Skip to main content
Top

2018 | OriginalPaper | Chapter

Comparison of the Periimplant Bone Stress Distribution on Three Fixed Partial Supported Prosthesis Designs Under Different Loading. A 3D Finite Element Analysis

Authors : Héctor deLlanos-Lanchares, Ángel Alvarez-Arenal, Javier Bobes Bascaran, Carlos González-Gutiérrez, Ana Suarez Sanchez, Francisco Blanco Álvarez

Published in: International Joint Conference SOCO’17-CISIS’17-ICEUTE’17 León, Spain, September 6–8, 2017, Proceeding

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Background: Despite high success and survival rates of implant supported prosthesis therapy, biomechanical complications such as periimplant bone resorption continue to exist due to occlusal overloading.
Purpose: To analyze and compare the influence of bone density, direction and distribution of the occlusal load and the design of three-unit implant supported prostheses.
Materials and methods: Three dimensional finite element analysis study was developed to evaluate the influence on the periimplant bone stress distribution of three different designs of a 3-unit bridge supported by two implants (intermediate pontic, tilted implant, cantilever pontic), two different bone qualities (D3 and D4), and different loading directions (axial and non axial) and distributions (uniform and non uniform).
Results: Bridge configuration with intermediate pontic and parallel implants presents the lowest periimplant stress, whereas the highest stress was found on the tilted implant bridge. Bone D3 is biomechanically more favourable than D4. Non axial and uniform loading conditions produce more periimplant stress.
Conclusions: Distal cantilever and 45˚ convergent distal tilted implant are the second and third treatment options on a posterior three unit rehabilitation. Lightening occlusal contacts on the pontic and avoiding non axial loading, reduce periimplant bone stress. Bone D4 increases periimplant bone strain.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Pjetursson, B.E., Thoma, D., Jung, R., Zwahlen, M., Zembic, A.: A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FPDs) after a mean observation period of at least 5 years. Clin. Oral Implants Res. 23, 22–38 (2012)CrossRef Pjetursson, B.E., Thoma, D., Jung, R., Zwahlen, M., Zembic, A.: A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FPDs) after a mean observation period of at least 5 years. Clin. Oral Implants Res. 23, 22–38 (2012)CrossRef
2.
go back to reference Sahin, S., Çehreli, M., Yalçin, E.: The influence of functional forces on the biomechanics of implant-supported prostheses-a review. J. Dentistry 30, 271–282 (2002)CrossRef Sahin, S., Çehreli, M., Yalçin, E.: The influence of functional forces on the biomechanics of implant-supported prostheses-a review. J. Dentistry 30, 271–282 (2002)CrossRef
3.
go back to reference Eliasson, A., Eriksson, T., Johansson, A., Wennerberg, A.: Fixed partial prostheses supported by 2 or 3 implants: a retrospective study up to 18 years. Int. J. Oral Maxillofac. Implants 21, 567–574 (2006) Eliasson, A., Eriksson, T., Johansson, A., Wennerberg, A.: Fixed partial prostheses supported by 2 or 3 implants: a retrospective study up to 18 years. Int. J. Oral Maxillofac. Implants 21, 567–574 (2006)
4.
go back to reference Hälg, G.A., Schmid, J., Hämmerle, C.H.F.: Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilever. Clin. Oral Impl. Res. 19, 983–990 (2008)CrossRef Hälg, G.A., Schmid, J., Hämmerle, C.H.F.: Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilever. Clin. Oral Impl. Res. 19, 983–990 (2008)CrossRef
5.
go back to reference Zampelis, A., Rangert, B., Heijl, L.: Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis. J. Prosthet. Dent. 97, 35–43 (2007)CrossRef Zampelis, A., Rangert, B., Heijl, L.: Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis. J. Prosthet. Dent. 97, 35–43 (2007)CrossRef
6.
go back to reference Frost, H.M.: Bone’s Mechanostat: a update. Anat. Rec. 275, 1081–1101 (2003)CrossRef Frost, H.M.: Bone’s Mechanostat: a update. Anat. Rec. 275, 1081–1101 (2003)CrossRef
7.
go back to reference Zurdo, J., Romão, C., Wennström, J.L.: Survival and complication rates of implant-supported fixed partial dentures with cantilevers: a systematic reviwe. Clin. Oral Implants Res. 20, 59–66 (2009)CrossRef Zurdo, J., Romão, C., Wennström, J.L.: Survival and complication rates of implant-supported fixed partial dentures with cantilevers: a systematic reviwe. Clin. Oral Implants Res. 20, 59–66 (2009)CrossRef
8.
