A Low Cost Electrical Impedance Tomography (EIT) Instrumentation for Impedance Imaging of Practical Phantoms: A Laboratory Study

Authors : Tushar Kanti Bera, J. Nagaraju

Published in: Proceedings of the Third International Conference on Soft Computing for Problem Solving

Publisher: Springer India

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

A low cost Electrical Impedance Tomography (EIT) instrumentation is developed for studying the impedance imaging of practical phantoms. The EIT instrumentation is developed with a constant current injector, signal conditioner block and a DIP switch based multiplexer module. The constant current injector consists of a variable frequency Voltage Controlled Oscillator (VCO) and a modified Howland based Voltage Control Current Source (VCCS). The signal conditioner block is made up of an instrumentation amplifier (IAmp), a 50 Hz notch filter (NF) and a narrow band pass filter (NBPF) developed by cascading one lowpass filter and a highpass filter. The electrode switching module is developed using DIP switch based multiplexers to switch the electrodes sequentially for injecting current and measuring the boundary voltage data. Load response, frequency response and the Fast Fourier Transform (FFT) studies are conducted to evaluate the VCO, VCCS, IAmp, NF and NBPF performance. A number of practical phantoms are developed and the resistivity imaging is studied in EIDORS to evaluate the instrumentation. Result shows that the instrumentation is suitable for laboratory based practical phantom imaging studies.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Webster, J.G.: Electrical Impedance Tomography. Adam Hilger Series of Biomedical Engineering. Adam Hilger, New York (1990) Webster, J.G.: Electrical Impedance Tomography. Adam Hilger Series of Biomedical Engineering. Adam Hilger, New York (1990)
2.
go back to reference Holder, D.S.: Electrical Impedance Tomography: Methods, History And Applications. Series in Medical Physics and Biomedical Engineering. Institute of Physics Publishing Ltd. (2005) Holder, D.S.: Electrical Impedance Tomography: Methods, History And Applications. Series in Medical Physics and Biomedical Engineering. Institute of Physics Publishing Ltd. (2005)
3.
go back to reference Bera, T.K., Nagaraju, J.: Electrical Impedance Tomography (EIT): A Harmless Medical Imaging Modality. Research Developments in Computer Vision and Image Processing: Methodologies and Applications, Chap. 13, pp 224–262, IGI Global, USA Bera, T.K., Nagaraju, J.: Electrical Impedance Tomography (EIT): A Harmless Medical Imaging Modality. Research Developments in Computer Vision and Image Processing: Methodologies and Applications, Chap. 13, pp 224–262, IGI Global, USA
4.
go back to reference Bera, T.K., Nagaraju, J.: Sensors for electrical impedance tomography. In: Webster, J.G. (ed.) The Measurement, Instrumentation, and Sensors Handbook, 2nd Edn, Chap. 61, pp 61-1–61-30. CRC Press, Boca Raton (2014) Bera, T.K., Nagaraju, J.: Sensors for electrical impedance tomography. In: Webster, J.G. (ed.) The Measurement, Instrumentation, and Sensors Handbook, 2nd Edn, Chap. 61, pp 61-1–61-30. CRC Press, Boca Raton (2014)
6.
go back to reference Bera, T.K., Nagaraju, J.: Studying the resistivity imaging of chicken tissue phantoms with different current patterns in electrical impedance tomography (EIT). Measurement 45, 663–682 (2012)CrossRef Bera, T.K., Nagaraju, J.: Studying the resistivity imaging of chicken tissue phantoms with different current patterns in electrical impedance tomography (EIT). Measurement 45, 663–682 (2012)CrossRef
7.
go back to reference Bera, T.K., Nagaraju, J.: Studies on the thin film based flexible gold electrode arrays for resistivity imaging in electrical impedance tomography. Measurement 47, 264–286, Impact Factor: 1.130 (2014) Bera, T.K., Nagaraju, J.: Studies on the thin film based flexible gold electrode arrays for resistivity imaging in electrical impedance tomography. Measurement 47, 264–286, Impact Factor: 1.130 (2014)
8.
