With the advent of powerful computers and parallel processing including Grid technology, the use of Monte Carlo (MC) techniques for radiation transport simulation has become the most popular method for modeling radiological imaging systems and particularly X-ray computed tomography (CT). The stochastic nature of involved processes such as X-ray photons generation, interaction with matter and detection makes MC the ideal tool for accurate modeling. MC calculations can be used to assess the impact of different physical design parameters on overall scanner performance, clinical image quality and absorbed dose assessment in CT examinations, which can be difficult or even impossible to estimate by experimental measurements and theoretical analysis. Simulations can also be used to develop and assess correction methods and reconstruction algorithms aiming at improving image quality and quantitative procedures. This paper focuses mainly on recent developments and future trends in X-ray CT MC modeling tools and their areas of application. An overview of existing programs and their useful features will be given together with recent developments in the design of computational anthropomorphic models of the human anatomy. It should be noted that due to limited space, the references contained herein are for illustrative purposes and are not inclusive; no implication that those chosen are better than others not mentioned is intended.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
2.
go back to reference Boone JM (2006) Multidetector CT: opportunities, challenges, and concerns associated with scanners with 64 or more detector rows. Radiology 241:334–337CrossRef Boone JM (2006) Multidetector CT: opportunities, challenges, and concerns associated with scanners with 64 or more detector rows. Radiology 241:334–337CrossRef
4.
go back to reference Tofts PS, Gore JC (1980) Some sources of artefact in computed tomography. Phys Med Biol 25:117–127CrossRef Tofts PS, Gore JC (1980) Some sources of artefact in computed tomography. Phys Med Biol 25:117–127CrossRef
5.
go back to reference Colijn AP, Beekman FJ (2004) Accelerated simulation of cone beam X-ray scatter projections. IEEE Trans Med Imaging 23:584–590CrossRef Colijn AP, Beekman FJ (2004) Accelerated simulation of cone beam X-ray scatter projections. IEEE Trans Med Imaging 23:584–590CrossRef
6.
go back to reference DeMarco JJ, Cagnon CH, Cody DD, Stevens DM, McCollough CH, Zankl M et al (2007) Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose. Phys Med Biol 52:2583–2597CrossRef DeMarco JJ, Cagnon CH, Cody DD, Stevens DM, McCollough CH, Zankl M et al (2007) Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose. Phys Med Biol 52:2583–2597CrossRef
7.
go back to reference Lee SC, Kim HK, Chun IK, Cho MH, Lee SY (2003) A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys Med Biol 48:4173–4185CrossRef Lee SC, Kim HK, Chun IK, Cho MH, Lee SY (2003) A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys Med Biol 48:4173–4185CrossRef
8.
go back to reference Ning R, Tang X, Conover D (2004) X-ray scatter correction algorithm for cone beam CT imaging. Med Phys 31:1195–1202CrossRef Ning R, Tang X, Conover D (2004) X-ray scatter correction algorithm for cone beam CT imaging. Med Phys 31:1195–1202CrossRef
9.
go back to reference Siewerdsen JH, Jaffray DA (2000) Optimization of X-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography). Med Phys 27:1903–1914CrossRef Siewerdsen JH, Jaffray DA (2000) Optimization of X-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography). Med Phys 27:1903–1914CrossRef
10.
go back to reference Tu S-J, Shaw CC, Chen L (2006) Noise simulation in cone beam CT imaging with parallel computing. Phys Med Biol 51:1283–1297CrossRef Tu S-J, Shaw CC, Chen L (2006) Noise simulation in cone beam CT imaging with parallel computing. Phys Med Biol 51:1283–1297CrossRef
11.
go back to reference Colijn AP, Zbijewski W, Sasov A, Beekman FJ (2004) Experimental validation of a rapid Monte Carlo based micro-CT simulator. Phys Med Biol 49:4321–4333CrossRef Colijn AP, Zbijewski W, Sasov A, Beekman FJ (2004) Experimental validation of a rapid Monte Carlo based micro-CT simulator. Phys Med Biol 49:4321–4333CrossRef
12.
go back to reference Ay M, Zaidi H (2005) Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam X-ray CT. Phys Med Biol 50:4863–4885CrossRef Ay M, Zaidi H (2005) Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam X-ray CT. Phys Med Biol 50:4863–4885CrossRef
13.
