossRef
6.
Zurück zum Zitat Zhao, B., & Kruppa, J. (1997). Fire resistance of composite slabs with profiled steel sheet and of composite steel concrete beams Part 2: Composite beams. Final report EUR 16822. ISSN 10185593. Zhao, B., & Kruppa, J. (1997). Fire resistance of composite slabs with profiled steel sheet and of composite steel concrete beams Part 2: Composite beams. Final report EUR 16822. ISSN 10185593.
7.
Zurück zum Zitat Eurocode 1: Basis of Design and Actions on Structures, Part 1.2: Actions on Structures – Actions on Structures Exposed to Fire, ENV 1991-1-2, CEN, Brussels, Belgium, 2001. Eurocode 1: Basis of Design and Actions on Structures, Part 1.2: Actions on Structures – Actions on Structures Exposed to Fire, ENV 1991-1-2, CEN, Brussels, Belgium, 2001.
8.
Zurück zum Zitat CEN. (2005a). BS EN 1993-1-2 Eurocode 3: Design of steel structures - part 1–2: Actions on structures exposed to fire. British Standards Institution. CEN. (2005a). BS EN 1993-1-2 Eurocode 3: Design of steel structures - part 1–2: Actions on structures exposed to fire. British Standards Institution.
9.
Zurück zum Zitat Gardner, L., & Nethercot, D. A. (2011). Designers’ Guide to Eurocode 3, Thomas Telford, ISBN: 9780727741721 Gardner, L., & Nethercot, D. A. (2011). Designers’ Guide to Eurocode 3, Thomas Telford, ISBN: 9780727741721
10.
Zurück zum Zitat Phan, L. T., McAllister, T. P., Gross, J. L. and Hurley, M. J. (2010). Best Practice Guidelines for Structural Fire Resistance Design of Concrete and Steel Buildings NIST Technical note 1681. National Institute of Standards and Technology, Technology Administration, US Department of Commerce, Gaithersburg, MD Phan, L. T., McAllister, T. P., Gross, J. L. and Hurley, M. J. (2010). Best Practice Guidelines for Structural Fire Resistance Design of Concrete and Steel Buildings NIST Technical note 1681. National Institute of Standards and Technology, Technology Administration, US Department of Commerce, Gaithersburg, MD
11.
Zurück zum Zitat Ozyurt, E., & Wang, Y. C. (2015). Effects of truss behaviour on critical temperatures of welded steel tubular truss members exposed to uniform fire. Engineering Structures, 88, 225–240.CrossRef Ozyurt, E., & Wang, Y. C. (2015). Effects of truss behaviour on critical temperatures of welded steel tubular truss members exposed to uniform fire. Engineering Structures, 88, 225–240.CrossRef
12.
Zurück zum Zitat Ozyurt, E., & Wang, Y. C. (2016). Effects of non-uniform temperature distribution on critical member temperature of steel tubular truss. Engineering Structures, 116, 95–106.CrossRef Ozyurt, E., & Wang, Y. C. (2016). Effects of non-uniform temperature distribution on critical member temperature of steel tubular truss. Engineering Structures, 116, 95–106.CrossRef
13.
Zurück zum Zitat Chen, C. K., & Zhang, W. (2012). Comparative experimental investigation on steel staggered-truss constructed with different joints in fire. Journal of Constructional Steel Research, 77, 43–53.CrossRef Chen, C. K., & Zhang, W. (2012). Comparative experimental investigation on steel staggered-truss constructed with different joints in fire. Journal of Constructional Steel Research, 77, 43–53.CrossRef
14.
Zurück zum Zitat Lin, S. M., Du, Y. and Fu, J. X. (2014). Design strategies of fire safety for steel roof trusses exposed to localised fire. In 8th International conference on structures in fire, Shanghai, China (pp. 163–170) Lin, S. M., Du, Y. and Fu, J. X. (2014). Design strategies of fire safety for steel roof trusses exposed to localised fire. In 8th International conference on structures in fire, Shanghai, China (pp. 163–170)
15.