go back to reference Bera, T.K., Nagaraju, J.: A multifrequency electrical impedance tomography (EIT) system for biomedical imaging. In: International Conference on Signal Processing and Communications (SPCOM 2012), India, IISc, Bangalore, Karnataka, India, pp. 1–5 Bera, T.K., Nagaraju, J.: A multifrequency electrical impedance tomography (EIT) system for biomedical imaging. In: International Conference on Signal Processing and Communications (SPCOM 2012), India, IISc, Bangalore, Karnataka, India, pp. 1–5
9.
go back to reference Seo, J.K., Woo, E.J.: Nonlinear inverse problem in imaging. Wiley, New York (2012) Seo, J.K., Woo, E.J.: Nonlinear inverse problem in imaging. Wiley, New York (2012)
10.
go back to reference Brown, B.H.: Electrical impedance tomography (EIT): a review. J. Med. Eng. Technol. 27(3), 97–108 (2003) Brown, B.H.: Electrical impedance tomography (EIT): a review. J. Med. Eng. Technol. 27(3), 97–108 (2003)
11.
go back to reference Bera, T.K., Nagaraju, J.: Studying the boundary data profile of a practical phantom for medical electrical impedance tomography with different electrode geometries. In: Dössel, O., Schlegel, W.C. (eds.) Proceedings of the World Congress on Medical Physics and Biomedical Engineering. Munich, Germany, WC 2009, IFMBE Proceedings 25/II, pp. 925–929 (2009) Bera, T.K., Nagaraju, J.: Studying the boundary data profile of a practical phantom for medical electrical impedance tomography with different electrode geometries. In: Dössel, O., Schlegel, W.C. (eds.) Proceedings of the World Congress on Medical Physics and Biomedical Engineering. Munich, Germany, WC 2009, IFMBE Proceedings 25/II, pp. 925–929 (2009)
12.
go back to reference Yorkey, T.J.: Comparing reconstruction methods for electrical impedance tomography. PhD thesis, University of Wisconsin at Madison, Madison, WI 53706 (1986) Yorkey, T.J.: Comparing reconstruction methods for electrical impedance tomography. PhD thesis, University of Wisconsin at Madison, Madison, WI 53706 (1986)
13.
go back to reference Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Improving conductivity image quality using block matrix-based multiple regularization (BMMR) technique in EIT: a simulation study. J. Electr. Bioimpedance 2, 33–47 (2011) Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Improving conductivity image quality using block matrix-based multiple regularization (BMMR) technique in EIT: a simulation study. J. Electr. Bioimpedance 2, 33–47 (2011)
14.
go back to reference Lionheart, W.R.B.: EIT reconstruction algorithms: pitfalls, challenges and recent developments. Physiol. Meas. 25, 125–142 (2004). Review articleCrossRef Lionheart, W.R.B.: EIT reconstruction algorithms: pitfalls, challenges and recent developments. Physiol. Meas. 25, 125–142 (2004). Review articleCrossRef
15.
go back to reference Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Improving image quality in electrical impedance tomography (EIT) using projection error propagation-based regularization (PEPR) technique: a simulation study. J. Electr. Bioimpedance 2, 2–12 (2011) Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Improving image quality in electrical impedance tomography (EIT) using projection error propagation-based regularization (PEPR) technique: a simulation study. J. Electr. Bioimpedance 2, 2–12 (2011)
16.
go back to reference Jing, L., Liu, S., Zhihong, L., Meng, S.: An image reconstruction algorithm based on the extended Tikhonov regularization method for electrical capacitance tomography. Measurement 42(3), 368–376 (2009)CrossRef Jing, L., Liu, S., Zhihong, L., Meng, S.: An image reconstruction algorithm based on the extended Tikhonov regularization method for electrical capacitance tomography. Measurement 42(3), 368–376 (2009)CrossRef
17.
