Abstract

In this paper, we investigate the variation of the fetal heart rate as we approach delivery. The fetal heart rate is affected by several factors, including the uterine contractions, the amount of oxygen in blood, the sex of the fetus, etc. We isolate specific biochemical markers or other measurable characteristics and compare plots expressing the average fetal heart rate versus the time remaining until the delivery, for subjects with different values in these characteristics. Our motivation is to study the effect of different values, related to a biochemical marker or characteristic, on the heart rate of the fetus. One important observation that came out from this study is the increased discriminating power presented between different groups of subjects, appearing in the time period before the delivery, where the heart works under unusual pressure. In some cases, even though the average fetal heart rate associated to each group can not be discriminated during the early stages, the differentiation becomes possible before delivery, since the group that is expected to react better under pressure achieves to keep the heart rate in higher levels.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Alfirevic Z, Devane D, Gyte GM. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2006;19(3):CD006,066. Alfirevic Z, Devane D, Gyte GM. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2006;19(3):CD006,066.
2.
Zurück zum Zitat Almström H, Ekman G, Axelsson O, Ulmsten U, Cnattingius S, Maesel A, Maršal K, Årström K. Comparison of umbilical-artery velocimetry and cardiotocography for surveillance of small-for-gestational-age fetuses. The Lancet 1992;340(8825):936– 940.CrossRef Almström H, Ekman G, Axelsson O, Ulmsten U, Cnattingius S, Maesel A, Maršal K, Årström K. Comparison of umbilical-artery velocimetry and cardiotocography for surveillance of small-for-gestational-age fetuses. The Lancet 1992;340(8825):936– 940.CrossRef
3.
Zurück zum Zitat Amer-Wåhlin I, Hellsten C, Norén H, Hagberg H, Herbst A, Kjellmer I, Lilja H, Lindoff C, Månsson M., Mårtensson L., et al. Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a swedish randomised controlled trial. The Lancet 2001;358 (9281):534–538.CrossRef Amer-Wåhlin I, Hellsten C, Norén H, Hagberg H, Herbst A, Kjellmer I, Lilja H, Lindoff C, Månsson M., Mårtensson L., et al. Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a swedish randomised controlled trial. The Lancet 2001;358 (9281):534–538.CrossRef
4.
Zurück zum Zitat Argyri M, Gayraud N, Manis G. Fetal heart rate in the course of delivery: Vaginal and C-sections. Proceedings of 37th IEEE International Conference of the Engineering in Medicine and Biology Society. Milan, Italy; 2015. Argyri M, Gayraud N, Manis G. Fetal heart rate in the course of delivery: Vaginal and C-sections. Proceedings of 37th IEEE International Conference of the Engineering in Medicine and Biology Society. Milan, Italy; 2015.
5.
Zurück zum Zitat Gayraud N, Argiri M, Manis G. Analysis of intrapartum fetal heart rate according to umbilical arterial pH and age of mother. Proceedings of 14th Mediterranean Conference on Medical and Biological Engineering and Computing. Paphos, Cyprus; 2016. Gayraud N, Argiri M, Manis G. Analysis of intrapartum fetal heart rate according to umbilical arterial pH and age of mother. Proceedings of 14th Mediterranean Conference on Medical and Biological Engineering and Computing. Paphos, Cyprus; 2016.
6.
Zurück zum Zitat Chudáček V, Spilka J, Burša M, Jank ˚u P, Hruban L, Huptych M, Lhotská L. Open access intrapartum CTG database. BMC Pregnancy and Childbirth 2014;14(1):1. Chudáček V, Spilka J, Burša M, Jank ˚u P, Hruban L, Huptych M, Lhotská L. Open access intrapartum CTG database. BMC Pregnancy and Childbirth 2014;14(1):1.
7.
Zurück zum Zitat D’Aloja E, Müller M, Paribello F, Demontis R, Faa A. Neonatal asphyxia and forensic medicine. The Journal of Maternal-Fetal & Neonatal Medicine 2009;22(sup3):54–56.CrossRef D’Aloja E, Müller M, Paribello F, Demontis R, Faa A. Neonatal asphyxia and forensic medicine. The Journal of Maternal-Fetal & Neonatal Medicine 2009;22(sup3):54–56.CrossRef
8.
Zurück zum Zitat Dijxhoorn M, Visser G, Huisjes H, Fidler V, Touwen B. The relation between umbilical pH values and neonatal neurological morbidity in full term appropriate-for-years infants. Early Hum Dev 1985;11(1):33–42.CrossRef Dijxhoorn M, Visser G, Huisjes H, Fidler V, Touwen B. The relation between umbilical pH values and neonatal neurological morbidity in full term appropriate-for-years infants. Early Hum Dev 1985;11(1):33–42.CrossRef
9.
Zurück zum Zitat Georgieva A, Payne SJ, Moulden M, Redman CWG. Artificial neural networks applied to fetal monitoring in labour. Neural Comput & Applic 2013;22(1):85–93.CrossRef Georgieva A, Payne SJ, Moulden M, Redman CWG. Artificial neural networks applied to fetal monitoring in labour. Neural Comput & Applic 2013;22(1):85–93.CrossRef
10.
