Skip to main content
Top
Published in: Medical & Biological Engineering & Computing 8/2016

01-08-2016 | Original Article

A phantom axon setup for validating models of action potential recordings

Authors: Olivier Rossel, Fabien Soulier, Serge Bernard, David Guiraud, Guy Cathébras

Published in: Medical & Biological Engineering & Computing | Issue 8/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Electrode designs and strategies for electroneurogram recordings are often tested first by computer simulations and then by animal models, but they are rarely implanted for long-term evaluation in humans. The models show that the amplitude of the potential at the surface of an axon is higher in front of the nodes of Ranvier than at the internodes; however, this has not been investigated through in vivo measurements. An original experimental method is presented to emulate a single fiber action potential in an infinite conductive volume, allowing the potential of an axon to be recorded at both the nodes of Ranvier and the internodes, for a wide range of electrode-to-fiber radial distances. The paper particularly investigates the differences in the action potential amplitude along the longitudinal axis of an axon. At a short radial distance, the action potential amplitude measured in front of a node of Ranvier is two times larger than in the middle of two nodes. Moreover, farther from the phantom axon, the measured action potential amplitude is almost constant along the longitudinal axis. The results of this new method confirm the computer simulations, with a correlation of 97.6 %.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Andreasen LNS, Struijk JJ, Haugland MK (1997) An artificial nerve fiber for evaluation of nerve cuff electrodes. In: Proceedings of the 19th annual international conference of the IEEE engineering in medicine and biology society, 1997, vol 5, pp 1997–1999 Andreasen LNS, Struijk JJ, Haugland MK (1997) An artificial nerve fiber for evaluation of nerve cuff electrodes. In: Proceedings of the 19th annual international conference of the IEEE engineering in medicine and biology society, 1997, vol 5, pp 1997–1999
2.
go back to reference Andreasen LNS, Struijk JJ, Lawrence SM (2000) Measurement of the performance of nerve cuff electrodes for recording. Med Biol Eng Comput 38:447–453CrossRefPubMed Andreasen LNS, Struijk JJ, Lawrence SM (2000) Measurement of the performance of nerve cuff electrodes for recording. Med Biol Eng Comput 38:447–453CrossRefPubMed
3.
go back to reference Andreasen LNS, Struijk JJ (2002) Signal strength versus cuff length in nerve cuff electrode recordings. IEEE Trans Biomed Eng 49:1045–1050CrossRefPubMed Andreasen LNS, Struijk JJ (2002) Signal strength versus cuff length in nerve cuff electrode recordings. IEEE Trans Biomed Eng 49:1045–1050CrossRefPubMed
4.
go back to reference Brian W, Durand DM (2011) Selective recovery of fascicular activity in peripheral nerves. J Neural Eng 8:056005CrossRef Brian W, Durand DM (2011) Selective recovery of fascicular activity in peripheral nerves. J Neural Eng 8:056005CrossRef
5.
go back to reference Cavallaro E, Micera S, Dario P, Jensen W, Sinkjaer T (2003) On the intersubject generalization ability in extracting kinematic information from afferent nervous signals. IEEE Trans Biomed Eng 50:1063–1073CrossRefPubMed Cavallaro E, Micera S, Dario P, Jensen W, Sinkjaer T (2003) On the intersubject generalization ability in extracting kinematic information from afferent nervous signals. IEEE Trans Biomed Eng 50:1063–1073CrossRefPubMed
6.
go back to reference Clark JW (2009) The origin of biopotentials. In: Webster JG (ed) Medical instrumentation, application and design ch. 4. Wileyfourth ed. Wiley, New York, pp 126–188 Clark JW (2009) The origin of biopotentials. In: Webster JG (ed) Medical instrumentation, application and design ch. 4. Wileyfourth ed. Wiley, New York, pp 126–188
8.
go back to reference De Luca CJ, Hostage EC (2010) Relationship between firing rate and recruitment threshold of motoneurons in voluntary isometric contractions. J Neurophysiol 104:1034–1046CrossRefPubMedPubMedCentral De Luca CJ, Hostage EC (2010) Relationship between firing rate and recruitment threshold of motoneurons in voluntary isometric contractions. J Neurophysiol 104:1034–1046CrossRefPubMedPubMedCentral
9.