Zurück zum Zitat Newman, G. N., Robinson, J. T., & Bailey, C. G. (2006). Fire safe design: A new approach to multi-storey steel-framed buildings (2nd edn.), Steel Construction Institute Publication 288. Newman, G. N., Robinson, J. T., & Bailey, C. G. (2006). Fire safe design: A new approach to multi-storey steel-framed buildings (2nd edn.), Steel Construction Institute Publication 288.
16.
Zurück zum Zitat Newman, G., Robinson, J., and Bailey, C. G. (2000). ‘SCI P288 A new approach to multi-storey steel framed buildings’, Steel Construction Institute, Ascot, SCI P288. Newman, G., Robinson, J., and Bailey, C. G. (2000). ‘SCI P288 A new approach to multi-storey steel framed buildings’, Steel Construction Institute, Ascot, SCI P288.
17.
Zurück zum Zitat BSI. (1990a). Structural use of steelwork in building – Part 1: Code of practice for design in simple and continuous construction: hot rolled sections. British Standards Institute. BSI. (1990a). Structural use of steelwork in building – Part 1: Code of practice for design in simple and continuous construction: hot rolled sections. British Standards Institute.
18.
Zurück zum Zitat BSI. (1990b). Structural use of steelwork in building – Part 3: Design in composite construction. British Standards Institute. BSI. (1990b). Structural use of steelwork in building – Part 3: Design in composite construction. British Standards Institute.
19.
Zurück zum Zitat CEN (1994). Eurocode 4: Design of Composite Steel and Concrete Structures – Part 1.2: General Rules – Structural Fire Design (Draft), European Committee for Standardization. CEN (1994). Eurocode 4: Design of Composite Steel and Concrete Structures – Part 1.2: General Rules – Structural Fire Design (Draft), European Committee for Standardization.
20.
Zurück zum Zitat Foster, S., Chladna, M., Hsieh, C. B., & I and Plank, R. (2007). Thermal and structural behaviour of a full-scale composite building subject to a severe compartment fire. Fire Safety Journal, 42, 183–199.CrossRef Foster, S., Chladna, M., Hsieh, C. B., & I and Plank, R. (2007). Thermal and structural behaviour of a full-scale composite building subject to a severe compartment fire. Fire Safety Journal, 42, 183–199.CrossRef
21.
Zurück zum Zitat BSI. (2003). Structural use of steelwork in building—Part 8: Code of practice for fire resistant design. British Standards Institute. BSI. (2003). Structural use of steelwork in building—Part 8: Code of practice for fire resistant design. British Standards Institute.
22.
Zurück zum Zitat Huang, Z., Burgess, I. W., & Plank, R. J. (2002). Modelling of six full-scale fire tests on a composite building. The Structural Engineer, 80(19), 30–37. Huang, Z., Burgess, I. W., & Plank, R. J. (2002). Modelling of six full-scale fire tests on a composite building. The Structural Engineer, 80(19), 30–37.
23.
Zurück zum Zitat Martin, D. and Moore, D. (1999). The behaviour of multi-storey steel framed buildings in fire: A European Joint Research Programme. Cardington Test Report, prepared by British Steel Plc. Martin, D. and Moore, D. (1999). The behaviour of multi-storey steel framed buildings in fire: A European Joint Research Programme. Cardington Test Report, prepared by British Steel Plc.
25.
Zurück zum Zitat Lim, L. (2003). Membrane action in fire exposed concrete floor systems, PhD Thesis, University of Canterbury, New Zealand Lim, L. (2003). Membrane action in fire exposed concrete floor systems, PhD Thesis, University of Canterbury, New Zealand
26.
Zurück zum Zitat Abu, A. (2009). Behaviour of composite floor systems in fire. PhD thesis, University of Sheffield, UK Abu, A. (2009). Behaviour of composite floor systems in fire. PhD thesis, University of Sheffield, UK
27.
Zurück zum Zitat Bailey, C. G., & Moore, D. B. (2000). The structural behaviour of steel frames with composite floor slabs subject to fire – Part 1 Theory. The Structural Engineer, 78(11), 19–27. Bailey, C. G., & Moore, D. B. (2000). The structural behaviour of steel frames with composite floor slabs subject to fire – Part 1 Theory. The Structural Engineer, 78(11), 19–27.
