Skip to main content
Top

2018 | OriginalPaper | Chapter

Comparative Analysis of Feed-Forward and Synchronous Reference Frame Control-Based Dynamic Voltage Restorer

Authors : A. Rini Ann Jerin, K. Palanisamy, S. Umashankar, Padmanaban Sanjeevikumar

Published in: Advances in Power Systems and Energy Management

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The protection of nonlinear and sensitive loads can be achieved economically through series compensation-based dynamic voltage restorer. The effective voltage compensation by dynamic voltage restorer depends on the controller used for voltage sag detection. In this paper, the sag detection of dynamic voltage restorer employing feed-forward control and synchronous reference frame control are compared. The efficiency of sag detection of these controls in dynamic voltage restorer for in-phase compensation of balanced sags with PWM-based injection of compensation voltage is analyzed. Comparisons on the performance of the controllers are shown clearly using Matlab/Simulink-based simulated results.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Sadigh, A.K., Smedley, K.M.: Review of voltage compensation methods in dynamic voltage restorer (DVR). In2012 IEEE Power and Energy Society General Meeting, pp. 1–8 (2012) Sadigh, A.K., Smedley, K.M.: Review of voltage compensation methods in dynamic voltage restorer (DVR). In2012 IEEE Power and Energy Society General Meeting, pp. 1–8 (2012)
2.
go back to reference Thirumoorthy, A.D., Chellamuthu, C.: Study on Power Quality Issue Of Grid Connected Wind Farm. Centre for Wind Energy Technology (CWET), March 2014, http://cwet.res.in/ Thirumoorthy, A.D., Chellamuthu, C.: Study on Power Quality Issue Of Grid Connected Wind Farm. Centre for Wind Energy Technology (CWET), March 2014, http://​cwet.​res.​in/​
3.
go back to reference Padiyar, K.R.: FACTS controllers in power transmission and distribution. New Age International (2007) Padiyar, K.R.: FACTS controllers in power transmission and distribution. New Age International (2007)
4.
go back to reference Jing, W., Aiqin, X., Yueyue, S.: A survey on control strategies of dynamic voltage restorer. In: 2008 13th International Conference on Harmonics and Quality of Power, pp. 1–5. IEEE (2008) Jing, W., Aiqin, X., Yueyue, S.: A survey on control strategies of dynamic voltage restorer. In: 2008 13th International Conference on Harmonics and Quality of Power, pp. 1–5. IEEE (2008)
5.
go back to reference Jayaprakash, P., Singh, B., Kothari, D.P., Chandra, A., Al-Haddad, K.: Control of reduced-rating dynamic voltage restorer with a battery energy storage system. IEEE Trans. Ind. Appl. 50(2), 1295–1303 (2014) Jayaprakash, P., Singh, B., Kothari, D.P., Chandra, A., Al-Haddad, K.: Control of reduced-rating dynamic voltage restorer with a battery energy storage system. IEEE Trans. Ind. Appl. 50(2), 1295–1303 (2014)
6.
go back to reference Prabaharan, N., Palanisamy, K.: Investigation of single phase reduced switch count asymmetric multilevel inverter using advanced pulse width modulation Technique. Int. J. Renew. Energy Res. 5(3), 879–890 (2015) Prabaharan, N., Palanisamy, K.: Investigation of single phase reduced switch count asymmetric multilevel inverter using advanced pulse width modulation Technique. Int. J. Renew. Energy Res. 5(3), 879–890 (2015)
7.
go back to reference Prabaharan, N., Palanisamy, K.: Comparative Analysis of Symmetric and Asymmetric Reduced Switch Multilevel Inverter Topology Using Unipolar Pulse Width Modulation Strategies. IET Power Electronics. doi:10.1049/iet-pel.2016.0283 Prabaharan, N., Palanisamy, K.: Comparative Analysis of Symmetric and Asymmetric Reduced Switch Multilevel Inverter Topology Using Unipolar Pulse Width Modulation Strategies. IET Power Electronics. doi:10.​1049/​iet-pel.​2016.​0283
8.
go back to reference Kanjiya, P., et al.: “SRF theory revisited” to control self-supported dynamic voltage restorer (DVR) for unbalanced and nonlinear loads. IEEE Trans. Ind. Appl. 49(5), 2330–2340 (2013)CrossRef Kanjiya, P., et al.: “SRF theory revisited” to control self-supported dynamic voltage restorer (DVR) for unbalanced and nonlinear loads. IEEE Trans. Ind. Appl. 49(5), 2330–2340 (2013)CrossRef
9.
go back to reference Li, Y.W., Vilathgamuwa, D.M., Blaabjerg, F., Loh, P.C.: A robust control scheme for medium-voltage-level DVR implementation. IEEE Trans. Industr. Electron. 54(4), 2249–2261 (2007)CrossRef Li, Y.W., Vilathgamuwa, D.M., Blaabjerg, F., Loh, P.C.: A robust control scheme for medium-voltage-level DVR implementation. IEEE Trans. Industr. Electron. 54(4), 2249–2261 (2007)CrossRef
10.
go back to reference Fitzer, C., Barnes, M., Green, P.: Voltage sag detection technique for a dynamic voltage restorer. In: Industry Applications Conference, 2002. 37th IAS Annual Meeting. Conference Record of the, vol. 2, pp. 917–924, (2002) Fitzer, C., Barnes, M., Green, P.: Voltage sag detection technique for a dynamic voltage restorer. In: Industry Applications Conference, 2002. 37th IAS Annual Meeting. Conference Record of the, vol. 2, pp. 917–924, (2002)
11.
go back to reference Kanjiya, P., Singh, B., Jayaprakash, P.: A robust control algorithm for self supported dynamic voltage restorer (DVR). In: India International Conference on Power Electronics 2010 (IICPE2010), pp. 1–8. IEEE (2011) Kanjiya, P., Singh, B., Jayaprakash, P.: A robust control algorithm for self supported dynamic voltage restorer (DVR). In: India International Conference on Power Electronics 2010 (IICPE2010), pp. 1–8. IEEE (2011)
Metadata
Title
Comparative Analysis of Feed-Forward and Synchronous Reference Frame Control-Based Dynamic Voltage Restorer
Authors
A. Rini Ann Jerin
K. Palanisamy
S. Umashankar
Padmanaban Sanjeevikumar
Copyright Year
2018
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-4394-9_41