go back to reference Dhillon GS, Horch KW (2005) Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 13:468–472CrossRefPubMed Dhillon GS, Horch KW (2005) Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 13:468–472CrossRefPubMed
10.
go back to reference Djilas M, Azevedo Coste C, Guiraud D, Yoshida K (2009) Interpretation of muscle spindle afferent nerve response to passive muscle stretch recorded with thin-film longitudinal intrafascicular electrodes. IEEE TNSRE 17:445–453 Djilas M, Azevedo Coste C, Guiraud D, Yoshida K (2009) Interpretation of muscle spindle afferent nerve response to passive muscle stretch recorded with thin-film longitudinal intrafascicular electrodes. IEEE TNSRE 17:445–453
11.
go back to reference Djilas M, Azevedo-Coste C, Guiraud D, Yoshida K (2010) Spike sorting of muscle spindle afferent nerve activity recorded with thin-film intrafascicular electrodes. Intell Neurosci 2010:9:1–9:10 Djilas M, Azevedo-Coste C, Guiraud D, Yoshida K (2010) Spike sorting of muscle spindle afferent nerve activity recorded with thin-film intrafascicular electrodes. Intell Neurosci 2010:9:1–9:10
13.
go back to reference Huigen E, Peper A, Grimbergen CA (2002) Investigation into the origin of the noise of surface electrodes. Med Biol Eng Comput 40:332–338CrossRefPubMed Huigen E, Peper A, Grimbergen CA (2002) Investigation into the origin of the noise of surface electrodes. Med Biol Eng Comput 40:332–338CrossRefPubMed
14.
go back to reference Liu X, Demosthenous A, Donaldson N (2008) Platinum electrode noise in the ENG spectrum. Med Biol Eng Comput 46:997–1003CrossRefPubMed Liu X, Demosthenous A, Donaldson N (2008) Platinum electrode noise in the ENG spectrum. Med Biol Eng Comput 46:997–1003CrossRefPubMed
15.
go back to reference Loeb GE, Marks WB, Beatty PG (1977) Electrode arrays intended for chronic, multiple single-unit recording from captured nerve fibres. Med Biol Eng Comput 15:195–201CrossRefPubMed Loeb GE, Marks WB, Beatty PG (1977) Electrode arrays intended for chronic, multiple single-unit recording from captured nerve fibres. Med Biol Eng Comput 15:195–201CrossRefPubMed
16.
go back to reference McIntyre CC, Richardson AG, Grill WM (2002) Modeling the excitability of mammalian nerve fibers: influence of afterpotentials on the recovery cycle. J Neurophysiol 87:995–1006PubMed McIntyre CC, Richardson AG, Grill WM (2002) Modeling the excitability of mammalian nerve fibers: influence of afterpotentials on the recovery cycle. J Neurophysiol 87:995–1006PubMed
17.
go back to reference Meier JH, Rutten WLC, Boom HBK (1998) Extracellular potentials from active myelinated fibers inside insulated and noninsulated peripheral nerve. IEEE Trans Biomed Eng 45:1146–1153CrossRefPubMed Meier JH, Rutten WLC, Boom HBK (1998) Extracellular potentials from active myelinated fibers inside insulated and noninsulated peripheral nerve. IEEE Trans Biomed Eng 45:1146–1153CrossRefPubMed
18.
go back to reference Navarro X, Krueger TB, Lago N, Micera S, Stieglitz Thomas, Dario Paolo (2005) A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J Peripher Nerv Syst 10:229–258CrossRefPubMed Navarro X, Krueger TB, Lago N, Micera S, Stieglitz Thomas, Dario Paolo (2005) A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J Peripher Nerv Syst 10:229–258CrossRefPubMed
19.
go back to reference Nielsen TN, Sevcencu C, Struijk JJ (2014) Comparison of mono-, bi-, and tripolar configurations for stimulation and recording with an interfascicular interface. IEEE Trans Neural Syst Rehabil Eng 22:88–95CrossRefPubMed Nielsen TN, Sevcencu C, Struijk JJ (2014) Comparison of mono-, bi-, and tripolar configurations for stimulation and recording with an interfascicular interface. IEEE Trans Neural Syst Rehabil Eng 22:88–95CrossRefPubMed
20.
go back to reference Popovic DB, Stein RB, Jovanovic KL, Dai R, Kostov A, Armstrong WW (1993) Sensory nerve recording for closed-loop control to restore motor functions. IEEE Trans Biomed Eng 40:1024–1031CrossRefPubMed Popovic DB, Stein RB, Jovanovic KL, Dai R, Kostov A, Armstrong WW (1993) Sensory nerve recording for closed-loop control to restore motor functions. IEEE Trans Biomed Eng 40:1024–1031CrossRefPubMed
21.
go back to reference Qiao S, Odoemene O, Yoshida K (2012) Determination of electrode to nerve fiber distance and nerve conduction velocity through spectral analysis of the extracellular action potentials recorded from earthworm giant fibers. Med Biol Eng Comput 50:867–875CrossRefPubMed Qiao S, Odoemene O, Yoshida K (2012) Determination of electrode to nerve fiber distance and nerve conduction velocity through spectral analysis of the extracellular action potentials recorded from earthworm giant fibers. Med Biol Eng Comput 50:867–875CrossRefPubMed
