Skip to main content
Top

2020 | OriginalPaper | Chapter

Detection and Identification Technologies for CBRN Agents

Author : Olivier Mattmann

Published in: 21st Century Prometheus

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This chapter provides an overview of available technologies for the detection and identification of agents released (alone or in mixtures), at the scene of a major intentional, accidental or natural CBRNE incident. These technologies are crucial to ensure adequate risk assessment, optimal risk management, and proper counter-measures including medical treatment, personal protection and restored access to infrastructure. In addition, monitoring/screening of these agents (and their precursors/dual agents) is also essential during production, storage and transport.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Appendix
Available only for authorised users
Footnotes
1
Immediately dangerous to life or health air concentration values.
 
Literature
go back to reference Anderson, G. P, and C.A. Rowe-Taitt. 2000. Water quality monitoring using an automated portable fiber optic biosensor: RAPTOR. Photonic detection and intervention technologies for safe food. Proc. SPIE 2000, 4206, 418742. Anderson, G. P, and C.A. Rowe-Taitt. 2000. Water quality monitoring using an automated portable fiber optic biosensor: RAPTOR. Photonic detection and intervention technologies for safe food. Proc. SPIE 2000, 4206, 418742.
go back to reference Bergström, T. 2016. Protein identification and characterization through peptide mass spectrometry. Method development for improved ricin and botulinum neurotoxin analysis. Doctoral Thesis, Swedish University of Agricultural Sciences, Umeå. Bergström, T. 2016. Protein identification and characterization through peptide mass spectrometry. Method development for improved ricin and botulinum neurotoxin analysis. Doctoral Thesis, Swedish University of Agricultural Sciences, Umeå.
go back to reference Carey, J.R., K.S. Suslick, K.I. Hulkower, et al. 2011. Rapid identification of bacteria with a disposable colorimetric sensing array. Journal of the American Chemical Society 133: 7571–7576.CrossRef Carey, J.R., K.S. Suslick, K.I. Hulkower, et al. 2011. Rapid identification of bacteria with a disposable colorimetric sensing array. Journal of the American Chemical Society 133: 7571–7576.CrossRef
go back to reference Dembek, Z.F., ed. 2011. USAMRIID’s medical management of biological casualties handbook. 7th ed. Fort Detrick: U.S. Army Medical Research Institute of Infectious Diseases. Dembek, Z.F., ed. 2011. USAMRIID’s medical management of biological casualties handbook. 7th ed. Fort Detrick: U.S. Army Medical Research Institute of Infectious Diseases.
go back to reference Favrot, C. 2015. Polymerase chain reaction: Advantages and drawbacks. In 3. Congresso Latinoamericano de Dermatologia Veterinaria, 26–27. Argentina: Buenos Aires. Favrot, C. 2015. Polymerase chain reaction: Advantages and drawbacks. In 3. Congresso Latinoamericano de Dermatologia Veterinaria, 26–27. Argentina: Buenos Aires.
go back to reference Feltis, B.N., B.A. Sexton, F.L. Glenn, et al. 2008. A Hand-held surface plasmon resonance biosensor for the detection of ricin and other biological agents. Biosensors and Bioelectronics 23: 1131–1136.CrossRef Feltis, B.N., B.A. Sexton, F.L. Glenn, et al. 2008. A Hand-held surface plasmon resonance biosensor for the detection of ricin and other biological agents. Biosensors and Bioelectronics 23: 1131–1136.CrossRef
go back to reference Feng, S., R. Caire, B. Cortazar, et al. 2014. Immunochromatographic diagnotic test analysis using google glass. ACS Nano 8: 3069–3079.CrossRef Feng, S., R. Caire, B. Cortazar, et al. 2014. Immunochromatographic diagnotic test analysis using google glass. ACS Nano 8: 3069–3079.CrossRef