go back to reference Bera, T.K., Nagaraju, J.: A simple instrumentation calibration technique for electrical impedance tomography (EIT) using a 16 electrode phantom. In: The fifth annual IEEE conference on automation science and engineering (IEEE CASE), India, pp. 347–352 (2009) Bera, T.K., Nagaraju, J.: A simple instrumentation calibration technique for electrical impedance tomography (EIT) using a 16 electrode phantom. In: The fifth annual IEEE conference on automation science and engineering (IEEE CASE), India, pp. 347–352 (2009)
18.
go back to reference Teniou, S., Meribout, M.: A new hierarchical reconstruction algorithm for electrical capacitance tomography using a relaxation region-based approach. Measurement 45(4), 683–690 (2012)CrossRef Teniou, S., Meribout, M.: A new hierarchical reconstruction algorithm for electrical capacitance tomography using a relaxation region-based approach. Measurement 45(4), 683–690 (2012)CrossRef
19.
go back to reference Bera, T.K., Nagaraju, J.: A multifrequency constant current source for medical electrical impedance tomography. In: Proceedings of the IEEE international conference on systems in medicine and biology. Kharagpur, India, pp. 278–283 (2010) Bera, T.K., Nagaraju, J.: A multifrequency constant current source for medical electrical impedance tomography. In: Proceedings of the IEEE international conference on systems in medicine and biology. Kharagpur, India, pp. 278–283 (2010)
20.
go back to reference Soleimani, M.: Electrical impedance tomography system: an open access circuit design. BioMed. Eng. (OnLine) 5(28), 1–8 (2006) Soleimani, M.: Electrical impedance tomography system: an open access circuit design. BioMed. Eng. (OnLine) 5(28), 1–8 (2006)
21.
go back to reference Bera, T.K., Nagaraju, J.: Surface electrode switching of a 16-electrode wireless EIT system using RF-based digital data transmission scheme with 8 channel encoder/decoder ICs. Measurement 45, 541–555 (2012)CrossRef Bera, T.K., Nagaraju, J.: Surface electrode switching of a 16-electrode wireless EIT system using RF-based digital data transmission scheme with 8 channel encoder/decoder ICs. Measurement 45, 541–555 (2012)CrossRef
22.
go back to reference Oh, T.I., Wi, H., Kim, D.Y., Yoo, P.J., Woo, E.J.: A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2. Physiol. Meas. 32, 835 Oh, T.I., Wi, H., Kim, D.Y., Yoo, P.J., Woo, E.J.: A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2. Physiol. Meas. 32, 835
23.
go back to reference Bera, T.K., Nagaraju, J.: Switching of a sixteen electrode array for wireless eit system using a RF-based 8-bit digital data transmission technique. In: Communications in Computer and Information Science, Part I, CCIS 269, pp. 202–211. Springer, Berlin (2012) Bera, T.K., Nagaraju, J.: Switching of a sixteen electrode array for wireless eit system using a RF-based 8-bit digital data transmission technique. In: Communications in Computer and Information Science, Part I, CCIS 269, pp. 202–211. Springer, Berlin (2012)
24.
go back to reference Bera, T.K., Nagaraju, J.: Switching of the surface electrodes array in A 16-electrode EIT system using 8-bit parallel digital data. In: IEEE World Congress on Information and Communication Technologies, Mumbai, India, pp. 1288–1293 (2011) Bera, T.K., Nagaraju, J.: Switching of the surface electrodes array in A 16-electrode EIT system using 8-bit parallel digital data. In: IEEE World Congress on Information and Communication Technologies, Mumbai, India, pp. 1288–1293 (2011)
25.
go back to reference Holder, D.S., Hanquan, Y., Rao, A.: Some practical biological phantoms for calibrating multifrequency electrical impedance tomography. Physiol. Meas. 17, A167–A177 (1996)CrossRef Holder, D.S., Hanquan, Y., Rao, A.: Some practical biological phantoms for calibrating multifrequency electrical impedance tomography. Physiol. Meas. 17, A167–A177 (1996)CrossRef
26.
