Skip to main content
Top
Published in: Measurement Techniques 3/2016

14-07-2016

Analysis of Factors Affecting the Accuracy of Three-Dimensional Reconstruction of the Surface of Objects with Submicrometer Relief Obtained by Scanning Electron Microscope Stereo Images

Authors: A. Yu. Kuzin, A. L. Vasil’ev, V. B. Mityukhlyaev, A. A. Mikhutkin, P. A. Todua, M. N. Filippov

Published in: Measurement Techniques | Issue 3/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

We present analysis results of factors influencing the systematic error in 3-D reconstruction of surface reliefs based on stereo images obtained using the scanning electron microscope S-4800. The typical size for the surface relief elements is less than 1 μm. The main sources of the error are found. It is shown that for typical samples the main factor influencing the systematic error of 3-D reconstruction is the parallax measurement error.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference J. Goldstein, D. Newbury, and D. Joy, Scanning Electron Microscopy and x-Ray Microanalysis, Kluwer Academic, Plenum Publishers, New York (2003), 3rd ed.CrossRef J. Goldstein, D. Newbury, and D. Joy, Scanning Electron Microscopy and x-Ray Microanalysis, Kluwer Academic, Plenum Publishers, New York (2003), 3rd ed.CrossRef
2.
go back to reference G. Piazzesi, “Photogrammetry with the scanning electron microscope,” J. Phys. E: Sci. Instrum., 6, No. 4, 392–396 (1973).ADSCrossRef G. Piazzesi, “Photogrammetry with the scanning electron microscope,” J. Phys. E: Sci. Instrum., 6, No. 4, 392–396 (1973).ADSCrossRef
3.
go back to reference F. Marinello, P. Bariani, E. Savio, et al., “Critical factors in SEM 3D stereo microscopy.” Meas. Sci. Technol., 19, No. 6, 065705-1–12 (2008).ADSCrossRef F. Marinello, P. Bariani, E. Savio, et al., “Critical factors in SEM 3D stereo microscopy.” Meas. Sci. Technol., 19, No. 6, 065705-1–12 (2008).ADSCrossRef
4.
go back to reference L. Carli, G. Genta, A. Cantatore, et al., “Uncertainty evaluation for three-dimensional scanning electron microscope reconstructions based on the stereo-pair technique,” Meas. Sci. Technol., 22, No. 3, 035103-1–11 (2011).ADSCrossRef L. Carli, G. Genta, A. Cantatore, et al., “Uncertainty evaluation for three-dimensional scanning electron microscope reconstructions based on the stereo-pair technique,” Meas. Sci. Technol., 22, No. 3, 035103-1–11 (2011).ADSCrossRef
5.
go back to reference P. Bariani, L. De Chiffre, H. N. Hansen, and A. Horsewell, “Investigation on the traceability of three-dimensional scacaning electron microscope measurements based on the stereo-pair technique,” Precis. Eng., 29, 219–228 (2005).CrossRef P. Bariani, L. De Chiffre, H. N. Hansen, and A. Horsewell, “Investigation on the traceability of three-dimensional scacaning electron microscope measurements based on the stereo-pair technique,” Precis. Eng., 29, 219–228 (2005).CrossRef
6.
go back to reference GOST P 8.736-2011, GSI. DirectRrepeated Measurements. Methods for Processing the Measurement Results. Main Provisions. GOST P 8.736-2011, GSI. DirectRrepeated Measurements. Methods for Processing the Measurement Results. Main Provisions.
7.
go back to reference GOST P 8.636-2007, GSI. Microscopes with Electronic Raster. Methods of Calibration. GOST P 8.636-2007, GSI. Microscopes with Electronic Raster. Methods of Calibration.
8.
go back to reference V. P. Gavrilenko, D. A. Karabanov, A. Yu. Kuzin, et al., “Three-dimensional reconstruction of surface relief structures on stereo images obtained in a scanning electron microscope,” Izmer. Tekhn., No. 3, 15–18 (2015). V. P. Gavrilenko, D. A. Karabanov, A. Yu. Kuzin, et al., “Three-dimensional reconstruction of surface relief structures on stereo images obtained in a scanning electron microscope,” Izmer. Tekhn., No. 3, 15–18 (2015).
Metadata
Title
Analysis of Factors Affecting the Accuracy of Three-Dimensional Reconstruction of the Surface of Objects with Submicrometer Relief Obtained by Scanning Electron Microscope Stereo Images
Authors
A. Yu. Kuzin
A. L. Vasil’ev
V. B. Mityukhlyaev
A. A. Mikhutkin
P. A. Todua
M. N. Filippov
Publication date
14-07-2016
Publisher
Springer US
Published in
Measurement Techniques / Issue 3/2016
Print ISSN: 0543-1972
Electronic ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-016-0948-7

Other articles of this Issue 3/2016

Measurement Techniques 3/2016 Go to the issue