go back to reference Kanamori H, Nakamori N, Inoue K, Takenaka E (1985) Effect of scattered X-ray on CT images. Phys Med Biol 30:239–249CrossRef Kanamori H, Nakamori N, Inoue K, Takenaka E (1985) Effect of scattered X-ray on CT images. Phys Med Biol 30:239–249CrossRef
14.
go back to reference Malusek A, Seger MM, Sandborg M, Alm Carlsson G (2005) Effect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function. Radiat Prot Dosimetry 114:337–340CrossRef Malusek A, Seger MM, Sandborg M, Alm Carlsson G (2005) Effect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function. Radiat Prot Dosimetry 114:337–340CrossRef
15.
go back to reference Caon M, Bibbo G, Pattison J (1997) A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models. Phys Med Biol 42:219–29CrossRef Caon M, Bibbo G, Pattison J (1997) A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models. Phys Med Biol 42:219–29CrossRef
16.
go back to reference Khodaverdi M, Chatziioannou AF, Weber S, Ziemons K, Halling H, Pietrzyk U (2005) Investigation of different micro-CT scanner configurations by GEANT4 simulations. IEEE Trans Nucl Sci 52:188–192CrossRef Khodaverdi M, Chatziioannou AF, Weber S, Ziemons K, Halling H, Pietrzyk U (2005) Investigation of different micro-CT scanner configurations by GEANT4 simulations. IEEE Trans Nucl Sci 52:188–192CrossRef
17.
go back to reference Andreo A (1991) Monte Carlo techniques in medical radiation physics. Phys Med Biol 36:861–920CrossRef Andreo A (1991) Monte Carlo techniques in medical radiation physics. Phys Med Biol 36:861–920CrossRef
18.
go back to reference Zaidi H (1999) Relevance of accurate Monte Carlo modeling in nuclear medical imaging. Med Phys 26:574–608CrossRef Zaidi H (1999) Relevance of accurate Monte Carlo modeling in nuclear medical imaging. Med Phys 26:574–608CrossRef
19.
go back to reference Rogers DWO (2006) Fifty years of Monte Carlo simulations for medical physics. Phys Med Biol 51:R287–R301CrossRef Rogers DWO (2006) Fifty years of Monte Carlo simulations for medical physics. Phys Med Biol 51:R287–R301CrossRef
20.
go back to reference De Man B, Nuyts J, Dupont P, Marchal G, Suetens P (1999) Metal streak artifacts in X-ray computed tomography: a simulation study. IEEE Trans Nucl Sci 46:691–696CrossRef De Man B, Nuyts J, Dupont P, Marchal G, Suetens P (1999) Metal streak artifacts in X-ray computed tomography: a simulation study. IEEE Trans Nucl Sci 46:691–696CrossRef
21.
go back to reference De Francesco D, Da Silva A. Multislice spiral CT simulator for dynamic cardiopulmonary studies. Medical imaging 2002: Physiology and function from multidimensional images, San Diego, 2002, 4683:305–316 De Francesco D, Da Silva A. Multislice spiral CT simulator for dynamic cardiopulmonary studies. Medical imaging 2002: Physiology and function from multidimensional images, San Diego, 2002, 4683:305–316
22.
go back to reference DeMarco JJ, Cagnon CH, Cody DD, Stevens DM, McCollough CH, O’Daniel J et al (2005) A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. Phys Med Biol 50:3989–4004CrossRef DeMarco JJ, Cagnon CH, Cody DD, Stevens DM, McCollough CH, O’Daniel J et al (2005) A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. Phys Med Biol 50:3989–4004CrossRef
23.
go back to reference Boone JM, Buonocore MH, Cooper VN. (2000) Monte Carlo validation in diagnostic radiological imaging. Med Phys 27:1294–1304CrossRef Boone JM, Buonocore MH, Cooper VN. (2000) Monte Carlo validation in diagnostic radiological imaging. Med Phys 27:1294–1304CrossRef
24.
go back to reference Giersch J, Weidemann A, Anton G. (2003) ROSI-an object-oriented and parallel-computing Monte Carlo simulation for X-ray imaging. Nucl Instr Meth A 509:151–156CrossRef Giersch J, Weidemann A, Anton G. (2003) ROSI-an object-oriented and parallel-computing Monte Carlo simulation for X-ray imaging. Nucl Instr Meth A 509:151–156CrossRef
25.
