Skip to main content

2014 | OriginalPaper | Buchkapitel

3. Wireless System with Multianalyte Implantable Biotransducer

verfasst von : Christian Kotanen, Anthony Guiseppi-Elie

Erschienen in: Security and Privacy for Implantable Medical Devices

Verlag: Springer New York

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Wireless potentiostats are being developed and commercialized for use in the development of implantable electrochemical biosensors for the monitoring of physiological markers in a wide range of pathologies. The merits and drawbacks of the Pinnacle Technology 8151 dual potentiostat are investigated for use with a novel implantable biotransducer, the dual responsive MDEA 5037 of ABTECH Scientific. In a laboratory setting, the 8151 potentiostat maintained a steady and unbroken signal as far away as 75 ft (23 m) and, when unobstructed, up to 100 ft (30 m). The percentage error between the two channels was determined to be 6.4 (±0.3) and 0.7 (±0.1) for resistor-capacitor dummy cells (RC = 10 MΩ and 1 μF) and resistor dummy cells (R = 10 MΩ), respectively. The intrachannel variability may be too large for exacting analyte determinations.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Beach, R.D., et al., Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- and three-electrode biosensors. Instrumentation and Measurement, IEEE Transactions on, 2005. 54(1): p. 61–72.CrossRef Beach, R.D., et al., Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- and three-electrode biosensors. Instrumentation and Measurement, IEEE Transactions on, 2005. 54(1): p. 61–72.CrossRef
2.
Zurück zum Zitat Yi-Fan, L., H. Chun-Yueh, and L. Bin-Da. A Voltammetry Potentiostat Design for Large Dynamic Range Current Measurement. in Intelligent Computation and Bio-Medical Instrumentation (ICBMI), 2011 International Conference on. 2011. Yi-Fan, L., H. Chun-Yueh, and L. Bin-Da. A Voltammetry Potentiostat Design for Large Dynamic Range Current Measurement. in Intelligent Computation and Bio-Medical Instrumentation (ICBMI), 2011 International Conference on. 2011.
3.
Zurück zum Zitat Frey, A., et al. Digital potentiostat for electrochemical bio sensor chips. in ESSCIRC, 2010 Proceedings of the. 2010. Frey, A., et al. Digital potentiostat for electrochemical bio sensor chips. in ESSCIRC, 2010 Proceedings of the. 2010.
4.
Zurück zum Zitat Islam, A.B., et al. A digitally controllable current readout circuit and modulator unit for remote monitoring and biotelemetry applications. in Electrical and Computer Engineering (ICECE), 2010 International Conference on. 2010. Islam, A.B., et al. A digitally controllable current readout circuit and modulator unit for remote monitoring and biotelemetry applications. in Electrical and Computer Engineering (ICECE), 2010 International Conference on. 2010.
5.
Zurück zum Zitat Chun-Yueh, H., et al. A Portable Potentiostat with Molecularly Imprinted Polymeric Electrode for Dopamine Sensing. in Testing and Diagnosis, 2009. ICTD 2009. IEEE Circuits and Systems International Conference on. 2009. Chun-Yueh, H., et al. A Portable Potentiostat with Molecularly Imprinted Polymeric Electrode for Dopamine Sensing. in Testing and Diagnosis, 2009. ICTD 2009. IEEE Circuits and Systems International Conference on. 2009.
6.
Zurück zum Zitat Razzaghpour, M., et al. A highly-accurate low-power CMOS potentiostat for implantable biosensors. in Biomedical Circuits and Systems Conference (BioCAS), 2011 IEEE. 2011. Razzaghpour, M., et al. A highly-accurate low-power CMOS potentiostat for implantable biosensors. in Biomedical Circuits and Systems Conference (BioCAS), 2011 IEEE. 2011.
7.
Zurück zum Zitat Islam, A.B., et al. A potentiostat circuit for multiple implantable electrochemical sensors. in Electrical and Computer Engineering (ICECE), 2010 International Conference on. 2010. Islam, A.B., et al. A potentiostat circuit for multiple implantable electrochemical sensors. in Electrical and Computer Engineering (ICECE), 2010 International Conference on. 2010.
8.
Zurück zum Zitat Shuo, G., et al. Wireless powered implantable bio-sensor tag system-on-chip for continuous glucose monitoring. in Biomedical Circuits and Systems Conference (BioCAS), 2011 IEEE. 2011. Shuo, G., et al. Wireless powered implantable bio-sensor tag system-on-chip for continuous glucose monitoring. in Biomedical Circuits and Systems Conference (BioCAS), 2011 IEEE. 2011.
