Skip to main content
Top
Published in: Experiments in Fluids 3/2004

01-03-2004 | Original

Development and validation of echo PIV

Authors: H. B. Kim, J. R. Hertzberg, R. Shandas

Published in: Experiments in Fluids | Issue 3/2004

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase the spatial resolution of the velocity measurement to a maximum of 1.8 mm×3.1 mm. Velocity validation tests in fully developed laminar pipe flow showed good agreement with both optical PIV measurements and the expected parabolic profile. A dynamic range of 1 to 60 cm/s has been obtained to date.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Adrian RJ (1991) Particle-imaging techniques for experimental fluid mechanics. Ann Rev Fluid Mech 23:261–304CrossRef Adrian RJ (1991) Particle-imaging techniques for experimental fluid mechanics. Ann Rev Fluid Mech 23:261–304CrossRef
go back to reference Atkinson P, Woodcock JP (1982) Doppler ultrasound and its use in clinical measurement. Academic, New York Atkinson P, Woodcock JP (1982) Doppler ultrasound and its use in clinical measurement. Academic, New York
go back to reference Bamber J, Hasan P, Cook-Martin J, Rubim JM (1988) Parametric imaging of tissue shear and flow using B-scan decorrelation rate. J Ultrasound Med 7:s135 Bamber J, Hasan P, Cook-Martin J, Rubim JM (1988) Parametric imaging of tissue shear and flow using B-scan decorrelation rate. J Ultrasound Med 7:s135
go back to reference Bohs LN, Friemel BH, McDermott BA, Trahey GE (1993) A real time system for quantifying and displaying two-dimensional velocities using ultrasound. Ultrasound Med Biol 19:751–761PubMed Bohs LN, Friemel BH, McDermott BA, Trahey GE (1993) A real time system for quantifying and displaying two-dimensional velocities using ultrasound. Ultrasound Med Biol 19:751–761PubMed
go back to reference Bohs LN, Friemel BH, Trahey GE (1995) Experimental velocity profiles and volumetric flow via two-dimensional speckle tracking. Ultrasound Med Biol 21:885–898CrossRefPubMed Bohs LN, Friemel BH, Trahey GE (1995) Experimental velocity profiles and volumetric flow via two-dimensional speckle tracking. Ultrasound Med Biol 21:885–898CrossRefPubMed
go back to reference Bohs LN, Geiman BJ, Anderson ME, Gebhart SC, Trahey GE (2000) Speckle tracking for multi-dimensional flow estimation. Ultrasonics 38:369–375CrossRefPubMed Bohs LN, Geiman BJ, Anderson ME, Gebhart SC, Trahey GE (2000) Speckle tracking for multi-dimensional flow estimation. Ultrasonics 38:369–375CrossRefPubMed
go back to reference Crapper M, Bruce T, Gouble C (2000) Flow field visualization of sediment-laden flow using ultrasonic imaging. Dyn Atmos Oceans 31:233–245CrossRef Crapper M, Bruce T, Gouble C (2000) Flow field visualization of sediment-laden flow using ultrasonic imaging. Dyn Atmos Oceans 31:233–245CrossRef
go back to reference Fillinger MF, Schwartz RA (1993) Volumetric blood flow measurement with color Doppler ultrasonography: the importance of visual clues. J Ultrasound Med 3:123–130 Fillinger MF, Schwartz RA (1993) Volumetric blood flow measurement with color Doppler ultrasonography: the importance of visual clues. J Ultrasound Med 3:123–130
go back to reference Forsberg F, Merton DA, Liu JB, Needleman L, Goldberg BB (1998) Clinical applications of ultrasound contrast agents. Ultrasonics 36:695–701CrossRefPubMed Forsberg F, Merton DA, Liu JB, Needleman L, Goldberg BB (1998) Clinical applications of ultrasound contrast agents. Ultrasonics 36:695–701CrossRefPubMed
go back to reference Gill RW (1985) Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol 11:625–641PubMed Gill RW (1985) Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol 11:625–641PubMed
go back to reference Hart DP (1999) Super-resolution PIV by recursive local-correlation. J Visualiz 10:1–10 Hart DP (1999) Super-resolution PIV by recursive local-correlation. J Visualiz 10:1–10
go back to reference Keane RD, Adrian RJ (1990) Optimization of particle image velocimeters. Meas Sci Tech 2:1202–1215CrossRef Keane RD, Adrian RJ (1990) Optimization of particle image velocimeters. Meas Sci Tech 2:1202–1215CrossRef