go back to reference Bera, T.K., Nagaraju, J.: A chicken tissue phantom for studying an electrical impedance tomography (EIT) system suitable for clinical imaging. Sens. Imaging: Int. J. 12(3–4), 95–116 Bera, T.K., Nagaraju, J.: A chicken tissue phantom for studying an electrical impedance tomography (EIT) system suitable for clinical imaging. Sens. Imaging: Int. J. 12(3–4), 95–116
27.
go back to reference Sperandio, M., Guermandi, M., Guerrieri, R.: A four-shell diffusion phantom of the head for electrical impedance tomography. IEEE Trans. Biomed. Eng. 59(2), 383–389 (2012)CrossRef Sperandio, M., Guermandi, M., Guerrieri, R.: A four-shell diffusion phantom of the head for electrical impedance tomography. IEEE Trans. Biomed. Eng. 59(2), 383–389 (2012)CrossRef
28.
go back to reference Bera, T.K., Nagaraju, J.: Resistivity imaging of a reconfigurable phantom with circular inhomogeneities in 2D-electrical impedance tomography. Measurement 44(3), 518–526 (2011)CrossRef Bera, T.K., Nagaraju, J.: Resistivity imaging of a reconfigurable phantom with circular inhomogeneities in 2D-electrical impedance tomography. Measurement 44(3), 518–526 (2011)CrossRef
29.
go back to reference Kimoto, A., Shida, K.: Imaging of temperature-change distribution in the brain phantom by means of capacitance measurement. IEEE Trans. Instrum. Meas. 49(3) (2000) Kimoto, A., Shida, K.: Imaging of temperature-change distribution in the brain phantom by means of capacitance measurement. IEEE Trans. Instrum. Meas. 49(3) (2000)
30.
go back to reference Bera, T.K., Nagaraju, J.: A reconfigurable practical phantom for studying the 2D electrical impedance tomography (EIT) using a fem based forward solver. In: 10th International Conference on Biomedical Applications of Electrical Impedance Tomography (EIT 2009), Manchester, UK (2009) Bera, T.K., Nagaraju, J.: A reconfigurable practical phantom for studying the 2D electrical impedance tomography (EIT) using a fem based forward solver. In: 10th International Conference on Biomedical Applications of Electrical Impedance Tomography (EIT 2009), Manchester, UK (2009)
31.
go back to reference Bera, T.K., Nagaraju, J.: A study of practical biological phantoms with simple instrumentation for electrical impedance tomography (EIT). In: Proceedings of IEEE International Instrumentation and Measurement Technology Conference (I2MTC2009), Singapore, pp. 511–516 (2009) Bera, T.K., Nagaraju, J.: A study of practical biological phantoms with simple instrumentation for electrical impedance tomography (EIT). In: Proceedings of IEEE International Instrumentation and Measurement Technology Conference (I2MTC2009), Singapore, pp. 511–516 (2009)
32.
go back to reference Bera, T.K., Nagaraju, J.: A simple instrumentation calibration technique for electrical impedance tomography (EIT) using a 16 electrode phantom. In: 5th Annual IEEE Conference on Automation Science and Engineering, Bangalore, pp. 347–352 (2009) Bera, T.K., Nagaraju, J.: A simple instrumentation calibration technique for electrical impedance tomography (EIT) using a 16 electrode phantom. In: 5th Annual IEEE Conference on Automation Science and Engineering, Bangalore, pp. 347–352 (2009)
33.
go back to reference Bera, T.K., Nagaraju, J.: A stainless steel electrode phantom to study the forward problem of electrical impedance tomography (EIT). Sens. Transducers J. 104(5), 33–40 (2009) Bera, T.K., Nagaraju, J.: A stainless steel electrode phantom to study the forward problem of electrical impedance tomography (EIT). Sens. Transducers J. 104(5), 33–40 (2009)
34.
go back to reference Wang, M., Ma, Y., Holliday, N., Dai, Y., Williams, R.A., Lucas, G.: A high-performance EIT system. IEEE Sens. J. 5(2), 289 (2005) Wang, M., Ma, Y., Holliday, N., Dai, Y., Williams, R.A., Lucas, G.: A high-performance EIT system. IEEE Sens. J. 5(2), 289 (2005)
35.