go back to reference Winslow M, Xu XG, Yazici B. (2005) Development of a simulator for radiographic image optimization. Comput Methods Programs Biomed 78:179–190CrossRef Winslow M, Xu XG, Yazici B. (2005) Development of a simulator for radiographic image optimization. Comput Methods Programs Biomed 78:179–190CrossRef
26.
go back to reference Ay M, Shahriari M, Sarkar S, Adib M, Zaidi H. (2004) Monte Carlo simulation of X-ray spectra in diagnostic radiology and mammography using MCNP4C. Phys Med Biol 49:4897–4917CrossRef Ay M, Shahriari M, Sarkar S, Adib M, Zaidi H. (2004) Monte Carlo simulation of X-ray spectra in diagnostic radiology and mammography using MCNP4C. Phys Med Biol 49:4897–4917CrossRef
27.
go back to reference Tanner RJ, Chartier J-L, Siebert BRL, Agosteo S, Grosswendt B, Gualdrini G et al (2004) Intercomparison on the usage of computational codes in radiation dosimetry. Radiat Prot Dosimetry 110:769–780CrossRef Tanner RJ, Chartier J-L, Siebert BRL, Agosteo S, Grosswendt B, Gualdrini G et al (2004) Intercomparison on the usage of computational codes in radiation dosimetry. Radiat Prot Dosimetry 110:769–780CrossRef
28.
go back to reference Wiest PW, Locken JA, Heintz PH, Mettler FA Jr (2002) CT scanning: a major source of radiation exposure. Semin Ultrasound CT MR 23:402–410CrossRef Wiest PW, Locken JA, Heintz PH, Mettler FA Jr (2002) CT scanning: a major source of radiation exposure. Semin Ultrasound CT MR 23:402–410CrossRef
29.
go back to reference Salvado M, Lopez M, Morant JJ, Calzado A. (2005) Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models. Radiat Prot Dosimetry 114:364–368CrossRef Salvado M, Lopez M, Morant JJ, Calzado A. (2005) Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models. Radiat Prot Dosimetry 114:364–368CrossRef
30.
go back to reference Staton RJ, Lee C, Lee C, Williams MD, Hintenlang DE, Arreola MM, et al (2006) Organ and effective doses in newborn patients during helical multislice computed tomography examination. Phys Med Biol 51:5151–5166CrossRef Staton RJ, Lee C, Lee C, Williams MD, Hintenlang DE, Arreola MM, et al (2006) Organ and effective doses in newborn patients during helical multislice computed tomography examination. Phys Med Biol 51:5151–5166CrossRef
31.
go back to reference Tzedakis A, Perisinakis K, Raissaki M, Damilakis J. (2006) The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study. Med Phys 33:2472–2478CrossRef Tzedakis A, Perisinakis K, Raissaki M, Damilakis J. (2006) The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study. Med Phys 33:2472–2478CrossRef
32.
go back to reference Theocharopoulos N, Damilakis J, Perisinakis K, Tzedakis A, Karantanas A, Gourtsoyiannis N (2006) Estimation of effective doses to adult and pediatric patients from multislice computed tomography: a method based on energy imparted. Med Phys 33:3846–3856CrossRef Theocharopoulos N, Damilakis J, Perisinakis K, Tzedakis A, Karantanas A, Gourtsoyiannis N (2006) Estimation of effective doses to adult and pediatric patients from multislice computed tomography: a method based on energy imparted. Med Phys 33:3846–3856CrossRef
33.
go back to reference Taschereau R, Chow PL, Chatziioannou AF (2006) Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom. Med Phys 33:216–224CrossRef Taschereau R, Chow PL, Chatziioannou AF (2006) Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom. Med Phys 33:216–224CrossRef
34.
go back to reference Mazonakis M, Tzedakis A, Damilakis J, Gourtsoyiannis N (2007) Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction? Eur Radiol 17:1352–1357CrossRef Mazonakis M, Tzedakis A, Damilakis J, Gourtsoyiannis N (2007) Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction? Eur Radiol 17:1352–1357CrossRef
35.
