Skip to main content
Erschienen in:
Buchtitelbild

2013 | OriginalPaper | Buchkapitel

Wireless Sphygmomanometer with Data Encryption

verfasst von : Hsien-Ju Ko, Kang-Ming Chang

Erschienen in: Intelligent Technologies and Engineering Systems

Verlag: Springer New York

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A wireless physiological signal measurement system has been developed in which physiological signals can be transferred to a host server via a personal digital assistant (PDA) with wireless transmission using Bluetooth technology. The subject’s personal information is also included with a radio frequency identification (RFID) tag. Both DES and RSA algorithms have been used to encrypt all the measured data and the key of DES algorithm to preserve the measured signal data with high security. This system is especially useful in the care and nursing environment, with efficient and high-accuracy security data transmission.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Tachakra S, Wang XH, Istepanian RS, Song YH (2003) Mobile e-health: the unwired evolution of telemedicine. Telemed J E Health 9(3):247–257CrossRef Tachakra S, Wang XH, Istepanian RS, Song YH (2003) Mobile e-health: the unwired evolution of telemedicine. Telemed J E Health 9(3):247–257CrossRef
2.
Zurück zum Zitat Alshehab A, Kobayashi N, Ruiz J, Kikuchi R, Shimamoto S, Ishibashi H (2008) A study on intrabody communication for personal healthcare monitoring system. Telemed J E Health 14(8):851–857CrossRef Alshehab A, Kobayashi N, Ruiz J, Kikuchi R, Shimamoto S, Ishibashi H (2008) A study on intrabody communication for personal healthcare monitoring system. Telemed J E Health 14(8):851–857CrossRef
3.
Zurück zum Zitat Dittmar A, Axisa F, Delhomme G, Gehin C (2004) New concepts and technologies in home care and ambulatory monitoring. Stud Health Technol Inform 108:9–35 Dittmar A, Axisa F, Delhomme G, Gehin C (2004) New concepts and technologies in home care and ambulatory monitoring. Stud Health Technol Inform 108:9–35
4.
Zurück zum Zitat Lin CC, Chiu MJ, Hsiao CC, Lee RG, Tsai YS (2006) Wireless health care service system for elderly with dementia. IEEE Trans Inf Technol Biomed 10(4):696–704CrossRef Lin CC, Chiu MJ, Hsiao CC, Lee RG, Tsai YS (2006) Wireless health care service system for elderly with dementia. IEEE Trans Inf Technol Biomed 10(4):696–704CrossRef
5.
Zurück zum Zitat Anagnostaki AP, Pavlopoulos S, Kyriakou E, Koutsouris D (2002) A novel codification scheme based on the “VITAL” and “DICOM” standards for telemedicine applications. IEEE Trans Biomed Eng 49(12):1399–1411CrossRef Anagnostaki AP, Pavlopoulos S, Kyriakou E, Koutsouris D (2002) A novel codification scheme based on the “VITAL” and “DICOM” standards for telemedicine applications. IEEE Trans Biomed Eng 49(12):1399–1411CrossRef
6.
Zurück zum Zitat Panescu D (2008) Wireless communication systems for implantable medical devices, IEEE Eng Med Biol Mag 27(2):96–101CrossRef Panescu D (2008) Wireless communication systems for implantable medical devices, IEEE Eng Med Biol Mag 27(2):96–101CrossRef
7.
Zurück zum Zitat Chang KM (2009) Portable obstructive sleep apnea screening system using overnight ECG and a PDA-based wireless transmission system. Telemed J e-Health 15(4):353–361CrossRef Chang KM (2009) Portable obstructive sleep apnea screening system using overnight ECG and a PDA-based wireless transmission system. Telemed J e-Health 15(4):353–361CrossRef
8.
Zurück zum Zitat Kim DK, Yoo SK, Park IC, Choa M, Bae KY, Kim YD, Heo JH (2009) A mobile telemedicine system for remote consultation in cases of acute stroke. J Telemed Telecare 15(2):102–107CrossRef Kim DK, Yoo SK, Park IC, Choa M, Bae KY, Kim YD, Heo JH (2009) A mobile telemedicine system for remote consultation in cases of acute stroke. J Telemed Telecare 15(2):102–107CrossRef
9.
Zurück zum Zitat Hu F, Jiang M, Wagner M, Dong DC (2007) Privacy-preserving telecardiology sensor networks: toward a low-cost portable wireless hardware/software codesign. IEEE Trans Inf Technol Biomed 11(6):619–627CrossRef Hu F, Jiang M, Wagner M, Dong DC (2007) Privacy-preserving telecardiology sensor networks: toward a low-cost portable wireless hardware/software codesign. IEEE Trans Inf Technol Biomed 11(6):619–627CrossRef
11.
Zurück zum Zitat Bleumer G (1994) Security for decentralized health information systems. Int J Biomed Comput 35:139–145 Bleumer G (1994) Security for decentralized health information systems. Int J Biomed Comput 35:139–145
Metadaten
Titel
Wireless Sphygmomanometer with Data Encryption
verfasst von
Hsien-Ju Ko
Kang-Ming Chang
Copyright-Jahr
2013
Verlag
Springer New York
DOI
https://doi.org/10.1007/978-1-4614-6747-2_1

Neuer Inhalt