go back to reference Goharian, M., Soleimani, M., Jegatheesan, A., Chin, K., Moran, G.R.: A DSP based multi-frequency 3D electrical impedance tomography system. Ann. Biomed. Eng. 36(9), 1594–1603 (2008) Goharian, M., Soleimani, M., Jegatheesan, A., Chin, K., Moran, G.R.: A DSP based multi-frequency 3D electrical impedance tomography system. Ann. Biomed. Eng. 36(9), 1594–1603 (2008)
36.
go back to reference Casas, O., Rosell, J., Brag′os, R., Lozano, A., Riu, P.J.: A parallel broadband real-time system for electrical impedance tomography. Physiol. Meas. 17, A1–A6 (1996)CrossRef Casas, O., Rosell, J., Brag′os, R., Lozano, A., Riu, P.J.: A parallel broadband real-time system for electrical impedance tomography. Physiol. Meas. 17, A1–A6 (1996)CrossRef
37.
go back to reference Malmivuo, J., Plonsey, R.: Bioelectromagnetism: principles and applications of bioelectric and biomagnetic fields, Chap. 26, Sect. 26.2.1. Oxford University Press, New York (1995) Malmivuo, J., Plonsey, R.: Bioelectromagnetism: principles and applications of bioelectric and biomagnetic fields, Chap. 26, Sect. 26.2.1. Oxford University Press, New York (1995)
38.
go back to reference Bera, T.K., Nagaraju, J.: Studying the 2D resistivity reconstruction of stainless steel electrode phantoms using different current patterns of electrical impedance tomography (EIT). In: Biomedical Engineering, Narosa Publishing House, Proceeding of the International Conference on Biomedical Engineering 2011 (ICBME-2011), Manipal, pp. 163–169 (2011) Bera, T.K., Nagaraju, J.: Studying the 2D resistivity reconstruction of stainless steel electrode phantoms using different current patterns of electrical impedance tomography (EIT). In: Biomedical Engineering, Narosa Publishing House, Proceeding of the International Conference on Biomedical Engineering 2011 (ICBME-2011), Manipal, pp. 163–169 (2011)
39.
go back to reference Polydorides, N., Lionheart, W.R.B.: A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the electrical impedance and diffuse optical reconstruction software project. Meas. Sci. Technol. 13, 1871–1883 (2002)CrossRef Polydorides, N., Lionheart, W.R.B.: A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the electrical impedance and diffuse optical reconstruction software project. Meas. Sci. Technol. 13, 1871–1883 (2002)CrossRef
40.
go back to reference Bera, T.K., Nagaraju, J.: A MATLAB based boundary data simulator for studying the resistivity reconstruction using neighbouring current pattern. J. Med. Eng. 15 (2013) (Article ID 193578) Bera, T.K., Nagaraju, J.: A MATLAB based boundary data simulator for studying the resistivity reconstruction using neighbouring current pattern. J. Med. Eng. 15 (2013) (Article ID 193578)
41.
go back to reference Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Image reconstruction in electrical impedance tomography (EIT) with projection error propagation-based regularization (PEPR): a practical phantom study. In: Lecture Notes in Computer Science, vol. 7135/2012, pp. 95–105. Springer, Berlin (2012) Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Image reconstruction in electrical impedance tomography (EIT) with projection error propagation-based regularization (PEPR): a practical phantom study. In: Lecture Notes in Computer Science, vol. 7135/2012, pp. 95–105. Springer, Berlin (2012)
42.
go back to reference Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Improving the image reconstruction in electrical impedance tomography (EIT) with block matrix-based multiple regularization (BMMR): a practical phantom study. In: IEEE World Congress on Information and Communication Technologies, India, pp. 1346–1351 (2011) Bera, T.K., Biswas, S.K., Rajan, K., Nagaraju, J.: Improving the image reconstruction in electrical impedance tomography (EIT) with block matrix-based multiple regularization (BMMR): a practical phantom study. In: IEEE World Congress on Information and Communication Technologies, India, pp. 1346–1351 (2011)
43.