28.
Zurück zum Zitat Bailey, C. G., & Moore, D. B. (2000). The structural behaviour of steel frames with composite floor slabs subject to fire – Part 2: Design. The Structural Engineer, 78(11), 28–33. Bailey, C. G., & Moore, D. B. (2000). The structural behaviour of steel frames with composite floor slabs subject to fire – Part 2: Design. The Structural Engineer, 78(11), 28–33.
29.
Zurück zum Zitat Hayes, B. (1968). Allowing for membrane action in the plastic analysis of rectangular reinforced concrete slabs. Magazine of Concrete Research, 20(65), 205–212.CrossRef Hayes, B. (1968). Allowing for membrane action in the plastic analysis of rectangular reinforced concrete slabs. Magazine of Concrete Research, 20(65), 205–212.CrossRef
30.
Zurück zum Zitat Bailey, C. G., & Toh, W. S. (2007). Behaviour of concrete floor slabs at ambient and elevated temperatures. Fire Safety Journal, 42, 425–436.CrossRef Bailey, C. G., & Toh, W. S. (2007). Behaviour of concrete floor slabs at ambient and elevated temperatures. Fire Safety Journal, 42, 425–436.CrossRef
31.
Zurück zum Zitat Duchow, M. and Abu, A. K. (2014). Collapse mechanisms of edge and corner slab panels in fire conditions. Proceedings of the 8th International Conference on Structures in Fire, 11–13 June 2014, Shanghai, China, pp. 335–342. Duchow, M. and Abu, A. K. (2014). Collapse mechanisms of edge and corner slab panels in fire conditions. Proceedings of the 8th International Conference on Structures in Fire, 11–13 June 2014, Shanghai, China, pp. 335–342.
32.
Zurück zum Zitat Bailey, C. G. (2000). Design of steel structures with composite slabs at the fire limit state, Final Report No. 81415, prepared for DETR and SCI, The Building Research Establishment, Garston, UK Bailey, C. G. (2000). Design of steel structures with composite slabs at the fire limit state, Final Report No. 81415, prepared for DETR and SCI, The Building Research Establishment, Garston, UK
33.
Zurück zum Zitat Bailey, C. G. (2001). Membrane action of unrestrained lightly reinforced concrete slabs at large displacements. Engineering Structures, 23, 470–483.CrossRef Bailey, C. G. (2001). Membrane action of unrestrained lightly reinforced concrete slabs at large displacements. Engineering Structures, 23, 470–483.CrossRef
34.
Zurück zum Zitat Bailey, C. G. (2003). Efficient arrangement of reinforcement for membrane behaviour of composite floors in fire conditions. Journal of Constructional Steel Research, 59, 931–949.CrossRef Bailey, C. G. (2003). Efficient arrangement of reinforcement for membrane behaviour of composite floors in fire conditions. Journal of Constructional Steel Research, 59, 931–949.CrossRef
35.
Zurück zum Zitat Bailey, C. G. (2004). Membrane action of slab/beam composite floor systems in fire. Engineering Structures, 26, 1691–1703.CrossRef Bailey, C. G. (2004). Membrane action of slab/beam composite floor systems in fire. Engineering Structures, 26, 1691–1703.CrossRef
36.
Zurück zum Zitat Clifton, C. (2001). “Design of multi-storey steel framed buildings with unprotected secondary beams or joists for dependable inelastic response in severe fires.” Steel Design and Construction Bulletin 60, New Zealand Heavy Engineering Research Association (HERA), 1–58 Clifton, C. (2001). “Design of multi-storey steel framed buildings with unprotected secondary beams or joists for dependable inelastic response in severe fires.” Steel Design and Construction Bulletin 60, New Zealand Heavy Engineering Research Association (HERA), 1–58
37.