go back to reference Sevimay, M., Turhan, F., Kiliçarslan, A., Eskitascioglu, G.: Three-dimensional finite element análisis of the effect of different bone quality on stress distribution in a implant-supported crown. J. Prosthet. Dent. 93, 227–234 (2005)CrossRef Sevimay, M., Turhan, F., Kiliçarslan, A., Eskitascioglu, G.: Three-dimensional finite element análisis of the effect of different bone quality on stress distribution in a implant-supported crown. J. Prosthet. Dent. 93, 227–234 (2005)CrossRef
9.
go back to reference Woelfel, J.B., Scheid, R.: Dental Anatomy: Its relevance to Dentistry, 5º ed., pp, 93–128. Williams & Wilkins. Baltimore (1997) Woelfel, J.B., Scheid, R.: Dental Anatomy: Its relevance to Dentistry, 5º ed., pp, 93–128. Williams & Wilkins. Baltimore (1997)
10.
go back to reference Geng, J., Tan, K.B., Liu, G.: Application of finite element analysis in implant dentistry: a review of the literature. J. Prosthet. Dent. 85, 585–598 (2001)CrossRef Geng, J., Tan, K.B., Liu, G.: Application of finite element analysis in implant dentistry: a review of the literature. J. Prosthet. Dent. 85, 585–598 (2001)CrossRef
11.
go back to reference Li, T., Kong, L., Wang, Y., Hu, K., Song, L., Liu, B., Li, D., Shao, J., Ding, Y.: Selection of optimal dental implant diameter and length type IV bone: a three-dimensional finite element analysis. Int. J. Oral Maxillofac. Implants 38, 1077–1083 (2009)CrossRef Li, T., Kong, L., Wang, Y., Hu, K., Song, L., Liu, B., Li, D., Shao, J., Ding, Y.: Selection of optimal dental implant diameter and length type IV bone: a three-dimensional finite element analysis. Int. J. Oral Maxillofac. Implants 38, 1077–1083 (2009)CrossRef
12.
go back to reference Kim, Y., Oh, T.J., Misch, C.E., Wang, H.L.: Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin. Oral Implants Res. 16, 26–35 (2005)CrossRef Kim, Y., Oh, T.J., Misch, C.E., Wang, H.L.: Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin. Oral Implants Res. 16, 26–35 (2005)CrossRef
13.
go back to reference Bidez, M.W., Misch, C.E.: Biomecánica clínica en implantología. In: Misch, C.E. (ed.) Implantología Contemporánea, 3a edn. Elsevier, Barcelona (2009) Bidez, M.W., Misch, C.E.: Biomecánica clínica en implantología. In: Misch, C.E. (ed.) Implantología Contemporánea, 3a edn. Elsevier, Barcelona (2009)
14.
go back to reference Alvarez Menendez, L., de Cos Juez, F.J., Sanchez Lasheras, F.: Artificial neural networks applied to cancer detection in a breast screening programme. Math. Comput. Model. 52(7–8), 983–991 (2010)MathSciNetCrossRefMATH Alvarez Menendez, L., de Cos Juez, F.J., Sanchez Lasheras, F.: Artificial neural networks applied to cancer detection in a breast screening programme. Math. Comput. Model. 52(7–8), 983–991 (2010)MathSciNetCrossRefMATH
15.
go back to reference Bevilacqua, M., Tealdo, T., Menini, M., Pera, F., Mossolov, A., Drago, C., Pera, P.: The influence of cantiléver length and implant inclination on stress distribution in maxillary implant-supported fixed dentures. J. Prosthet. Dent. 105, 5–13 (2010)CrossRef Bevilacqua, M., Tealdo, T., Menini, M., Pera, F., Mossolov, A., Drago, C., Pera, P.: The influence of cantiléver length and implant inclination on stress distribution in maxillary implant-supported fixed dentures. J. Prosthet. Dent. 105, 5–13 (2010)CrossRef
17.
go back to reference Yokoyama, S., Wakabayashi, N., Shiota, M., Ohyama, T.: The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures. J. Prosthet. Dent. 91, 234–240 (2004)CrossRef Yokoyama, S., Wakabayashi, N., Shiota, M., Ohyama, T.: The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures. J. Prosthet. Dent. 91, 234–240 (2004)CrossRef
18.