go back to reference Fornara, A., P. Johansson, K. Petersson, et al. 2008. Tailored magnetic nanoparticles for direct and sensitive detection of biomolecules in biological samples. Nano Letters 2008 (8): 3423–3428.CrossRef Fornara, A., P. Johansson, K. Petersson, et al. 2008. Tailored magnetic nanoparticles for direct and sensitive detection of biomolecules in biological samples. Nano Letters 2008 (8): 3423–3428.CrossRef
go back to reference Hao, R.Z., H.B. Song, G.M. Zuo, et al. 2011. Probe functionalized QCM biosensor based on gold nanoparticle amplification for bacillus anthracis detection. Biosensors and Bioelectronics (26): 3398–3404.CrossRef Hao, R.Z., H.B. Song, G.M. Zuo, et al. 2011. Probe functionalized QCM biosensor based on gold nanoparticle amplification for bacillus anthracis detection. Biosensors and Bioelectronics (26): 3398–3404.CrossRef
go back to reference Ho, Y.P., and P.M. Reddy. 2010. Identification of pathogens by mass spectrometry. Clinical Chemistry 56: 525–536.CrossRef Ho, Y.P., and P.M. Reddy. 2010. Identification of pathogens by mass spectrometry. Clinical Chemistry 56: 525–536.CrossRef
go back to reference Jamshaid, T., E.T.T. Neto, M.M. Eissa, et al. 2016. Magnetic particles: From preparation to lab-on-a-chip, biosensors, microsystems and microfluidics applications. Trends in Analytical Chemistry 79: 344–362.CrossRef Jamshaid, T., E.T.T. Neto, M.M. Eissa, et al. 2016. Magnetic particles: From preparation to lab-on-a-chip, biosensors, microsystems and microfluidics applications. Trends in Analytical Chemistry 79: 344–362.CrossRef
go back to reference LCGC. n.d. Quadrupole mass analyzers: An introduction. LCGC Europe 25(11). LCGC. n.d. Quadrupole mass analyzers: An introduction. LCGC Europe 25(11).
go back to reference Li, D., Y. Feng, L. Zhou, et al. 2011. Label-Free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157: H7. Analytica Chimica Acta 687: 89–96.CrossRef Li, D., Y. Feng, L. Zhou, et al. 2011. Label-Free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157: H7. Analytica Chimica Acta 687: 89–96.CrossRef
go back to reference Lonsdale, C.L., B. Taba, N. Queralto, et al. 2013. The use of colorimetric sensor arrays to discriminate between pathogenic bacteria. PLoS One 2013 (8): e62726.CrossRef Lonsdale, C.L., B. Taba, N. Queralto, et al. 2013. The use of colorimetric sensor arrays to discriminate between pathogenic bacteria. PLoS One 2013 (8): e62726.CrossRef
go back to reference MacDonald, J., et al. 2003. Alternatives for landmine detection. RAND. MacDonald, J., et al. 2003. Alternatives for landmine detection. RAND.
go back to reference Mariani, S., and M. Minunni. 2014. Surface plasmon resonance applications in clinical analysis. Analytical and Bioanalytical Chemistry 406: 2303–2323.CrossRef Mariani, S., and M. Minunni. 2014. Surface plasmon resonance applications in clinical analysis. Analytical and Bioanalytical Chemistry 406: 2303–2323.CrossRef
go back to reference Maziejuk, M., W. Lisowski, M. Szyposzynska, T. Sikora, and A. Zalewska. 2015. Differential ion mobility spectrometry in application to the analysis of gases and vapors. Solid State Phenomena 223.CrossRef Maziejuk, M., W. Lisowski, M. Szyposzynska, T. Sikora, and A. Zalewska. 2015. Differential ion mobility spectrometry in application to the analysis of gases and vapors. Solid State Phenomena 223.CrossRef
go back to reference Mellon, F.A. 2003. Mass spectrometry – Principles and instrumentation. In Encyclopedia of food sciences and nutrition, 2nd ed. Elsevier. Mellon, F.A. 2003. Mass spectrometry – Principles and instrumentation. In Encyclopedia of food sciences and nutrition, 2nd ed. Elsevier.
go back to reference Miles, S. 1997. Rapid purification of small molecule libraries by ion exchange chromatography. Tetrahedron Letters. 38:3357–3358. Via Elsevier Science Direct. Miles, S. 1997. Rapid purification of small molecule libraries by ion exchange chromatography. Tetrahedron Letters. 38:3357–3358. Via Elsevier Science Direct.