Zurück zum Zitat Clifton, G. C. (2006). Design of composite steel floor systems for severe fires. HERA Report R4–131, Manukau City, Auckland. Clifton, G. C. (2006). Design of composite steel floor systems for severe fires. HERA Report R4–131, Manukau City, Auckland.
38.
Zurück zum Zitat Clifton, G. C., Gillies, A. G. and Mago N. (2010). The slab panel method: design of composite floor systems for dependable inelastic response to severe fires. Proceedings of the 6th International Conference on Structures in Fire (SiF’10), 2–4 June 2010, East Lansing, MI, USA, pp. 492–499 Clifton, G. C., Gillies, A. G. and Mago N. (2010). The slab panel method: design of composite floor systems for dependable inelastic response to severe fires. Proceedings of the 6th International Conference on Structures in Fire (SiF’10), 2–4 June 2010, East Lansing, MI, USA, pp. 492–499
39.
Zurück zum Zitat Taib, M., (2012). The performance of steel framed structures with fin-plate connections in fire, PhD Thesis: The University of Sheffield. Taib, M., (2012). The performance of steel framed structures with fin-plate connections in fire, PhD Thesis: The University of Sheffield.
40.
Zurück zum Zitat Nguyen, T., Tan, H., & Burgess, I. (2015). Behaviour of composite slab-beam systems at elevated temperatures: Experimental and numerical investigation. Engineering Structures, 82, 199–213.CrossRef Nguyen, T., Tan, H., & Burgess, I. (2015). Behaviour of composite slab-beam systems at elevated temperatures: Experimental and numerical investigation. Engineering Structures, 82, 199–213.CrossRef
41.
Zurück zum Zitat Buchanan, A. H., & Abu, A. (2017). Structural design for fire safety (2nd ed.). John Wiley & Sons. Buchanan, A. H., & Abu, A. (2017). Structural design for fire safety (2nd ed.). John Wiley & Sons.
42.
Zurück zum Zitat Huang, Z., Burgess, I. W., & Plank, R. J. (2000). Effective stiffness modelling of composite concrete slabs in fire. Engineering Structures, 22, 1133–1144.CrossRef Huang, Z., Burgess, I. W., & Plank, R. J. (2000). Effective stiffness modelling of composite concrete slabs in fire. Engineering Structures, 22, 1133–1144.CrossRef
43.
Zurück zum Zitat CEN (2005c). Eurocode 4: Design of composite steel and concrete structures—Part 1–2: General rules ‐ Structural fire design. EN 1994–1‐2. European Committee for Standardization, Brussels. CEN (2005c). Eurocode 4: Design of composite steel and concrete structures—Part 1–2: General rules ‐ Structural fire design. EN 1994–1‐2. European Committee for Standardization, Brussels.
46.
Zurück zum Zitat McAllister, T., Gann, R., Averill, J., Gross, J., Grosshandler, W., Lawson, J., McGrattan, K., Nelson, H., Pitts, W., Prasad, K., Sadek, F. (2008). Federal building and fire safety investigation of the world trade center disaster: Structural fire response and probable collapse sequence of world trade center building 7. NIST NCSTAR 1–9. National Institute of Standards and Technology, Gaithersburg, MD. McAllister, T., Gann, R., Averill, J., Gross, J., Grosshandler, W., Lawson, J., McGrattan, K., Nelson, H., Pitts, W., Prasad, K., Sadek, F. (2008). Federal building and fire safety investigation of the world trade center disaster: Structural fire response and probable collapse sequence of world trade center building 7. NIST NCSTAR 1–9. National Institute of Standards and Technology, Gaithersburg, MD.
47.
Zurück zum Zitat Davison, B., & Owens, G. (2012). Steel designers' manual (7th ed.). John Wiley & Sons. Davison, B., & Owens, G. (2012). Steel designers' manual (7th ed.). John Wiley & Sons.
48.
Zurück zum Zitat Al-Jarbri, K. (1999). The behaviour of steel and composite beam-to-column connections in fire, PhD thesis: The University of Sheffield. Al-Jarbri, K. (1999). The behaviour of steel and composite beam-to-column connections in fire, PhD thesis: The University of Sheffield.