go back to reference Osborn, J., Guzman, D., de Cos Juez, F.J., Basden, A.G., Morris, T.J., Gendron, E., Butterley, T., Myers, R.M., Guesalaga, A., Sanchez Lasheras, F., Gomez Victoria, M., Sánchez Rodríguez, M.L., Gratadour, D., Roussetc, G.: Open-loop tomography with artificial neural networks on CANARY: on-sky results. Mon. Not. R. Astron. Soc. 441(3), 2508–2514 (2014)CrossRef Osborn, J., Guzman, D., de Cos Juez, F.J., Basden, A.G., Morris, T.J., Gendron, E., Butterley, T., Myers, R.M., Guesalaga, A., Sanchez Lasheras, F., Gomez Victoria, M., Sánchez Rodríguez, M.L., Gratadour, D., Roussetc, G.: Open-loop tomography with artificial neural networks on CANARY: on-sky results. Mon. Not. R. Astron. Soc. 441(3), 2508–2514 (2014)CrossRef
19.
go back to reference Vilán Vilán, J.A., Alonso Fernández, J.R., García Nieto, P.J., Sánchez Lasheras, F., de Cos Juez, F.J., Díaz Muñiz, C.: Support vector machines and multilayer perceptron networks used to evaluate the cyanotoxins presence from experimental cyanobacteria concentrations in the trasona reservoir (Northern Spain). Water Resour. Manag. 27(9), 3457–3476 (2013)CrossRef Vilán Vilán, J.A., Alonso Fernández, J.R., García Nieto, P.J., Sánchez Lasheras, F., de Cos Juez, F.J., Díaz Muñiz, C.: Support vector machines and multilayer perceptron networks used to evaluate the cyanotoxins presence from experimental cyanobacteria concentrations in the trasona reservoir (Northern Spain). Water Resour. Manag. 27(9), 3457–3476 (2013)CrossRef
20.
go back to reference Watanabe, M., Hattori, Y., Satoh, C.: Biological and biomechanical perspectives of normal dental occlusion. Int. Congress Series 1284, 21–27 (2005)CrossRef Watanabe, M., Hattori, Y., Satoh, C.: Biological and biomechanical perspectives of normal dental occlusion. Int. Congress Series 1284, 21–27 (2005)CrossRef
21.
go back to reference Baggi, L., Pastore, S., Di Girolamo, M., Vairo, G.: Implant-bone load transfer mechanism in complete-arch prostheses support by four implants: a three-dimensional finite element approach. J. Prosthet. Dent. 109, 9–21 (2013)CrossRef Baggi, L., Pastore, S., Di Girolamo, M., Vairo, G.: Implant-bone load transfer mechanism in complete-arch prostheses support by four implants: a three-dimensional finite element approach. J. Prosthet. Dent. 109, 9–21 (2013)CrossRef
22.
go back to reference Osborn, J., De Cos Juez, F.J., Guzman, D., Butterley, T., Myers, R., Guesalaga, A., Laine, J.: Using artificial neural networks for open-loop tomography. Opt. Express 20(3), 2420–2434 (2012)CrossRef Osborn, J., De Cos Juez, F.J., Guzman, D., Butterley, T., Myers, R., Guesalaga, A., Laine, J.: Using artificial neural networks for open-loop tomography. Opt. Express 20(3), 2420–2434 (2012)CrossRef
23.
go back to reference Cardelli, P., Montani, M., Gallio, M., Biancolini, M., Brutti, C., Barlattani, A.: Angulated abutments and perimplants stress: FEM analysis. Oral Implantol. 2, 3–10 (2009) Cardelli, P., Montani, M., Gallio, M., Biancolini, M., Brutti, C., Barlattani, A.: Angulated abutments and perimplants stress: FEM analysis. Oral Implantol. 2, 3–10 (2009)
24.
go back to reference De Cos Juez, F.J., Sánchez Lasheras, F., García Nieto, P.J., Suárez Suárez, M.A.: A new data mining methodology applied to the modelling of the influence of diet and lifestyle on the value of bone mineral density in post-menopausal women. Int. J. Comput. Math. 86, 1878–1887 (2009). https://doi.org/10.1080/00207160902783557. La Manga del Mar MenorCrossRefMATH De Cos Juez, F.J., Sánchez Lasheras, F., García Nieto, P.J., Suárez Suárez, M.A.: A new data mining methodology applied to the modelling of the influence of diet and lifestyle on the value of bone mineral density in post-menopausal women. Int. J. Comput. Math. 86, 1878–1887 (2009). https://​doi.​org/​10.​1080/​0020716090278355​7. La Manga del Mar MenorCrossRefMATH
25.