9.
Zurück zum Zitat Guiseppi-Elie, A., An implantable biochip to influence patient outcomes following trauma-induced hemorrhage. Analytical and Bioanalytical Chemistry, 2011. 399(1): p. 403–419.CrossRef Guiseppi-Elie, A., An implantable biochip to influence patient outcomes following trauma-induced hemorrhage. Analytical and Bioanalytical Chemistry, 2011. 399(1): p. 403–419.CrossRef
10.
Zurück zum Zitat Zhang, M., et al., A low power sensor signal processing circuit for implantable biosensor applications. Smart Materials & Structures, 2007. 16(2): p. 525–530.CrossRef Zhang, M., et al., A low power sensor signal processing circuit for implantable biosensor applications. Smart Materials & Structures, 2007. 16(2): p. 525–530.CrossRef
11.
Zurück zum Zitat Donlan, R.M. and J.W. Costerton, Biofilms: survival mechanisms of clinically relevant microorganisms. Clin. Microbiol. Rev., 2002. 15(2): p. 167–93.CrossRef Donlan, R.M. and J.W. Costerton, Biofilms: survival mechanisms of clinically relevant microorganisms. Clin. Microbiol. Rev., 2002. 15(2): p. 167–93.CrossRef
12.
Zurück zum Zitat Gotz, F., Staphylococcus and biofilms. Mol Microbiol, 2002. 43(6): p. 1367–1378.CrossRef Gotz, F., Staphylococcus and biofilms. Mol Microbiol, 2002. 43(6): p. 1367–1378.CrossRef
13.
Zurück zum Zitat Gordon, R.J. and F.D. Lowy, Pathogenesis of methicillin-resistant Staphylococcus aureus infection. Clinical Infectious Diseases, 2008. 46: p. S350-S359.CrossRef Gordon, R.J. and F.D. Lowy, Pathogenesis of methicillin-resistant Staphylococcus aureus infection. Clinical Infectious Diseases, 2008. 46: p. S350-S359.CrossRef
14.
Zurück zum Zitat Fung, H.B., J.Y. Chang, and S. Kuczynski, A practical guide to the treatment of complicated skin and soft tissue infections. Drugs, 2003. 63(14): p. 1459–80.CrossRef Fung, H.B., J.Y. Chang, and S. Kuczynski, A practical guide to the treatment of complicated skin and soft tissue infections. Drugs, 2003. 63(14): p. 1459–80.CrossRef
15.
Zurück zum Zitat Horan, T.C., et al., CDC definitions of nosocomial surgical site infections, 1992: a modification of CDC definitions of surgical wound infections. Infect Control Hosp Epidemiol, 1992. 13(10): p. 606–8.CrossRef Horan, T.C., et al., CDC definitions of nosocomial surgical site infections, 1992: a modification of CDC definitions of surgical wound infections. Infect Control Hosp Epidemiol, 1992. 13(10): p. 606–8.CrossRef
16.
Zurück zum Zitat Jawhara, S. and S. Mordon, In vivo imaging of bioluminescent Escherichia coli in a cutaneous wound infection model for evaluation of an antibiotic therapy. Antimicrobial agents and chemotherapy, 2004. 48(9): p. 3436–41.CrossRef Jawhara, S. and S. Mordon, In vivo imaging of bioluminescent Escherichia coli in a cutaneous wound infection model for evaluation of an antibiotic therapy. Antimicrobial agents and chemotherapy, 2004. 48(9): p. 3436–41.CrossRef
17.
Zurück zum Zitat Kirkland, K.B., et al., The impact of surgical-site infections in the 1990s: attributable mortality, excess length of hospitalization, and extra costs. Infect Control Hosp Epidemiol, 1999. 20(11): p. 725–30.MathSciNetCrossRef Kirkland, K.B., et al., The impact of surgical-site infections in the 1990s: attributable mortality, excess length of hospitalization, and extra costs. Infect Control Hosp Epidemiol, 1999. 20(11): p. 725–30.MathSciNetCrossRef
18.
Zurück zum Zitat Bratzler, D.W. and P.M. Houck, Antimicrobial prophylaxis for surgery: an advisory statement from the National Surgical Infection Prevention Project. Clin Infect Dis, 2004. 38(12): p. 1706–15.CrossRef Bratzler, D.W. and P.M. Houck, Antimicrobial prophylaxis for surgery: an advisory statement from the National Surgical Infection Prevention Project. Clin Infect Dis, 2004. 38(12): p. 1706–15.CrossRef
19.
Zurück zum Zitat Burke, J.P., Infection control - a problem for patient safety. N Engl J Med, 2003. 348(7): p. 651–6.CrossRef Burke, J.P., Infection control - a problem for patient safety. N Engl J Med, 2003. 348(7): p. 651–6.CrossRef
20.
Zurück zum Zitat Pharmacists, A.S.o.H.-S., ASHP therapeutic guidelines on antimicrobial prophylaxis in surgery. Am J Health-Syst Pharm., 1999. 56: p. 1839–88. Pharmacists, A.S.o.H.-S., ASHP therapeutic guidelines on antimicrobial prophylaxis in surgery. Am J Health-Syst Pharm., 1999. 56: p. 1839–88.