49.
Zurück zum Zitat El-Rimawi, J., Burgess, I., & Plank, R. (1997). The influence of connection stiffness on the behaviour of steel beams in fire. Journal of Constructional, 43, 1–15. El-Rimawi, J., Burgess, I., & Plank, R. (1997). The influence of connection stiffness on the behaviour of steel beams in fire. Journal of Constructional, 43, 1–15.
50.
Zurück zum Zitat Leston-Jones, L. (1997). The influence of semi-rigid connections on the performance of steel framed structures in fire, PhD thesis: The University of Sheffield. Leston-Jones, L. (1997). The influence of semi-rigid connections on the performance of steel framed structures in fire, PhD thesis: The University of Sheffield.
51.
Zurück zum Zitat Shi, R. (2017). A simplified steel beam-to-column connection modelling approach and influence of connection ductility on frame behaviour in fire, PhD thesis: The University of Sheffield. Shi, R. (2017). A simplified steel beam-to-column connection modelling approach and influence of connection ductility on frame behaviour in fire, PhD thesis: The University of Sheffield.
52.
Zurück zum Zitat Yu, H.-X., Burgess, I., Davison, J. & Plank, R. (2008). Experimental investigation of the behaviour of flush end-plate connections in fire. Singapore, Proceedings of Structures in Fire Conference, pp. 150–157. Yu, H.-X., Burgess, I., Davison, J. & Plank, R. (2008). Experimental investigation of the behaviour of flush end-plate connections in fire. Singapore, Proceedings of Structures in Fire Conference, pp. 150–157.
53.
Zurück zum Zitat Al-Jarbri, K., Seibi, A., & Karrech, A. (2006). Modelling of unstiffened flush endplate bolted connections in fire. Journal of Constructional Steel Research, 62, 151–159.CrossRef Al-Jarbri, K., Seibi, A., & Karrech, A. (2006). Modelling of unstiffened flush endplate bolted connections in fire. Journal of Constructional Steel Research, 62, 151–159.CrossRef
54.
Zurück zum Zitat Augusto, H., Simoes da Silva, L., Rebelo, C., & Castro, J. (2016). Characterization of web panel components in double-extended bolted end-plate steel joints. Journal of Constructional Steel Research, 116, 271–293.CrossRef Augusto, H., Simoes da Silva, L., Rebelo, C., & Castro, J. (2016). Characterization of web panel components in double-extended bolted end-plate steel joints. Journal of Constructional Steel Research, 116, 271–293.CrossRef
55.
Zurück zum Zitat Dai, X., Wang, Y., & Bailey, C. (2010). Numerical modelling of structural fire behaviour of restrained steel beam-column assemblies using typical joint types. Engineering Structures, 32, 2337–2351.CrossRef Dai, X., Wang, Y., & Bailey, C. (2010). Numerical modelling of structural fire behaviour of restrained steel beam-column assemblies using typical joint types. Engineering Structures, 32, 2337–2351.CrossRef
56.
Zurück zum Zitat Haremza, C., et al. (2016). Composite joints under MN at elevated temperatures. Journal of Constructional Steel Research, 124, 173–186.CrossRef Haremza, C., et al. (2016). Composite joints under MN at elevated temperatures. Journal of Constructional Steel Research, 124, 173–186.CrossRef
57.
Zurück zum Zitat Liu, T. (1996). Finite element modelling of behaviours of steel beams and connections in fire. Journal of Constructional Steel Research, 36(3), 181–199.CrossRef Liu, T. (1996). Finite element modelling of behaviours of steel beams and connections in fire. Journal of Constructional Steel Research, 36(3), 181–199.CrossRef
58.
Zurück zum Zitat Liu, T. C. (1999). Moment-rotation-temperature characteristics of steel/composite connections. Journal of Structural Engineering, 125(10), 1188–1197.CrossRef Liu, T. C. (1999). Moment-rotation-temperature characteristics of steel/composite connections. Journal of Structural Engineering, 125(10), 1188–1197.CrossRef
59.