go back to reference Lin, C.L., Lin, Y.H., Chang, S.H.: Multi-factorial analysis of variables influencing the bone loss of an implant placed in the maxilla: prediction using FEA and SED bone remodeling algorithm. J. Biomech. 43, 644–651 (2010)CrossRef Lin, C.L., Lin, Y.H., Chang, S.H.: Multi-factorial analysis of variables influencing the bone loss of an implant placed in the maxilla: prediction using FEA and SED bone remodeling algorithm. J. Biomech. 43, 644–651 (2010)CrossRef
27.
go back to reference Villar, J.R., Vergara, P., Menéndez, M., de la Cal, E., González, V.M., Sedano, J.: Generalized models for the classification of abnormal movements in daily life and its applicability to epilepsy convulsion recognition. Int. J. Neural Syst. 26(6), 1650037 (2016)CrossRef Villar, J.R., Vergara, P., Menéndez, M., de la Cal, E., González, V.M., Sedano, J.: Generalized models for the classification of abnormal movements in daily life and its applicability to epilepsy convulsion recognition. Int. J. Neural Syst. 26(6), 1650037 (2016)CrossRef
28.
go back to reference González, S., Sedano, J., Villar, J.R., Corchado, E., Herrero, Á., Baruque, B.: Features and models for human activity recognition. Neurocomputing 167, 52–60 (2015)CrossRef González, S., Sedano, J., Villar, J.R., Corchado, E., Herrero, Á., Baruque, B.: Features and models for human activity recognition. Neurocomputing 167, 52–60 (2015)CrossRef
29.
go back to reference Nagasawa, S., Hayano, K., Niino, T., Yamakura, K., et al.: Nonlinear stress analysis of titanium implants by finite element method. Dent. Mater. J. 27, 633–639 (2008)CrossRef Nagasawa, S., Hayano, K., Niino, T., Yamakura, K., et al.: Nonlinear stress analysis of titanium implants by finite element method. Dent. Mater. J. 27, 633–639 (2008)CrossRef
32.
go back to reference Lan, T.H., Pan, C.Y., Lee, H.E., Huang, H.L., Wang, C.H.: Bone stress analysis of various angulations of mesiodistal implants with splinted crowns in the posterior mandible: a three-dimensional finite element study. Int. J. Oral Maxillofac. Implants 25, 763–770 (2010) Lan, T.H., Pan, C.Y., Lee, H.E., Huang, H.L., Wang, C.H.: Bone stress analysis of various angulations of mesiodistal implants with splinted crowns in the posterior mandible: a three-dimensional finite element study. Int. J. Oral Maxillofac. Implants 25, 763–770 (2010)
33.
go back to reference Fishwick, P.A., Zeigler, B.P.: Qualitative physics: towards the automation of systems problem solving. J. Exp. Theor. Artif. Intell. 3(3), 219–246 (1991)CrossRef Fishwick, P.A., Zeigler, B.P.: Qualitative physics: towards the automation of systems problem solving. J. Exp. Theor. Artif. Intell. 3(3), 219–246 (1991)CrossRef
34.
go back to reference Li, H., Duan, W., Huang, H.-Z.: Neurocomputing method based on structural finite element analysis of discrete model. Neural Comput. Appl. 19(6), 875–882 (2010)CrossRef Li, H., Duan, W., Huang, H.-Z.: Neurocomputing method based on structural finite element analysis of discrete model. Neural Comput. Appl. 19(6), 875–882 (2010)CrossRef
35.
go back to reference Shalin, V.L., Bertram, D.A.: Functions of expertise in a medical intensive care unit. J. Exp. Theor. Artif. Intell. 8(3–4), 209–227 (1996)CrossRef Shalin, V.L., Bertram, D.A.: Functions of expertise in a medical intensive care unit. J. Exp. Theor. Artif. Intell. 8(3–4), 209–227 (1996)CrossRef
36.
go back to reference Yildirim, Ş., Eski, İ., Polat, Y.: Design of adaptive neural predictor for failure analysis on hip and knee joints of humans. Neural Comput. Appl. 23(1), 73–87 (2013)CrossRef Yildirim, Ş., Eski, İ., Polat, Y.: Design of adaptive neural predictor for failure analysis on hip and knee joints of humans. Neural Comput. Appl. 23(1), 73–87 (2013)CrossRef
Metadata
Title
Comparison of the Periimplant Bone Stress Distribution on Three Fixed Partial Supported Prosthesis Designs Under Different Loading. A 3D Finite Element Analysis
Authors
Héctor deLlanos-Lanchares
Ángel Alvarez-Arenal
Javier Bobes Bascaran
Carlos González-Gutiérrez
Ana Suarez Sanchez
Francisco Blanco Álvarez
Copyright Year
2018
DOI
https://doi.org/10.1007/978-3-319-67180-2_40

Premium Partner