21.
Zurück zum Zitat Kotanen, C. and A. Guisepp-Elie, Physiological Status monitoring for glucose and lactate during the onset of hemorrhagic shock. American Society of Gravitational and Space Biology Bulletin, 2010. 23(2): p. 55–63. Kotanen, C. and A. Guisepp-Elie, Physiological Status monitoring for glucose and lactate during the onset of hemorrhagic shock. American Society of Gravitational and Space Biology Bulletin, 2010. 23(2): p. 55–63.
22.
Zurück zum Zitat Rahman, A.R.A., G. Justin, and A. Guiseppi-Elie, Towards an implantable biochip for glucose and lactate monitoring using microdisc electrode arrays (MDEAs). Biomedical Microdevices, 2009. 11(1): p. 75–85.CrossRef Rahman, A.R.A., G. Justin, and A. Guiseppi-Elie, Towards an implantable biochip for glucose and lactate monitoring using microdisc electrode arrays (MDEAs). Biomedical Microdevices, 2009. 11(1): p. 75–85.CrossRef
23.
Zurück zum Zitat Franceschetti, D.R. and J.R. Macdonald, Small-Signal A-C Response Theory for Electrochromic Thin Films. Journal of The Electrochemical Society, 1982. 129(8): p. 1754–1756.CrossRef Franceschetti, D.R. and J.R. Macdonald, Small-Signal A-C Response Theory for Electrochromic Thin Films. Journal of The Electrochemical Society, 1982. 129(8): p. 1754–1756.CrossRef
24.
Zurück zum Zitat Morita, H., et al., Long-term hypergravity induces plastic alterations in vestibulo-cardiovascular reflex in conscious rats. Neuroscience Letters, 2007. 412(3): p. 201–205.CrossRef Morita, H., et al., Long-term hypergravity induces plastic alterations in vestibulo-cardiovascular reflex in conscious rats. Neuroscience Letters, 2007. 412(3): p. 201–205.CrossRef
25.
Zurück zum Zitat Wahono, N., et al., Evaluation of permselective membranes for optimization of intracerebral amperometric glutamate biosensors. Biosensors and Bioelectronics, 2012. 33(1): p. 260–266.CrossRef Wahono, N., et al., Evaluation of permselective membranes for optimization of intracerebral amperometric glutamate biosensors. Biosensors and Bioelectronics, 2012. 33(1): p. 260–266.CrossRef
26.
Zurück zum Zitat Endo, H., et al., Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish. Biosensors and Bioelectronics, 2009. 24(5): p. 1417–1423.CrossRef Endo, H., et al., Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish. Biosensors and Bioelectronics, 2009. 24(5): p. 1417–1423.CrossRef
27.
Zurück zum Zitat Endo, H., et al., Wireless monitoring of blood glucose levels in flatfish with a needle biosensor. Fisheries Science, 2010. 76(4): p. 687–694.MathSciNetCrossRef Endo, H., et al., Wireless monitoring of blood glucose levels in flatfish with a needle biosensor. Fisheries Science, 2010. 76(4): p. 687–694.MathSciNetCrossRef
28.
Zurück zum Zitat Clarke, W.L., et al., Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience. Journal of diabetes science and technology, 2009. 3(5): p. 1031–8. Clarke, W.L., et al., Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience. Journal of diabetes science and technology, 2009. 3(5): p. 1031–8.
29.
Zurück zum Zitat Kotanen, C. and A. Guiseppi-Elie, Bioactive Electroconductive Hydrogels Yield Novel Biotransducers for Glucose. Macromolecular Symposia, 2012. Kotanen, C. and A. Guiseppi-Elie, Bioactive Electroconductive Hydrogels Yield Novel Biotransducers for Glucose. Macromolecular Symposia, 2012.
30.
Zurück zum Zitat Bard, A.J. and L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications. Second Edition ed2001, New York: John Wiley & Sons. Bard, A.J. and L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications. Second Edition ed2001, New York: John Wiley & Sons.
31.
Zurück zum Zitat Kumkar, V., et al., Vulnerabilities of Wireless Security protocols (WEP and WPA2). International Journal of Advanced Research in Computer Engineering & Technology (IJARCET), 2012. 1(2): p. 34–38. Kumkar, V., et al., Vulnerabilities of Wireless Security protocols (WEP and WPA2). International Journal of Advanced Research in Computer Engineering & Technology (IJARCET), 2012. 1(2): p. 34–38.
Metadaten
Titel
Wireless System with Multianalyte Implantable Biotransducer
verfasst von
Christian Kotanen
Anthony Guiseppi-Elie
Copyright-Jahr
2014
Verlag
Springer New York
DOI
https://doi.org/10.1007/978-1-4614-1674-6_3

Neuer Inhalt