Abstract

The accurate measurement of filter load after a brake emissions dynamometer test is the core output of a laboratory test according to the proposed UN GTR 24 (ECE/TRANS/180/Add.24 – UN GTR No.24 – Laboratory Measurement of Brake Emissions for Light-Duty Vehicles. https://​unece.​org/​transport/​documents/​2023/​07/​standards/​un-gtr-no24-laboratory-measurement-brake-emissions-light-duty. Accessed 29 July 2023). Even though test facilities following the recommendations and requirements of the UN GTR 24 can claim compliance, the due diligence suggests the filter weighing process requires additional verifications, relying on published and peer-reviewed international standards. This work presents the application of additional evaluations considering the filters' behaviour, the weighing room, and the weighing process. Lastly, the paper elaborates on a limited-scope assessment of measurement uncertainty and level of detection by applying key elements of international standards (ISO 22514-7:2021 Statistical methods in process management – Capability and performance – Part 7: Capability of measurement processes. Standard, International Organization for Standardization, Geneva, CH and ISO 11843-3:2003 Capability of detection – Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used. Standard, International Organization for Standardization, Geneva, CH, respectively). To conduct this work, the test facility used a legacy test system and an automated dust generator injecting fine Arizona dust for the level of detection and the two-way ANOVA assessments. The measurements and assessments indicate it is feasible to meet the UN GTR 24 and (DIN EN 12341 Ambient air – Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter. Standard, German Institute for Standardization, Berlin, Germany) requirements with reasonable effort.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat ISO 22514-7:2021 Statistical methods in process management – Capability and performance – Part 7: Capability of measurement processes. Standard, International Organization for Standardization, Geneva, CH. ISO 22514-7:2021 Statistical methods in process management – Capability and performance – Part 7: Capability of measurement processes. Standard, International Organization for Standardization, Geneva, CH.
3.
Zurück zum Zitat ISO 11843-3:2003 Capability of detection – Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used. Standard, International Organization for Standardization, Geneva, CH. ISO 11843-3:2003 Capability of detection – Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used. Standard, International Organization for Standardization, Geneva, CH.
4.
Zurück zum Zitat DIN EN 12341 Ambient air – Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter. Standard, German Institute for Standardization, Berlin, Germany. DIN EN 12341 Ambient air – Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter. Standard, German Institute for Standardization, Berlin, Germany.
6.
Zurück zum Zitat ISO 12103-1:2016 Road vehicles – Test contaminants for filter evaluation – Part 1: Arizona test dust. Standard, International Organization for Standardization, Geneva, CH. ISO 12103-1:2016 Road vehicles – Test contaminants for filter evaluation – Part 1: Arizona test dust. Standard, International Organization for Standardization, Geneva, CH.
7.
Zurück zum Zitat VDA Volume 5 Measurement and Inspection Processes. Capability, Planning and Management, 3rd revised edition, July 2021, Verband der Automobilindustrie e.V. Qualitäts Management Center (VDA QMC), Berlin, Germany. VDA Volume 5 Measurement and Inspection Processes. Capability, Planning and Management, 3rd revised edition, July 2021, Verband der Automobilindustrie e.V. Qualitäts Management Center (VDA QMC), Berlin, Germany.
8.
Zurück zum Zitat ISO 22514-2:2017 Statistical methods in process management – Capability and performance – Part 2: Process capability and performance of time-dependent process models. Standard, International Organization for Standardization, Geneva, CH. ISO 22514-2:2017 Statistical methods in process management – Capability and performance – Part 2: Process capability and performance of time-dependent process models. Standard, International Organization for Standardization, Geneva, CH.
9.
Zurück zum Zitat ISO 11843-4:2003 Capability of detection – Part 4: Methodology for comparing the minimum detectable value with a given value Standard, International Organization for Standardization, Geneva, CH. ISO 11843-4:2003 Capability of detection – Part 4: Methodology for comparing the minimum detectable value with a given value Standard, International Organization for Standardization, Geneva, CH.
Metadaten
Titel
Uncertainty of PM2.5 and PM10 Sampling per EN12341 Applied to Brake Emissions Lab Measurements
verfasst von
Carlos Agudelo
Hartmut Niemann
Frederik Weis
Alejandro Hortet
Copyright-Jahr
2023
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-68167-1_10

Premium Partner