Abstract

Glaucoma is one of the major abnormalities in the eye which leads to permanent vision loss over time if left untreated. Prolonged high level of intraocular pressure (IOP) causes optic nerve damage leading to glaucoma. Glaucoma can be detected by analyzing the characteristics of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL). The quantitative analysis of the ocular details obtained by the imaging techniques can help in disease management. The algorithm used here automatically extracts clinical features such as anterior chamber width, iris endpoint width, chamber height, lens vault, angle opening distance, and trabecular iris angle from AS-OCT images to find the condition of eye, namely, the presence or absence of glaucoma.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Arevalo JF, Krivoy D, Fernandez CF (2009) How does optical coherence tomography work basic principles. In: Arevalo JF (ed) Retinal angiography and optical coherence tomography Springer, New York, NY Arevalo JF, Krivoy D, Fernandez CF (2009) How does optical coherence tomography work basic principles. In: Arevalo JF (ed) Retinal angiography and optical coherence tomography Springer, New York, NY
2.
go back to reference Campbell P, Redmond T, Agarwal R, Marshal LR, Evans BJ (2015) Repeatability and comparison of clinical techniques for anterior chamber angle assessment. Ophthalmic Physiol Opt 35(2):170–178CrossRef Campbell P, Redmond T, Agarwal R, Marshal LR, Evans BJ (2015) Repeatability and comparison of clinical techniques for anterior chamber angle assessment. Ophthalmic Physiol Opt 35(2):170–178CrossRef
3.
go back to reference Filipe HP, Carvalho M, Freitas MDL, Correa ZM (2016) Ultrasound biomicroscopy and anterior segment optical coherence tomography in the diagnosis and management of glaucoma. Vision Pan-Am Pan-Am J Ophthalmol 15(2):37–42 Filipe HP, Carvalho M, Freitas MDL, Correa ZM (2016) Ultrasound biomicroscopy and anterior segment optical coherence tomography in the diagnosis and management of glaucoma. Vision Pan-Am Pan-Am J Ophthalmol 15(2):37–42
5.
go back to reference Fu H, Xu Y, Lin S, Zhang X, Wong DWK, Liu J, Frangi AF, Baskaran M, Aung T (2017) Segmentation and quantification for angle-closure glaucoma assessment in anterior segment OCT. IEEE Trans Med Imag 36(9):109–117CrossRef Fu H, Xu Y, Lin S, Zhang X, Wong DWK, Liu J, Frangi AF, Baskaran M, Aung T (2017) Segmentation and quantification for angle-closure glaucoma assessment in anterior segment OCT. IEEE Trans Med Imag 36(9):109–117CrossRef
6.
go back to reference Ang M, Chong W, Tay WT, Yuen L, Wong TY, He M-G, Mehta JS (2012) Anterior segment optical coherence tomography study of the cornea and anterior segment in adult ethnic South Asian Indian eyes. Investig Ophthalmol Visual Sci 53(1):120–125CrossRef Ang M, Chong W, Tay WT, Yuen L, Wong TY, He M-G, Mehta JS (2012) Anterior segment optical coherence tomography study of the cornea and anterior segment in adult ethnic South Asian Indian eyes. Investig Ophthalmol Visual Sci 53(1):120–125CrossRef
7.
go back to reference Ni SN, Marziliano P, Wong H-T (2014) Angle closure glaucoma detection using fractal dimension index on SS-OCT images. In: 36th international conference of the IEEE engineering in medicine and biology society, Chicago, USA, pp 3885–3888 Ni SN, Marziliano P, Wong H-T (2014) Angle closure glaucoma detection using fractal dimension index on SS-OCT images. In: 36th international conference of the IEEE engineering in medicine and biology society, Chicago, USA, pp 3885–3888
Metadata
Title
Detection of Glaucoma Using Anterior Segment Optical Coherence Tomography Images
Authors
P. Priyanka
V. Norris Juliet
S. Shenbaga Devi
Copyright Year
2019
DOI
https://doi.org/10.1007/978-3-030-04061-1_30