Skip to main content

2015 | OriginalPaper | Buchkapitel

24. The Importance of connections in Seismic Regions: Full-Scale Testing of a 3-Storey Precast Concrete Building

verfasst von : Dionysios Bournas, Paolo Negro, Francisco Javier Molina

Erschienen in: Experimental Research in Earthquake Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In the framework of the SAFECAST Project, a full-scale three-storey precast building was subjected to a series of pseudodynamic (PsD) tests in the European Laboratory for Structural Assessment (ELSA). The mock-up was constructed in such a way that four different structural configurations could be investigated experimentally. Therefore, the behaviour of various parameters like the types of mechanical connections (traditional as well as innovative) and the presence or absence of shear walls along with the framed structure were investigated. The first PsD tests were conducted on a dual frame-wall precast system, where two precast shear wall units were connected to the mock up. The first test structure sustained the maximum earthquake for which it was designed with small horizontal deformations. In the second layout, the shear walls were disconnected from the structure, to test the building in its most typical configuration, namely with hinged beam-column connections by means of dowel bars (shear connectors). This configuration was quite flexible and suffered large deformations under the design level earthquake. An innovative connection system, embedded in the precast elements, was then activated to create emulative beamcolumn connections in the last two structural configurations. In particular, in the third layout the connectors were restrained only at the top floor, whereas in the fourth layout the connection system was activated in all beam-column joints. The PsD test results showed that, when activated at all the floors, the proposed connection system is quite effective as a means of implementing dry precast (quasi) emulative moment-resisting frames.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Bournas DA, Negro P, Molina FJ (2013) Pseudodynamic tests on a full-scale 3-storey precast concrete building: behavior of the mechanical connections and floor diaphragms. Elsevier Eng Struct 57:609–627 Bournas DA, Negro P, Molina FJ (2013) Pseudodynamic tests on a full-scale 3-storey precast concrete building: behavior of the mechanical connections and floor diaphragms. Elsevier Eng Struct 57:609–627
Zurück zum Zitat CEN European Standard (2005) EN 1998-3: Eurocode 8: design of structures for earthquake resistance-part 3: assessment and retrofitting of buildings. European Committee for Standardization, Brussels CEN European Standard (2005) EN 1998-3: Eurocode 8: design of structures for earthquake resistance-part 3: assessment and retrofitting of buildings. European Committee for Standardization, Brussels
Zurück zum Zitat Molina FJ, Magonette G, Pegon P, Zapico B (2011) Monitoring damping in pseudodynamic tests. J Earthq Eng 15(6):877–900CrossRef Molina FJ, Magonette G, Pegon P, Zapico B (2011) Monitoring damping in pseudodynamic tests. J Earthq Eng 15(6):877–900CrossRef
Zurück zum Zitat Negro P, Mola E, Ferrara L, Zhao B, Magonette G, Molina J (2007) Precast structures EC8: seismic behaviour of precast concrete structures with respect to EC8-contract N. G6RD-CT-2002-00857. Final report of the experimental activity of the Italo-Slovenian Group, p 190 Negro P, Mola E, Ferrara L, Zhao B, Magonette G, Molina J (2007) Precast structures EC8: seismic behaviour of precast concrete structures with respect to EC8-contract N. G6RD-CT-2002-00857. Final report of the experimental activity of the Italo-Slovenian Group, p 190
Zurück zum Zitat Negro P, Bournas DA, Molina FJ (2013) Pseudodynamic tests on a full-scale 3-storey precast concrete building: global response. Elsevier Eng Struct 57:594–608 Negro P, Bournas DA, Molina FJ (2013) Pseudodynamic tests on a full-scale 3-storey precast concrete building: global response. Elsevier Eng Struct 57:594–608
Zurück zum Zitat Olgiati M, Negro P, Colombo A (2010) Safecast project: definition and analysis of the three-storey precast buildings. In: Proc. of the 14th ECEE Olgiati M, Negro P, Colombo A (2010) Safecast project: definition and analysis of the three-storey precast buildings. In: Proc. of the 14th ECEE
Zurück zum Zitat Pegon P, Molina FJ, Magonette G (2008) Continuous pseudo-dynamic testing at ELSA. In Saouma VE, Sivaselvan MV (eds) Hybrid simulation: theory, implementation and applications. Taylor & Francis/Balkema Publishers, pp 79–88 Pegon P, Molina FJ, Magonette G (2008) Continuous pseudo-dynamic testing at ELSA. In Saouma VE, Sivaselvan MV (eds) Hybrid simulation: theory, implementation and applications. Taylor & Francis/Balkema Publishers, pp 79–88
Metadaten
Titel
The Importance of connections in Seismic Regions: Full-Scale Testing of a 3-Storey Precast Concrete Building
verfasst von
Dionysios Bournas
Paolo Negro
Francisco Javier Molina
Copyright-Jahr
2015
DOI
https://doi.org/10.1007/978-3-319-10136-1_24