Skip to main content

2016 | OriginalPaper | Buchkapitel

Whether the High-Voltage Transmission Lines Have Enough Load Capacity After Wildfire

verfasst von : Tianzheng Wang, Zhen Tang, Xinwei Wang, Jinzhao Yang, Xiaogang Wu, Kechao Zhao, Chong Zuo, Weiyi Chen

Erschienen in: Proceedings of the 5th International Conference on Electrical Engineering and Automatic Control

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Wildfire which caused by a variety of reasons seriously affects the safe and stable operation of the high-voltage transmission lines, and the load capacity research of the high-voltage transmission lines after wildfire is particularly important. In the experiment, the average tensile force of three kinds of aluminum cable steel reinforced (ACSR), which are new, actually burned by wildfire and burned by simulated wildfire with firewood, respectively, is tested. The results show that the safety value of load capacity of the transmission lines is 15 kN. In the case where the horizontal span, height difference, and the maximum sag are known, the lowest point’s horizontal tension of arc sag of the high-voltage transmission lines can be calculated. If it does not exceed 15 kN, even if the transmission lines subjected to wildfire, load capacity is greater than the tension of transmission lines. So it can usually operate safely. If the lowest point’s horizontal tension exceeds 15 kN, in the process of design and installation of the high-voltage transmission lines, by properly increasing maximum arc sag of transmission lines, the tension of the lowest point of arc sag is not more than 15 kN.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Shao T (2003) Mechanical calculation on overhead transmission line, 2nd edn. China Power Press, Beijing Shao T (2003) Mechanical calculation on overhead transmission line, 2nd edn. China Power Press, Beijing
2.
Zurück zum Zitat Liu Q (2006) Analysis and calculation of transmission line unbalanced tensile force. Electr Power Autom Equip 26(1):93–95 Liu Q (2006) Analysis and calculation of transmission line unbalanced tensile force. Electr Power Autom Equip 26(1):93–95
3.
Zurück zum Zitat Zhou C, Rui X (2013) Model of rain-induced vibration of transmission line and numerical analysis. J Vib Shock 32(6):173–175 Zhou C, Rui X (2013) Model of rain-induced vibration of transmission line and numerical analysis. J Vib Shock 32(6):173–175
4.
Zurück zum Zitat Zhu K, Liu C, Ren X (2005) Analysis on dynamic tension of conductor under transmission line galloping. Electr Power 38(10):40–44 Zhu K, Liu C, Ren X (2005) Analysis on dynamic tension of conductor under transmission line galloping. Electr Power 38(10):40–44
5.
Zurück zum Zitat Lin X, Yan B, Liu Z, Chen Z (2009) Finite element simulation for windage yaw of 220 kV overhead transmission lines. Chin J Appl Mech 26(1):120–124 Lin X, Yan B, Liu Z, Chen Z (2009) Finite element simulation for windage yaw of 220 kV overhead transmission lines. Chin J Appl Mech 26(1):120–124
6.
Zurück zum Zitat The China Power Enterprise Federation (editor in chief) (2010) Code for design of 110 kV~750 kV overhead transmission line. China Planning Press, Beijing The China Power Enterprise Federation (editor in chief) (2010) Code for design of 110 kV~750 kV overhead transmission line. China Planning Press, Beijing
Metadaten
Titel
Whether the High-Voltage Transmission Lines Have Enough Load Capacity After Wildfire
verfasst von
Tianzheng Wang
Zhen Tang
Xinwei Wang
Jinzhao Yang
Xiaogang Wu
Kechao Zhao
Chong Zuo
Weiyi Chen
Copyright-Jahr
2016
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-48768-6_139

Neuer Inhalt