go back to reference LeHeron JC. CTDOSE (1993) A computer program to enable the calculation of organ dose, dose indices for CT examinations. Ministry of Health, National Radiation Laboratory, Christchurch LeHeron JC. CTDOSE (1993) A computer program to enable the calculation of organ dose, dose indices for CT examinations. Ministry of Health, National Radiation Laboratory, Christchurch
36.
go back to reference Jones DG, Shrimpton PC (1991) Survey of CT practice in the UK. Part 3: Normalised organ doses calculated using Monte Carlo techniques. NRPB-R250, Chilton Jones DG, Shrimpton PC (1991) Survey of CT practice in the UK. Part 3: Normalised organ doses calculated using Monte Carlo techniques. NRPB-R250, Chilton
38.
go back to reference Ay M, Shahriari M, Sarkar S, Sardari D, Zaidi H (2005) Assessment of different computational models for generation of X-ray spectra in diagnostic radiology and mammography. Med Phys 32:1660–1675CrossRef Ay M, Shahriari M, Sarkar S, Sardari D, Zaidi H (2005) Assessment of different computational models for generation of X-ray spectra in diagnostic radiology and mammography. Med Phys 32:1660–1675CrossRef
39.
go back to reference Chan HP, Doi K (1985) Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies. Med Phys 12:152–165CrossRef Chan HP, Doi K (1985) Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies. Med Phys 12:152–165CrossRef
40.
go back to reference Cheng CW, Taylor KW, Holloway AF (1995) The spectrum and angular distribution of X-rays scattered from a water phantom. Med Phys 22:1235–1245CrossRef Cheng CW, Taylor KW, Holloway AF (1995) The spectrum and angular distribution of X-rays scattered from a water phantom. Med Phys 22:1235–1245CrossRef
41.
go back to reference Endo M, Tsunoo T, Nakamori N, Yoshida K (2001) Effect of scatter radiation on image noise in cone beam CT. Med Phys 28:469–474CrossRef Endo M, Tsunoo T, Nakamori N, Yoshida K (2001) Effect of scatter radiation on image noise in cone beam CT. Med Phys 28:469–474CrossRef
42.
go back to reference Endo M, Mori S, Tsunoo T, Miyazaki H (2006) Magnitude and effects of X-ray scatter in a 256-slice CT scanner. Med Phys 33:3359–3368CrossRef Endo M, Mori S, Tsunoo T, Miyazaki H (2006) Magnitude and effects of X-ray scatter in a 256-slice CT scanner. Med Phys 33:3359–3368CrossRef
43.
go back to reference Zbijewski W, Beekman FJ (2006) Efficient Monte Carlo-based scatter artifact reduction in cone-beam micro-CT. IEEE Trans Med Imaging 25:817–827CrossRef Zbijewski W, Beekman FJ (2006) Efficient Monte Carlo-based scatter artifact reduction in cone-beam micro-CT. IEEE Trans Med Imaging 25:817–827CrossRef
44.
go back to reference Ay M, Zaidi H (2006) Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET. Eur J Nucl Med Mol Imaging 33:1301–1313CrossRef Ay M, Zaidi H (2006) Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET. Eur J Nucl Med Mol Imaging 33:1301–1313CrossRef
45.
go back to reference Schmidt B, Kalender WA (2003) Advanced method for calculating the scatter signal contribution in CT detectors by the Monte Carlo method. Z Med Phys 13:30–39 Schmidt B, Kalender WA (2003) Advanced method for calculating the scatter signal contribution in CT detectors by the Monte Carlo method. Z Med Phys 13:30–39
46.
go back to reference Kyriakou Y, Riedel T, Kalender WA (2006) Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT. Phys Med Biol 51:4567–4586CrossRef Kyriakou Y, Riedel T, Kalender WA (2006) Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT. Phys Med Biol 51:4567–4586CrossRef
47.
go back to reference Zaidi H, Xu XG (2007) Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in medical imaging. Annu Rev Biomed Eng 9: doi:10.1146/annurev.bioeng.9.060906.151934 Zaidi H, Xu XG (2007) Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in medical imaging. Annu Rev Biomed Eng 9: doi:10.1146/annurev.bioeng.9.060906.151934
48.
go back to reference Goertzen AL, Beekman FJ, Cherry SR (2002) Effect of phantom voxelization in CT simulations. Med Phys 29:492–498CrossRef Goertzen AL, Beekman FJ, Cherry SR (2002) Effect of phantom voxelization in CT simulations. Med Phys 29:492–498CrossRef
49.