go back to reference Ong, T.-H., T. Mendum, G. Geurtsen, et al. 2017. Use of mass spectrometric vapor analysis to improve canine explosive detection efficiency. Analytical Chemistry 89 (12): 6482–6490.CrossRef Ong, T.-H., T. Mendum, G. Geurtsen, et al. 2017. Use of mass spectrometric vapor analysis to improve canine explosive detection efficiency. Analytical Chemistry 89 (12): 6482–6490.CrossRef
go back to reference Priest, J.R. 2017. A primer to clinical genome sequencing. Current Opinion in Pediatrics (29): 513–519.CrossRef Priest, J.R. 2017. A primer to clinical genome sequencing. Current Opinion in Pediatrics (29): 513–519.CrossRef
go back to reference Rebmann, A., M.H. Sorg, and E. David. 2000. Cadaver dog handbook. Boca Raton, London, New York, Washington D.C.: CRC Press LLC. Rebmann, A., M.H. Sorg, and E. David. 2000. Cadaver dog handbook. Boca Raton, London, New York, Washington D.C.: CRC Press LLC.
go back to reference Sanchez-Rodas, D., W.T. Corns, B. Chen, and P.B. Stockwell. 2010. Atomic fluorescence spectrometry: A suitable detection technique in speciation studies for arsenic, selenium, antimony and mercury. Journal of Analytical Atomic Spectrometry 25: 933–946.CrossRef Sanchez-Rodas, D., W.T. Corns, B. Chen, and P.B. Stockwell. 2010. Atomic fluorescence spectrometry: A suitable detection technique in speciation studies for arsenic, selenium, antimony and mercury. Journal of Analytical Atomic Spectrometry 25: 933–946.CrossRef
go back to reference SAVER. 2005. Guide for the selection of chemical agent and toxic industrial material detection equipment for emergency first responders, Guide 100-04, Volume I and II: Summary; pp. 1–5. SAVER. 2005. Guide for the selection of chemical agent and toxic industrial material detection equipment for emergency first responders, Guide 100-04, Volume I and II: Summary; pp. 1–5.
go back to reference Schelkanova, I., A. Pandya, A. Muhaseen, G. Saiko, and A. Douplik. 2015. Chapter 13 – Early optical diagnosis of pressure ulcers. In Biophotonics for medical applications, vol. 2015, 347–375. Woodhead Publication Series Biomaterials Elsevier. Schelkanova, I., A. Pandya, A. Muhaseen, G. Saiko, and A. Douplik. 2015. Chapter 13 – Early optical diagnosis of pressure ulcers. In Biophotonics for medical applications, vol. 2015, 347–375. Woodhead Publication Series Biomaterials Elsevier.
go back to reference Seo, Y., J.-e Kim, Y. Jeong, et al. 2016. Engineered nanoconstructs for the multiplexed and sensitive detection of high-risk pathogens. Nanoscale 8: 1944–1951.CrossRef Seo, Y., J.-e Kim, Y. Jeong, et al. 2016. Engineered nanoconstructs for the multiplexed and sensitive detection of high-risk pathogens. Nanoscale 8: 1944–1951.CrossRef
go back to reference Sferopoulos, R. 2008. A review of chemical warfare agent (CWA) detector technologies and commercial-off-the-shelf items. Human Protection and Performance Division, Defense Science and Technology Organization, Australian Government. DSTO-GD-0570. Sferopoulos, R. 2008. A review of chemical warfare agent (CWA) detector technologies and commercial-off-the-shelf items. Human Protection and Performance Division, Defense Science and Technology Organization, Australian Government. DSTO-GD-0570.
go back to reference Sun, Y., and K.Y. Ong. 2005. Detection technologies for chemical warfare agents and Toxic Vapors. 1st ed, 272. Boca Raton: CRC Press. Sun, Y., and K.Y. Ong. 2005. Detection technologies for chemical warfare agents and Toxic Vapors. 1st ed, 272. Boca Raton: CRC Press.
go back to reference Taitt, C.R., L.C. Shriver-Lake, M.M. Ngundi, and F.S. Ligler. 2008. Array biosensor for toxin detection: Continued advances. Sensors 8: 8361–8377.CrossRef Taitt, C.R., L.C. Shriver-Lake, M.M. Ngundi, and F.S. Ligler. 2008. Array biosensor for toxin detection: Continued advances. Sensors 8: 8361–8377.CrossRef