22.
go back to reference Qiao S, Yoshida K (2013) Influence of unit distance and conduction velocity on the spectra of extracellular action potentials recorded with intrafascicular electrodes. Med Eng Phys 35:116–124CrossRefPubMed Qiao S, Yoshida K (2013) Influence of unit distance and conduction velocity on the spectra of extracellular action potentials recorded with intrafascicular electrodes. Med Eng Phys 35:116–124CrossRefPubMed
23.
go back to reference Rolston JD, Gross RE, Potter SM (2009) A low-cost multielectrode system for data acquisition enabling real-time closed-loop processing with rapid recovery from stimulation artifacts. Front Neuroeng 2(12):1–17 Rolston JD, Gross RE, Potter SM (2009) A low-cost multielectrode system for data acquisition enabling real-time closed-loop processing with rapid recovery from stimulation artifacts. Front Neuroeng 2(12):1–17
24.
go back to reference Rossel O, Soulier F, Bernard S, Cathebras G (2011) Sensitivity of a frequency-selective electrode based on spatial spectral properties of the extracellular AP of myelinated nerve fibers. In: Annual international conference of the IEEE engineering in medicine and biology society (EMBC 2011) pp 5843–5846 Rossel O, Soulier F, Bernard S, Cathebras G (2011) Sensitivity of a frequency-selective electrode based on spatial spectral properties of the extracellular AP of myelinated nerve fibers. In: Annual international conference of the IEEE engineering in medicine and biology society (EMBC 2011) pp 5843–5846
25.
go back to reference Rossel O, Soulier F, Cathebras G (2009) New electrode layout for internal selectivity of nerves. In: Annual international conference of the IEEE engineering in medicine and biology society, 2009 (EMBC 2009), pp 3798–3801 Rossel O, Soulier F, Cathebras G (2009) New electrode layout for internal selectivity of nerves. In: Annual international conference of the IEEE engineering in medicine and biology society, 2009 (EMBC 2009), pp 3798–3801
26.
go back to reference Rossel O, Soulier F, Coulombe J, Bernard S, Cathebras G (2011) Fascicle-selective multi-contact cuff electrode. In: Annual international conference of the IEEE engineering in medicine and biology society (EMBC 2011) pp 2989–2992 Rossel O, Soulier F, Coulombe J, Bernard S, Cathebras G (2011) Fascicle-selective multi-contact cuff electrode. In: Annual international conference of the IEEE engineering in medicine and biology society (EMBC 2011) pp 2989–2992
27.
go back to reference Rossini PM, Micera S, Benvenuto A et al (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121:777–783CrossRefPubMed Rossini PM, Micera S, Benvenuto A et al (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121:777–783CrossRefPubMed
28.
go back to reference Rutten WLC, Frieswijk TA, Smit JPA, Rozijn TH, Meier JH (1995) 3D neuro-electronic interface devices for neuromuscular control: design studies and realisation steps. Biosens Bioelectron 10:141–153CrossRefPubMed Rutten WLC, Frieswijk TA, Smit JPA, Rozijn TH, Meier JH (1995) 3D neuro-electronic interface devices for neuromuscular control: design studies and realisation steps. Biosens Bioelectron 10:141–153CrossRefPubMed
29.
go back to reference Schuettler M, Donaldson N, Seetohul V, Taylor J (2013) Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff. J Neural Eng 10:036016CrossRefPubMed Schuettler M, Donaldson N, Seetohul V, Taylor J (2013) Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff. J Neural Eng 10:036016CrossRefPubMed
30.
go back to reference Strange KD, Hoffer JA (1999) Restoration of use of paralyzed limb muscles using sensory nerve signals for state control of FES-assisted walking. IEEE Trans Rehabil Eng 7:289–300CrossRefPubMed Strange KD, Hoffer JA (1999) Restoration of use of paralyzed limb muscles using sensory nerve signals for state control of FES-assisted walking. IEEE Trans Rehabil Eng 7:289–300CrossRefPubMed
31.
go back to reference Struijk JJ, Haugland MK, Thomsen M (1996) Fascicle selective recording with a nerve cuff electrode. In: Proceedings of the 18th annual international conference of the IEEE engineering in medicine and biology society, 1996. Bridging disciplines for biomedicine, vol 1, pp 361–362 Struijk JJ, Haugland MK, Thomsen M (1996) Fascicle selective recording with a nerve cuff electrode. In: Proceedings of the 18th annual international conference of the IEEE engineering in medicine and biology society, 1996. Bridging disciplines for biomedicine, vol 1, pp 361–362