go back to reference Bera, T.K., Nagaraju, J.: Studying the elemental resistivity profile of electrical impedance tomography (EIT) images to assess the reconstructed image quality. In: 5th International Conference on Information Processing (ICIP 2011). Communications in Computer and Information Science, vol. 157 (CCIS-157), India, pp. 621–630 (2011) Bera, T.K., Nagaraju, J.: Studying the elemental resistivity profile of electrical impedance tomography (EIT) images to assess the reconstructed image quality. In: 5th International Conference on Information Processing (ICIP 2011). Communications in Computer and Information Science, vol. 157 (CCIS-157), India, pp. 621–630 (2011)
44.
go back to reference Bera, T.K., Nagaraju, J.: Gold electrode sensors for electrical impedance tomography (EIT) studies. In: IEEE Sensors Application Symposium, USA, pp. 24–28 (2011) Bera, T.K., Nagaraju, J.: Gold electrode sensors for electrical impedance tomography (EIT) studies. In: IEEE Sensors Application Symposium, USA, pp. 24–28 (2011)
45.
go back to reference Data Sheet, MAX038-high-frequency waveform generator, Maxim Integrated Prod., Inc. USA Data Sheet, MAX038-high-frequency waveform generator, Maxim Integrated Prod., Inc. USA
46.
go back to reference Data Sheet, AD811—120 MHz, High Speed, Low Noise Video Op Amp, Analog Devices, Inc Data Sheet, AD811—120 MHz, High Speed, Low Noise Video Op Amp, Analog Devices, Inc
47.
go back to reference Bell, A.: Operational Amplifiers: Applications, Design and Troubleshooting, 2nd Edn, pp. 272–276. Prentice-Hall, Englewood Cliffs, Chap. 11, 9 Jan 1990 Bell, A.: Operational Amplifiers: Applications, Design and Troubleshooting, 2nd Edn, pp. 272–276. Prentice-Hall, Englewood Cliffs, Chap. 11, 9 Jan 1990
48.
go back to reference Wang, P., Guo, B., Li, N.: Multi-index optimization design for electrical resistance tomography sensor. Measurement 46(8), 2845–2853 (2013)CrossRefMathSciNet Wang, P., Guo, B., Li, N.: Multi-index optimization design for electrical resistance tomography sensor. Measurement 46(8), 2845–2853 (2013)CrossRefMathSciNet
49.
go back to reference Li, Y., Soleimani, M.: Imaging conductive materials with high frequency electrical capacitance tomography. Measurement 46, 3355–3361 (2013) Li, Y., Soleimani, M.: Imaging conductive materials with high frequency electrical capacitance tomography. Measurement 46, 3355–3361 (2013)
50.
go back to reference Gao, H., Xu, C., Fu, F., Wang, S.: Effects of particle charging on electrical capacitance tomography system. Measurement 45(3), 375–383 (2012)CrossRef Gao, H., Xu, C., Fu, F., Wang, S.: Effects of particle charging on electrical capacitance tomography system. Measurement 45(3), 375–383 (2012)CrossRef
51.
go back to reference Fan, Z., Gao, R.X., Wang, J.: Virtual instrument for online electrical capacitance tomography, practical applications and solutions using LabVIEW, Edited by Folea Silviu, ISBN 978-953-307-650-8, Published: Aug 1 2011 under CC BY-NC-SA 3.0 license Fan, Z., Gao, R.X., Wang, J.: Virtual instrument for online electrical capacitance tomography, practical applications and solutions using LabVIEW, Edited by Folea Silviu, ISBN 978-953-307-650-8, Published: Aug 1 2011 under CC BY-NC-SA 3.0 license
52.
go back to reference Dickin, F., Wang, M.: Electrical resistance tomography for process applications. Meas. Sci. Technol. 7, 247–260 (1996)CrossRef Dickin, F., Wang, M.: Electrical resistance tomography for process applications. Meas. Sci. Technol. 7, 247–260 (1996)CrossRef
53.