go back to reference Kremkau FW (1989) Diagnostic ultrasound. WB Saunders, Philadelphia Kremkau FW (1989) Diagnostic ultrasound. WB Saunders, Philadelphia
go back to reference Leen E (2001) Ultrasound contrast harmonic imaging of abdominal organs. Seminars Ultrasound CT MRI 22:11–24 Leen E (2001) Ultrasound contrast harmonic imaging of abdominal organs. Seminars Ultrasound CT MRI 22:11–24
go back to reference Okamoto K (1999) Checker board cross-correlation technique for PIV. In: Proc Of PSFVIP-2, Honolulu, no. PF116 Okamoto K (1999) Checker board cross-correlation technique for PIV. In: Proc Of PSFVIP-2, Honolulu, no. PF116
go back to reference Podell S, Burrascano C, Gaal M, Golec B, Maniquis J, Mehlhaff P (1999) Physical and biochemical stability of Optison, an injectable ultrasound contrast agent. Biotechnol Appl Biochem 30:213–223PubMed Podell S, Burrascano C, Gaal M, Golec B, Maniquis J, Mehlhaff P (1999) Physical and biochemical stability of Optison, an injectable ultrasound contrast agent. Biotechnol Appl Biochem 30:213–223PubMed
go back to reference Rubin JM, Fowlkes JB, Tuthill TA, Moskalik AP, Rhee RT, Adler RS, Kazanjian SN, Carson PL (1999) Speckle decorrelation flow measurement with B-mode US of contrast agent flow in a phantom and in rabbit kidney. Radiology 213:429–437PubMed Rubin JM, Fowlkes JB, Tuthill TA, Moskalik AP, Rhee RT, Adler RS, Kazanjian SN, Carson PL (1999) Speckle decorrelation flow measurement with B-mode US of contrast agent flow in a phantom and in rabbit kidney. Radiology 213:429–437PubMed
go back to reference Sandrin L, Manneville S, Fink M (2001) Ultrafast two-dimensional ultrasonic speckle velocimetry: a tool in flow imaging. Appl Phys Lett 78:1155–1157 Sandrin L, Manneville S, Fink M (2001) Ultrafast two-dimensional ultrasonic speckle velocimetry: a tool in flow imaging. Appl Phys Lett 78:1155–1157
go back to reference Schneider M (2000) Design of an ultrasound contrast agent for myocardial perfusion. Echocardiography 17:s11–s16PubMed Schneider M (2000) Design of an ultrasound contrast agent for myocardial perfusion. Echocardiography 17:s11–s16PubMed
go back to reference Tio KK, Linan A, Lasheras JC, Ganan-Calvo AM (1993) On the dynamics of buoyant and heavy particles in a periodic Stuart vortex flow. J Fluid Mech 254:671–699 Tio KK, Linan A, Lasheras JC, Ganan-Calvo AM (1993) On the dynamics of buoyant and heavy particles in a periodic Stuart vortex flow. J Fluid Mech 254:671–699
go back to reference Uhlendorf V, Scholle F, Reinhardt M (2000) Acoustic behavior of current ultrasound contrast agents. Ultrasonics 38:81–86CrossRefPubMed Uhlendorf V, Scholle F, Reinhardt M (2000) Acoustic behavior of current ultrasound contrast agents. Ultrasonics 38:81–86CrossRefPubMed
go back to reference Westerweel J (1993) Digital particle image velocimetry—theory and application. Dissertation, Delft University, The Netherlands Westerweel J (1993) Digital particle image velocimetry—theory and application. Dissertation, Delft University, The Netherlands
go back to reference Westerweel J, Dabiri D, Gharib M (1997) The effect of a discrete window offset on the accuracy of cross-correlation analysis of digital PIV recordings. Exp Fluids 23:20–28CrossRef Westerweel J, Dabiri D, Gharib M (1997) The effect of a discrete window offset on the accuracy of cross-correlation analysis of digital PIV recordings. Exp Fluids 23:20–28CrossRef
go back to reference Willert CE, Gharib M (1991) Digital particle image velocimetry. Exp Fluids 10:181–193 Willert CE, Gharib M (1991) Digital particle image velocimetry. Exp Fluids 10:181–193
Metadata
Title
Development and validation of echo PIV
Authors
H. B. Kim
J. R. Hertzberg
R. Shandas
Publication date
01-03-2004
Publisher
Springer-Verlag
Published in
Experiments in Fluids / Issue 3/2004
Print ISSN: 0723-4864
Electronic ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-003-0743-5

Other articles of this Issue 3/2004

Experiments in Fluids 3/2004 Go to the issue

Premium Partners