32.
go back to reference Struijk JJ (1997) On the spectrum of nerve cuff electrode recordings. In: Proceedings of the 19th annual international conference of the IEEE engineering in medicine and biology society, 1997, vol 5, pp 2006–2007 Struijk JJ (1997) On the spectrum of nerve cuff electrode recordings. In: Proceedings of the 19th annual international conference of the IEEE engineering in medicine and biology society, 1997, vol 5, pp 2006–2007
33.
34.
go back to reference Taylor J, Donaldson N, Winter J (2004) Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording. Med Biol Eng Comput 42:634–643CrossRefPubMed Taylor J, Donaldson N, Winter J (2004) Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording. Med Biol Eng Comput 42:634–643CrossRefPubMed
35.
go back to reference Taylor J, Schuettler M, Clarke C, Donaldson N (2012) The theory of velocity selective neural recording: a study based on simulation. Med Biol Eng Comput 50:309–318CrossRefPubMed Taylor J, Schuettler M, Clarke C, Donaldson N (2012) The theory of velocity selective neural recording: a study based on simulation. Med Biol Eng Comput 50:309–318CrossRefPubMed
36.
go back to reference Wodlinger B, Durand DM (2009) Localization and recovery of peripheral neural sources with beamforming algorithms. IEEE Trans Neural Syst Rehabil Eng 17:461–468CrossRefPubMedPubMedCentral Wodlinger B, Durand DM (2009) Localization and recovery of peripheral neural sources with beamforming algorithms. IEEE Trans Neural Syst Rehabil Eng 17:461–468CrossRefPubMedPubMedCentral
37.
go back to reference Yang Z, Zhao Q, Keefer E, Liu W (2009) Noise characterization, modeling, and reduction for in vivo neural recording. In: Bengio Y, Schuurmans D, Lafferty J, Williams CKI, Culotta A (eds) Advances in neural information processing systems, vol 22. MIT Press, Cambridge, pp 2160–2168 Yang Z, Zhao Q, Keefer E, Liu W (2009) Noise characterization, modeling, and reduction for in vivo neural recording. In: Bengio Y, Schuurmans D, Lafferty J, Williams CKI, Culotta A (eds) Advances in neural information processing systems, vol 22. MIT Press, Cambridge, pp 2160–2168
38.
go back to reference Yoo PB, Durand DM (2005) Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. IEEE Trans Biomed Eng 52:1461–1469CrossRefPubMed Yoo PB, Durand DM (2005) Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. IEEE Trans Biomed Eng 52:1461–1469CrossRefPubMed
39.
go back to reference Yoshida K, Horch KW (1996) Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation. IEEE Trans Biomed Eng 43:167–176CrossRefPubMed Yoshida K, Horch KW (1996) Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation. IEEE Trans Biomed Eng 43:167–176CrossRefPubMed
40.
go back to reference Zariffa J, Nagai MK, Daskalakis ZJ, Popovic MR (2009) Influence of the number and location of recording contacts on the selectivity of a nerve cuff electrode. IEEE Trans Neural Syst Rehabil Eng 17:420–427CrossRefPubMed Zariffa J, Nagai MK, Daskalakis ZJ, Popovic MR (2009) Influence of the number and location of recording contacts on the selectivity of a nerve cuff electrode. IEEE Trans Neural Syst Rehabil Eng 17:420–427CrossRefPubMed
41.
go back to reference Zariffa J, Nagai MK, Schuettler M, Stieglitz T, Daskalakis ZJ, Popovic MR (2011) Use of an experimentally derived leadfield in the peripheral nerve pathway discrimination problem. IEEE Trans Neural Syst Rehabil Eng 19:147–156CrossRefPubMed Zariffa J, Nagai MK, Schuettler M, Stieglitz T, Daskalakis ZJ, Popovic MR (2011) Use of an experimentally derived leadfield in the peripheral nerve pathway discrimination problem. IEEE Trans Neural Syst Rehabil Eng 19:147–156CrossRefPubMed
Metadata
Title
A phantom axon setup for validating models of action potential recordings
Authors
Olivier Rossel
Fabien Soulier
Serge Bernard
David Guiraud
Guy Cathébras
Publication date
01-08-2016
Publisher
Springer Berlin Heidelberg
Published in
Medical & Biological Engineering & Computing / Issue 8/2016
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-016-1463-3

Other articles of this Issue 8/2016

Medical & Biological Engineering & Computing 8/2016 Go to the issue

Premium Partner