Skip to main content
Top
Published in: Journal of Failure Analysis and Prevention 2/2008

01-04-2008 | Case History---Peer-Reviewed

Analysis and Redesign Report for Overhung Fan

Author: Mitchell Stansloski

Published in: Journal of Failure Analysis and Prevention | Issue 2/2008

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

At Sunoco Chemicals in LaPorte, Texas, multiple resonant conditions exist on the skid and bearing support structure of an overhung fan. These are excited by the fan shaft speed and harmonics, as well as the fan blade passing frequency. The skid has modes in two planes on both long sections of channel, as well as modes on the two fan-side cross beams. The channel and angle supporting the motor also experience a resonant condition. The bearing support has modes on all five sides of the box. Most significant of these, however, are the right-hand and left-hand sides when viewed from the sheave end of the fan shaft. In addition to experiencing multiple resonances, there was virtually no damping present in the system. Calculations made from several different impact test ring-downs revealed damping factors less than 1%. The result of a small damping coefficient is that amplification at resonance is extremely large. At 1% damping, amplification factors can approach 100:1. By increasing damping to 10%, amplification can be reduced to 3:1. From data collected, we calculated that the existing isolation system does no better than 30% isolation. Proper isolation is 90–97%. As a result of these problems, we recommended the following: (i) Fill the interior of the skid structure with epoxy grout. This will eliminate the skid natural frequencies in the operating range, and raise its damping factor to nearly 10%. (ii) Add a “torsion box” type stiffening system to the bearing support box. Also, add a piece of angle iron to the front and back edges of the box in order to secure it to the skid. These changes will raise its lowest natural frequency from 100 to 450 Hz, well above the operating frequencies, including blade passing frequency. (iii) Modify the exterior of the skid to accommodate four isolation springs, specified to bring the vibration isolation to 97%. This will also reduce the dynamic load passed from the fan to the building steel from nearly 20,000 pounds to as low as 173 pounds. This reduction is dynamic load will more than make up for the additional 1,400 pounds static load due to the grout addition, steel modifications, and springs.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Metadata
Title
Analysis and Redesign Report for Overhung Fan
Author
Mitchell Stansloski
Publication date
01-04-2008
Publisher
Springer US
Published in
Journal of Failure Analysis and Prevention / Issue 2/2008
Print ISSN: 1547-7029
Electronic ISSN: 1864-1245
DOI
https://doi.org/10.1007/s11668-008-9127-8

Other articles of this Issue 2/2008

Journal of Failure Analysis and Prevention 2/2008 Go to the issue

Calendar

Events

Calender

Training

Premium Partners