go back to reference Snyder W, Ford MR, Warner G (1978) Estimates of specific absorbed fractions for photon sources uniformly distributed in various organs of a heterogeneous phantom. Pamphlet No. 5, revised. New York: Society of Nuclear Medicine Snyder W, Ford MR, Warner G (1978) Estimates of specific absorbed fractions for photon sources uniformly distributed in various organs of a heterogeneous phantom. Pamphlet No. 5, revised. New York: Society of Nuclear Medicine
50.
go back to reference Cristy M, Eckerman KF (1987) Specific absorbed fractions of energy at various ages from internal photon sources. I Methods, II one year old, III five year old, IV ten year old, V fifteen year old male and adult female, VI new-born and VII adult male. ORNL/TM 8381/V1-V7, Oak Ridge National Laboratory, Oak Ridge Cristy M, Eckerman KF (1987) Specific absorbed fractions of energy at various ages from internal photon sources. I Methods, II one year old, III five year old, IV ten year old, V fifteen year old male and adult female, VI new-born and VII adult male. ORNL/TM 8381/V1-V7, Oak Ridge National Laboratory, Oak Ridge
51.
go back to reference Shepp LA, Logan BF (1974) The Fourier reconstruction of a head phantom. IEEE Trans Nucl Sci 21:21–43CrossRef Shepp LA, Logan BF (1974) The Fourier reconstruction of a head phantom. IEEE Trans Nucl Sci 21:21–43CrossRef
53.
go back to reference Peter J, Gilland DR, Jaszczak RJ, Coleman RE. (1999) Four-dimensional superquadric-based cardiac phantom for Monte Carlo simulation of radiological imaging systems. IEEE Trans Nucl Sci 46:2211–2217CrossRef Peter J, Gilland DR, Jaszczak RJ, Coleman RE. (1999) Four-dimensional superquadric-based cardiac phantom for Monte Carlo simulation of radiological imaging systems. IEEE Trans Nucl Sci 46:2211–2217CrossRef
54.
go back to reference Segars WP (2001) Development, application of the new dynamic NURBS-based cardiac-torso (NCAT) phantom [Ph.D Thesis]. University of North Carolina, Chapel Hill Segars WP (2001) Development, application of the new dynamic NURBS-based cardiac-torso (NCAT) phantom [Ph.D Thesis]. University of North Carolina, Chapel Hill
55.
go back to reference Zhu J, Zhao S, Ye Y, Wang G (2005) Computed tomography simulation with superquadrics. Med Phys 32:3136–3143CrossRef Zhu J, Zhao S, Ye Y, Wang G (2005) Computed tomography simulation with superquadrics. Med Phys 32:3136–3143CrossRef
56.
go back to reference LaCroix K (1997) Evaluation of an attenuation compensation method with respect to defect detection in Tc-99m-sestamibi myocardial SPECT [Ph.D Thesis]. University of North Carolina, Chapel Hill LaCroix K (1997) Evaluation of an attenuation compensation method with respect to defect detection in Tc-99m-sestamibi myocardial SPECT [Ph.D Thesis]. University of North Carolina, Chapel Hill
57.
go back to reference Segars WP, Tsui BM, Frey EC, Johnson GA, Berr SS (2004) Development of a 4D digital mouse phantom for molecular imaging research. Mol Imaging Biol 6:149–159CrossRef Segars WP, Tsui BM, Frey EC, Johnson GA, Berr SS (2004) Development of a 4D digital mouse phantom for molecular imaging research. Mol Imaging Biol 6:149–159CrossRef
58.
go back to reference Zubal IG, Harrell CR, Smith EO, Rattner Z, Gindi G, Hoffer BP (1994) Computerized 3-dimensional segmented human anatomy. Med Phys 21:299–302CrossRef Zubal IG, Harrell CR, Smith EO, Rattner Z, Gindi G, Hoffer BP (1994) Computerized 3-dimensional segmented human anatomy. Med Phys 21:299–302CrossRef
59.
go back to reference Xu XG, Chao TC, Bozkurt A (2000) VIP-Man: an image-based whole-body adult male model constructed from color photographs of the Visible Human Project for multi-particle Monte Carlo calculations. Health Phys 78:476–486CrossRef Xu XG, Chao TC, Bozkurt A (2000) VIP-Man: an image-based whole-body adult male model constructed from color photographs of the Visible Human Project for multi-particle Monte Carlo calculations. Health Phys 78:476–486CrossRef
60.