Zurück zum Zitat Sarraj, M., Burgess, I., Davison, J., & Plank, R. (2007). Finite element modelling of steel fin plate connections in fire. Fire Safety Journal, 42, 408–415.CrossRef Sarraj, M., Burgess, I., Davison, J., & Plank, R. (2007). Finite element modelling of steel fin plate connections in fire. Fire Safety Journal, 42, 408–415.CrossRef
60.
Zurück zum Zitat Selamet, S., & Garlock, M. (2014). Fire resistance of steel shear connections. Fire Safety Journal, 68, 52–60.CrossRef Selamet, S., & Garlock, M. (2014). Fire resistance of steel shear connections. Fire Safety Journal, 68, 52–60.CrossRef
61.
Zurück zum Zitat Spyrou, S. (2002). Development of a component-based model of steel beam-to-column joints at elevated temperatures, PhD thesis: The University of Sheffield. Spyrou, S. (2002). Development of a component-based model of steel beam-to-column joints at elevated temperatures, PhD thesis: The University of Sheffield.
62.
Zurück zum Zitat Tschemmernegg, F., & Humer, C. (1988). The Design of Structural-Steel Frames under consideration of the nonlinear behavior of joints. Journal of Constructional Steel Research, 11(2), 73–103.CrossRef Tschemmernegg, F., & Humer, C. (1988). The Design of Structural-Steel Frames under consideration of the nonlinear behavior of joints. Journal of Constructional Steel Research, 11(2), 73–103.CrossRef
63.
Zurück zum Zitat Block, F., Burgess, I., Davison, J. & Plank, R. (2004). A component approach to modelling steelwork connections in fire: behaviour of column webs in compression. Nashville, Tennessee, Proceedings of ASCE Structures Congress. Block, F., Burgess, I., Davison, J. & Plank, R. (2004). A component approach to modelling steelwork connections in fire: behaviour of column webs in compression. Nashville, Tennessee, Proceedings of ASCE Structures Congress.
64.
Zurück zum Zitat Block, F., Burgess, I., Davison, J., & Plank, R. (2007). The development of a component-based connection element for end-plate connections in fire. Fire Safety Journal, 42, 498–506.CrossRef Block, F., Burgess, I., Davison, J., & Plank, R. (2007). The development of a component-based connection element for end-plate connections in fire. Fire Safety Journal, 42, 498–506.CrossRef
65.
Zurück zum Zitat Dong, G., Burgess, I. & Davison, J. (2011). Component-Based Element for Endplate Connections in Fire. Prague, Proceedings of Application of Structural Fire Engineering, pp. 195–200. Dong, G., Burgess, I. & Davison, J. (2011). Component-Based Element for Endplate Connections in Fire. Prague, Proceedings of Application of Structural Fire Engineering, pp. 195–200.
66.
Zurück zum Zitat Dong, G., Burgess, I. & Davison, J. (2012). Application of a general component-based connection element in structural fire analysis. Qingdao, Proceedings of 11th Int. Conference on Steel, Space and Composite Structures. Dong, G., Burgess, I. & Davison, J. (2012). Application of a general component-based connection element in structural fire analysis. Qingdao, Proceedings of 11th Int. Conference on Steel, Space and Composite Structures.
67.
Zurück zum Zitat Dong, G., Burgess, I., Davison, J., & Sun, R.-R. (2015). Development of a general component-based connection element for structural fire engineering analysis. Journal of Structural Fire Engineering, 6(4), 247–253.CrossRef Dong, G., Burgess, I., Davison, J., & Sun, R.-R. (2015). Development of a general component-based connection element for structural fire engineering analysis. Journal of Structural Fire Engineering, 6(4), 247–253.CrossRef
68.
Zurück zum Zitat Gentili, F., Costa, R. & Simoes da Silva, L. (2014). Development of a simplified model for joints in steel structures. Aveiro, Proceedings of 9º Congresso Nacional de Mecânica Experimental. Gentili, F., Costa, R. & Simoes da Silva, L. (2014). Development of a simplified model for joints in steel structures. Aveiro, Proceedings of 9º Congresso Nacional de Mecânica Experimental.