Zurück zum Zitat Gilstrap LC, Leveno KJ, Burris J, Williams ML, Little BB. Diagnosis of birth asphyxia on the basis of fetal pH, Apgar score, and newborn cerebral dysfunction. Am J Obstet Gynecol 1989;161(3):825–830.CrossRef Gilstrap LC, Leveno KJ, Burris J, Williams ML, Little BB. Diagnosis of birth asphyxia on the basis of fetal pH, Apgar score, and newborn cerebral dysfunction. Am J Obstet Gynecol 1989;161(3):825–830.CrossRef
11.
Zurück zum Zitat Goldberger AL, Amaral LA, Glass L, Hausdorff JM, Ivanov PC, Mark RG, Mietus JE, Moody GB, Peng CK, Stanley HE. Physiobank, physiotoolkit, and physionet components of a new research resource for complex physiologic signals. Circulation 2000;101(23):e215–e220.CrossRef Goldberger AL, Amaral LA, Glass L, Hausdorff JM, Ivanov PC, Mark RG, Mietus JE, Moody GB, Peng CK, Stanley HE. Physiobank, physiotoolkit, and physionet components of a new research resource for complex physiologic signals. Circulation 2000;101(23):e215–e220.CrossRef
12.
Zurück zum Zitat Habek D, Habek JC, Jugović D, Salihagić A. Intrauterine hypoxia and sudden infant death syndrome. Acta Medica Croatica: Casopis Hravatske Akademije Medicinskih Znanosti. 2001;56(3):109–18. Habek D, Habek JC, Jugović D, Salihagić A. Intrauterine hypoxia and sudden infant death syndrome. Acta Medica Croatica: Casopis Hravatske Akademije Medicinskih Znanosti. 2001;56(3):109–18.
13.
Zurück zum Zitat Hutter D, Kingdom J, Jaeggi E. Causes and mechanisms of intrauterine hypoxia and its impact on the fetal cardiovascular system: a review. International Journal of Pediatrics 2010;2010:401323. Hutter D, Kingdom J, Jaeggi E. Causes and mechanisms of intrauterine hypoxia and its impact on the fetal cardiovascular system: a review. International Journal of Pediatrics 2010;2010:401323.
14.
Zurück zum Zitat Kingdom JCP, Kaufmann P. Oxygen and placental villous development: origins of fetal hypoxia. Placenta 1997;18(8):613–621.CrossRef Kingdom JCP, Kaufmann P. Oxygen and placental villous development: origins of fetal hypoxia. Placenta 1997;18(8):613–621.CrossRef
15.
Zurück zum Zitat Murray E, Mark J. A guide to effective care in pregnancy and childbirth. Oxford: Universiry Press; 2000. Murray E, Mark J. A guide to effective care in pregnancy and childbirth. Oxford: Universiry Press; 2000.
16.
Zurück zum Zitat Nicolaides KH, Bilardo CM, Soothill PW, Campbell S. Absence of end diastolic frequencies in umbilical artery: a sign of fetal hypoxia and acidosis. BMJ: British Medical Journal 1988;297(6655):1026–1027.CrossRef Nicolaides KH, Bilardo CM, Soothill PW, Campbell S. Absence of end diastolic frequencies in umbilical artery: a sign of fetal hypoxia and acidosis. BMJ: British Medical Journal 1988;297(6655):1026–1027.CrossRef
17.
Zurück zum Zitat Ryan SM, Goldberger AL, Pincus SM, Mietus J, Lipsitz LA. Gender- and age-related differences in heart rate dynamics: Are women more complex than men? Journal of the American College of Cardiology 1994;24 (7):1700–1707.CrossRef Ryan SM, Goldberger AL, Pincus SM, Mietus J, Lipsitz LA. Gender- and age-related differences in heart rate dynamics: Are women more complex than men? Journal of the American College of Cardiology 1994;24 (7):1700–1707.CrossRef
18.
Zurück zum Zitat Melman S, et al. Simple: implementation of recommendations from international evidence-based guidelines on caesarean sections in the Netherlands. protocol for a controlled before and after study. Implementation Sci 2013;8(3). Melman S, et al. Simple: implementation of recommendations from international evidence-based guidelines on caesarean sections in the Netherlands. protocol for a controlled before and after study. Implementation Sci 2013;8(3).
19.
Zurück zum Zitat Signorini MG, Magenes G, Cerutti S, Arduini D. Linear and nonlinear parameters for the analysisof fetal heart rate signal from cardiotocographic recordings. IEEE Trans Biomed Eng 2003;50(3):365–374.CrossRef Signorini MG, Magenes G, Cerutti S, Arduini D. Linear and nonlinear parameters for the analysisof fetal heart rate signal from cardiotocographic recordings. IEEE Trans Biomed Eng 2003;50(3):365–374.CrossRef
20.
Zurück zum Zitat Spilka J, Chudácek V, Koucký M, Lhotská L, Huptych M, Janku P, Georgoulas GK, Stylios CD. Using nonlinear features for fetal heart rate classification. Biomed Signal Proc and Control 2012;7(4): 350–357.CrossRef Spilka J, Chudácek V, Koucký M, Lhotská L, Huptych M, Janku P, Georgoulas GK, Stylios CD. Using nonlinear features for fetal heart rate classification. Biomed Signal Proc and Control 2012;7(4): 350–357.CrossRef
21.
Zurück zum Zitat Sweha A, Hacker T, Nuovo J. Interpretation of the electronic fetal heart rate during labor. Am Fam Physician 1999;59(9):2487–2500. Sweha A, Hacker T, Nuovo J. Interpretation of the electronic fetal heart rate during labor. Am Fam Physician 1999;59(9):2487–2500.
Metadaten
Titel
The variation of fetal heart rhythm towards delivery
verfasst von
Nathalie T. H. Gayraud
George Manis
Publikationsdatum
07.12.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Health and Technology / Ausgabe 1/2017
Print ISSN: 2190-7188
Elektronische ISSN: 2190-7196
DOI
https://doi.org/10.1007/s12553-016-0160-4

Weitere Artikel der Ausgabe 1/2017

Health and Technology 1/2017 Zur Ausgabe