Analysis of Transient Voltage Stability Under the Interaction Between HVDC Receiving End and New Energy Station

Authors : Zunmin Liu, Deping Ke, Jian Xu, Xin Sun, Xiaojiu Ma

Published in: The Proceedings of 2023 International Conference on Wireless Power Transfer (ICWPT2023)

Publisher: Springer Nature Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

When Short-circuit fault occurs at the receiving end of High Voltage Direct Current (HVDC), it is easy to cause voltage instability of the new energy station at HVDC receiving end. Therefore, the mechanism of the interaction between the new energy station and the HVDC receiving end and its influence on the voltage stability are analyzed. Firstly, the mathematical model of the new energy station is established by taking the photovoltaic (PV) station as an example, and its active power-voltage and reactive power-voltage characteristics are deduced. The active-voltage characteristics determine the upper limit of voltage recovery rate at the receiving end. The reactive power-voltage characteristics show that the reactive power characteristics of the new energy station are similar to that of the capacitor. Secondly, through the power flow equation of the HVDC receiving end, the influence of the active power-voltage characteristics on the voltage stability of the receiving end is analyzed. Finally, the deduced active power-voltage and reactive power-voltage characteristics of the new energy station are verified by simulation, and the output active power of the new energy station will affect the voltage recovery rate at HVDC receiving end, and thus affect the voltage stability.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Zhao, W., Huang, Z., Pan, Y., et al.: Static voltage stability analysis of receiving⁃end grid with DC infeed high penetration renewable energy. J. North China Electr. Power Univ. 49, 11–19 (2022). (in Chinese) Zhao, W., Huang, Z., Pan, Y., et al.: Static voltage stability analysis of receiving⁃end grid with DC infeed high penetration renewable energy. J. North China Electr. Power Univ. 49, 11–19 (2022). (in Chinese)
2.
go back to reference Wang, Y., Han, X., Sun, D., et al.: Analysis on voltage stability of receiving grid considering control strategy of DC transmission line. Autom. Electr. Power Syst. 40, 35–41 (2016). (in Chinese) Wang, Y., Han, X., Sun, D., et al.: Analysis on voltage stability of receiving grid considering control strategy of DC transmission line. Autom. Electr. Power Syst. 40, 35–41 (2016). (in Chinese)
13.
go back to reference Jin, Y., He, J., Li, G., et al.: Commutation failure of UHVDC system for wind farm integration (Part II): characteristics and mechanism analysis of transient reactive power and voltage of wind powers in sending terminal grid. In: Proceedings of the CSEE, vol. 42, pp. 4738–4749 (2022). https://doi.org/10.13334/j.0258-8013.pcsee.210044 (in Chinese) Jin, Y., He, J., Li, G., et al.: Commutation failure of UHVDC system for wind farm integration (Part II): characteristics and mechanism analysis of transient reactive power and voltage of wind powers in sending terminal grid. In: Proceedings of the CSEE, vol. 42, pp. 4738–4749 (2022). https://​doi.​org/​10.​13334/​j.​0258-8013.​pcsee.​210044 (in Chinese)
15.
go back to reference Xiong, X., Ouyang, J., Wen, A.: An analysis on impacts and characteristics of stator voltage of DFIG-based wind turbine generator under grid short circuit. Autom. Electr. Power Syst. 36, 143–149 (2012). (in Chinese) Xiong, X., Ouyang, J., Wen, A.: An analysis on impacts and characteristics of stator voltage of DFIG-based wind turbine generator under grid short circuit. Autom. Electr. Power Syst. 36, 143–149 (2012). (in Chinese)
17.
go back to reference Dahono, P.A., Bahar, Y.R., Sato, Y., Kataoka, T.: Damping of transient oscillations on the output LC filter of PWM inverters by using a virtual resistor. In: 4th IEEE International Conference on Power Electronics and Drive Systems. IEEE PEDS 2001 - Indonesia. Proceedings (Cat. No.01TH8594), vol. 1, pp. 403–407 (2001) Dahono, P.A., Bahar, Y.R., Sato, Y., Kataoka, T.: Damping of transient oscillations on the output LC filter of PWM inverters by using a virtual resistor. In: 4th IEEE International Conference on Power Electronics and Drive Systems. IEEE PEDS 2001 - Indonesia. Proceedings (Cat. No.01TH8594), vol. 1, pp. 403–407 (2001)
Metadata
Title
Analysis of Transient Voltage Stability Under the Interaction Between HVDC Receiving End and New Energy Station
Authors
Zunmin Liu
Deping Ke
Jian Xu
Xin Sun
Xiaojiu Ma
Copyright Year
2024
Publisher
Springer Nature Singapore
DOI
https://doi.org/10.1007/978-981-97-0877-2_13