69.
Zurück zum Zitat Hu, Y., Davison, J., Burgess, I., & Plank, R. (2009). Component modelling of flexible end-plate connections in fire. International Journal of Steel Structures, 9, 29–38.CrossRef Hu, Y., Davison, J., Burgess, I., & Plank, R. (2009). Component modelling of flexible end-plate connections in fire. International Journal of Steel Structures, 9, 29–38.CrossRef
70.
Zurück zum Zitat Ramli-Sulong, N., Elghazouli, A., Izzuddin, B., & Ajit, N. (2010). Modelling of beam-to-column connections at elevated temperature using the component method. Steel and Composite Structures, 10(1), 23–43.CrossRef Ramli-Sulong, N., Elghazouli, A., Izzuddin, B., & Ajit, N. (2010). Modelling of beam-to-column connections at elevated temperature using the component method. Steel and Composite Structures, 10(1), 23–43.CrossRef
71.
Zurück zum Zitat Shi, R., S-S, H., & JB, D. (2018). A simplified steel beam-to-column connection modelling approach and influence of connection ductility on frame behaviour in fire. International Journal of High-Rise Buildings, 7(4), 343–362. Shi, R., S-S, H., & JB, D. (2018). A simplified steel beam-to-column connection modelling approach and influence of connection ductility on frame behaviour in fire. International Journal of High-Rise Buildings, 7(4), 343–362.
72.
Zurück zum Zitat Simoes da Silva, L., Santiago, A., & Real, P. (2001). A component model for the behaviour of steel joints at elevated temperatures. Journal of Constructional, 57, 1169–1195. Simoes da Silva, L., Santiago, A., & Real, P. (2001). A component model for the behaviour of steel joints at elevated temperatures. Journal of Constructional, 57, 1169–1195.
73.
Zurück zum Zitat Sun, R., Burgess, I., Huang, Z., & Dong, G. (2015). Progressive failure modelling and ductility demand of steel beam-to-column connections in fire. Engineering Structures, 89, 66–78.CrossRef Sun, R., Burgess, I., Huang, Z., & Dong, G. (2015). Progressive failure modelling and ductility demand of steel beam-to-column connections in fire. Engineering Structures, 89, 66–78.CrossRef
74.
Zurück zum Zitat Yu, H.-X., Burgess, I., Davison, J., & Plank, R. (2009). Tying capacity of web cleat connections in fire, part 2: Development of component-based model. Engineering Structures, 31, 697–708.CrossRef Yu, H.-X., Burgess, I., Davison, J., & Plank, R. (2009). Tying capacity of web cleat connections in fire, part 2: Development of component-based model. Engineering Structures, 31, 697–708.CrossRef
75.
Zurück zum Zitat ASCE/SEI (2018). Manual of Practice No. 138: Structural Fire Engineering, American Society of Civil Engineers: Structural Engineering Institute, Reston, VA. ASCE/SEI (2018). Manual of Practice No. 138: Structural Fire Engineering, American Society of Civil Engineers: Structural Engineering Institute, Reston, VA.
76.
Zurück zum Zitat Franssen, J., & VilaReal, P. (2010). Fire design of steel structures, ECCS – European Convention for Steelwork, ISBN 978-9147-099-0 Franssen, J., & VilaReal, P. (2010). Fire design of steel structures, ECCS – European Convention for Steelwork, ISBN 978-9147-099-0
77.
Zurück zum Zitat EN 13381-8, Test methods or determining the contribution to the fire resistance of structural members: applied reactive protection to steel members, European Committee for Standardization, CEN, 2010. EN 13381-8, Test methods or determining the contribution to the fire resistance of structural members: applied reactive protection to steel members, European Committee for Standardization, CEN, 2010.
Metadaten
Titel
Steel and Composite Structures
verfasst von
Anthony Abu
Ruoxi Shi
Mostafa Jafarian
Kevin LaMalva
Danny Hopkin
Copyright-Jahr
2021
DOI
https://doi.org/10.1007/978-3-030-77123-2_7