go back to reference Daffy, W., Ramlrez, A.: Electrical resistance tomography during in situ trichloroethylene remediation at the Savannah River Site. J. Appl. Geophys. 33, 239–249 (1995)CrossRef Daffy, W., Ramlrez, A.: Electrical resistance tomography during in situ trichloroethylene remediation at the Savannah River Site. J. Appl. Geophys. 33, 239–249 (1995)CrossRef
54.
go back to reference Beauvais, A., Ritz, M., Parisot, J.-C., Dukhan, M., Bantsimba, C.: Analysis of poorly stratified lateritic terrains overlying a granitic bedrock in West Africa, using 2-D electrical resistivity tomography. Earth Planet. Sci. Lett. 173, 413–424 (1999)CrossRef Beauvais, A., Ritz, M., Parisot, J.-C., Dukhan, M., Bantsimba, C.: Analysis of poorly stratified lateritic terrains overlying a granitic bedrock in West Africa, using 2-D electrical resistivity tomography. Earth Planet. Sci. Lett. 173, 413–424 (1999)CrossRef
55.
go back to reference Kemna, A., Vanderborght, J., Kulessa, B., Vereecken, H.: Imaging and characterisation of subsurface solute transport using electrical resistivity tomography (ERT) and equivalent transport models. J. Hydrol. 267, 125–146 (2002)CrossRef Kemna, A., Vanderborght, J., Kulessa, B., Vereecken, H.: Imaging and characterisation of subsurface solute transport using electrical resistivity tomography (ERT) and equivalent transport models. J. Hydrol. 267, 125–146 (2002)CrossRef
56.
go back to reference Beauvaisa, A., Ritz, M., Parisot, J.-C., Bantsimba, C., Dukhan, M.: Combined ERT and GPR methods for investigating two-stepped lateritic weathering systems. Geoderma 119, 121–132 (2004)CrossRef Beauvaisa, A., Ritz, M., Parisot, J.-C., Bantsimba, C., Dukhan, M.: Combined ERT and GPR methods for investigating two-stepped lateritic weathering systems. Geoderma 119, 121–132 (2004)CrossRef
57.
go back to reference Data Sheet, DIP Switches, EDG/EDS type, Excel Cell Electronic Co. Ltd., No. 20, 25th Rd., Taichung Industrial Park, Taichung, Taiwan Data Sheet, DIP Switches, EDG/EDS type, Excel Cell Electronic Co. Ltd., No. 20, 25th Rd., Taichung Industrial Park, Taichung, Taiwan
58.
go back to reference Cheng, K.S., Simske, S.J., Isaacson, D., Newell, J.C., Gisser, D.G.: Errors due to measuring voltage on current-carrying electrodes in electric current computed tomography. IEEE Trans. Biomed. Eng. 37(60), 60–65 (1990)CrossRef Cheng, K.S., Simske, S.J., Isaacson, D., Newell, J.C., Gisser, D.G.: Errors due to measuring voltage on current-carrying electrodes in electric current computed tomography. IEEE Trans. Biomed. Eng. 37(60), 60–65 (1990)CrossRef
59.
go back to reference Bera, T.K., Nagaraju, J.: A FEM-based forward solver for studying the forward problem of electrical impedance tomography (EIT) with a practical biological phantom. In: Proceedings of IEEE International Advance Computing Conference’ 2009 (IEEE IACC 2009), 6–7th Mar 2009, Patiala, Punjab, India, pp. 1375–1381 Bera, T.K., Nagaraju, J.: A FEM-based forward solver for studying the forward problem of electrical impedance tomography (EIT) with a practical biological phantom. In: Proceedings of IEEE International Advance Computing Conference’ 2009 (IEEE IACC 2009), 6–7th Mar 2009, Patiala, Punjab, India, pp. 1375–1381
Metadata
Title
A Low Cost Electrical Impedance Tomography (EIT) Instrumentation for Impedance Imaging of Practical Phantoms: A Laboratory Study
Authors
Tushar Kanti Bera
J. Nagaraju
Copyright Year
2014
Publisher
Springer India
DOI
https://doi.org/10.1007/978-81-322-1768-8_60

Premium Partner