go back to reference Terelii, M., and A. Tüzüni. 2014. New molecular methods for detection of bioterrorism agents. Türk Bilimsel Derlemeler Dergisi 7 (1): 46–48. Terelii, M., and A. Tüzüni. 2014. New molecular methods for detection of bioterrorism agents. Türk Bilimsel Derlemeler Dergisi 7 (1): 46–48.
go back to reference Thakur, S.N. 2007. Chapter 2 – Atomic emission spectroscopy. In Laser-induced breakdown spectroscopy, 23–48. Elsevier. Thakur, S.N. 2007. Chapter 2 – Atomic emission spectroscopy. In Laser-induced breakdown spectroscopy, 23–48. Elsevier.
go back to reference Vekey, K. 2001. Mass spectrometry and mass-selective detection in chromatography. Journal of Chromatography A 921: 227–236.CrossRef Vekey, K. 2001. Mass spectrometry and mass-selective detection in chromatography. Journal of Chromatography A 921: 227–236.CrossRef
go back to reference Vincent, A.T., N. Derome, B. Boyle, A.I. Culley, and S.J. Charette. 2017. Next-generation sequencing (NGS) in the microbiological world: How to make the most of your money. Journal of Microbiological Methods 138: 60–71.CrossRef Vincent, A.T., N. Derome, B. Boyle, A.I. Culley, and S.J. Charette. 2017. Next-generation sequencing (NGS) in the microbiological world: How to make the most of your money. Journal of Microbiological Methods 138: 60–71.CrossRef
go back to reference Visser, M., R. Bester, J.T. Burger, and H.J. Maree. 2016. Next-generation sequencing for virus detection: Covering all the bases. Virology Journal 13: 85.CrossRef Visser, M., R. Bester, J.T. Burger, and H.J. Maree. 2016. Next-generation sequencing for virus detection: Covering all the bases. Virology Journal 13: 85.CrossRef
go back to reference Voborova, O., M. Bentahir, A.-S. Piette, and J.-L. Gala. 2015. CBRN: Detection and identification innovations. Crisis Response Journal 2015: 36–38. Voborova, O., M. Bentahir, A.-S. Piette, and J.-L. Gala. 2015. CBRN: Detection and identification innovations. Crisis Response Journal 2015: 36–38.
go back to reference Walper, S.A., G.L. Aragonés, K.E. Sapsford, et al. 2018. Detecting biothreat agents: From current diagnostics to developing sensor technologies. ACS Sensing 2018 (3): 1894–2024.CrossRef Walper, S.A., G.L. Aragonés, K.E. Sapsford, et al. 2018. Detecting biothreat agents: From current diagnostics to developing sensor technologies. ACS Sensing 2018 (3): 1894–2024.CrossRef
go back to reference Warwick, B., and B. Dunn. 2011. Chapter 2 – Mass spectrometry in systems biology: An introduction. In Methods in enzymology, vol. 500. Elsevier. Warwick, B., and B. Dunn. 2011. Chapter 2 – Mass spectrometry in systems biology: An introduction. In Methods in enzymology, vol. 500. Elsevier.
go back to reference Wunderlich, B. 2001. Thermal analysis. In Encyclopedia of materials: Science and technology, 2nd ed. Elsevier. Wunderlich, B. 2001. Thermal analysis. In Encyclopedia of materials: Science and technology, 2nd ed. Elsevier.
go back to reference Zasada, A.A., K. Forminska, K. Zacharczuk, D. Jacob, and R. Grunow. 2015. Comparison of eleven commercially available rapid tests for detection of bacillus anthracis, francisella tularensis and yersinia pestis. Letters in Applied Microbiology 60: 409–413.CrossRef Zasada, A.A., K. Forminska, K. Zacharczuk, D. Jacob, and R. Grunow. 2015. Comparison of eleven commercially available rapid tests for detection of bacillus anthracis, francisella tularensis and yersinia pestis. Letters in Applied Microbiology 60: 409–413.CrossRef
go back to reference Zubarev, R.A., and A. Makarov. 2013. Orbitrap mass spectrometry. Analytical Chemistry 85 (11): 5288–5296.CrossRef Zubarev, R.A., and A. Makarov. 2013. Orbitrap mass spectrometry. Analytical Chemistry 85 (11): 5288–5296.CrossRef
Metadata
Title
Detection and Identification Technologies for CBRN Agents
Author
Olivier Mattmann
Copyright Year
2020
DOI
https://doi.org/10.1007/978-3-030-28285-1_11

Premium Partner