go back to reference Chao T-c, Xu XG (2004) S-values calculated from a tomographic head/brain model for brain imaging. Phys Med Biol 49:4971–4984CrossRef Chao T-c, Xu XG (2004) S-values calculated from a tomographic head/brain model for brain imaging. Phys Med Biol 49:4971–4984CrossRef
61.
go back to reference Petoussi-Henss N, Zankl M, Fill U, Regulla D (2002) The GSF family of voxel phantoms. Phys Med Biol 47:89–106CrossRef Petoussi-Henss N, Zankl M, Fill U, Regulla D (2002) The GSF family of voxel phantoms. Phys Med Biol 47:89–106CrossRef
62.
go back to reference Park JS, Chung MS, Hwang SB, Lee YS, Har DH, Park HS (2005) Visible Korean human: improved serially sectioned images of the entire body. IEEE Trans Med Imaging 24:352–360CrossRef Park JS, Chung MS, Hwang SB, Lee YS, Har DH, Park HS (2005) Visible Korean human: improved serially sectioned images of the entire body. IEEE Trans Med Imaging 24:352–360CrossRef
63.
go back to reference Nipper JC, Williams JL, Bolch WE (2002) Creation of two tomographic voxel models of paediatric patients in the first year of life. Phys Med Biol 47:3143–3164CrossRef Nipper JC, Williams JL, Bolch WE (2002) Creation of two tomographic voxel models of paediatric patients in the first year of life. Phys Med Biol 47:3143–3164CrossRef
64.
go back to reference Shi CY, Xu XG (2004) Development of a 30-week-pregnant female tomographic model from computed tomography (CT) images for Monte Carlo organ dose calculations. Med Phys 31:2491–2497CrossRef Shi CY, Xu XG (2004) Development of a 30-week-pregnant female tomographic model from computed tomography (CT) images for Monte Carlo organ dose calculations. Med Phys 31:2491–2497CrossRef
65.
go back to reference Zaidi H, Labbé C, Morel C (1998) Implementation of an environment for Monte Carlo simulation of fully 3D positron tomography on a high-performance parallel platform. Parallel Comput 24:1523–1536CrossRef Zaidi H, Labbé C, Morel C (1998) Implementation of an environment for Monte Carlo simulation of fully 3D positron tomography on a high-performance parallel platform. Parallel Comput 24:1523–1536CrossRef
66.
go back to reference Maigne L, Hill D, Calvat P, Breton V, Reuillon R, Lazaro D et al (2004) Parallelization of Monte Carlo simulations and submission to a Grid environment. Parallel Proc Lett 14:177–196CrossRef Maigne L, Hill D, Calvat P, Breton V, Reuillon R, Lazaro D et al (2004) Parallelization of Monte Carlo simulations and submission to a Grid environment. Parallel Proc Lett 14:177–196CrossRef
67.
go back to reference El Naqa I, Kawrakow I, Fippel M, Siebers JV, Lindsay PE, Wickerhauser MV et al (2005) A comparison of Monte Carlo dose calculation denoising techniques. Phys Med Biol 50:909–922CrossRef El Naqa I, Kawrakow I, Fippel M, Siebers JV, Lindsay PE, Wickerhauser MV et al (2005) A comparison of Monte Carlo dose calculation denoising techniques. Phys Med Biol 50:909–922CrossRef
68.
go back to reference Hughes RE, An KN (1997) Monte Carlo simulation of a planar shoulder model. Med Biol Eng Comput 35:544–548CrossRef Hughes RE, An KN (1997) Monte Carlo simulation of a planar shoulder model. Med Biol Eng Comput 35:544–548CrossRef
Metadata
Title
Current status and new horizons in Monte Carlo simulation of X-ray CT scanners
Authors
Habib Zaidi
Mohammad Reza Ay
Publication date
01-09-2007
Publisher
Springer-Verlag
Published in
Medical & Biological Engineering & Computing / Issue 9/2007
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-007-0207-9

Other articles of this Issue 9/2007

Medical & Biological Engineering & Computing 9/2007 Go to the issue

Premium Partner