Skip to main content
Top

2015 | OriginalPaper | Chapter

6. Development of Tissue Surrogates for Photoelastic Strain Analysis of Needle Insertion

Authors : Rachel A. Tomlinson, Wei Kang Aui Yong, Guy Morton, Zeike A. Taylor

Published in: Mechanics of Biological Systems and Materials, Volume 7

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper focuses on the development of full-field experimental methods for validating computational models of needle insertion, and specifically the development of suitable tissue surrogate materials. Gelatine also known as “ballistic gel” is commonly used as a tissue surrogate since the modulus of elasticity matches that of tissue. Its birefringent properties also allow the visualisation of strains in polarised light. However, other characteristics of tissue are not well emulated by gelatine, for example the fibrous network of cells of tissue is not well represented by the granular microstructure of gelatine, which tears easily. A range of birefringent flexible materials were developed and calibrated for photoelastic analysis. The most suitable were then used to explore quantitatively the different strain distributions in tissue when subjected to a range of needles with different tip profiles.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Misra S, Reed KB, Schafer BW, Ramesh KT, Okamura AM (2010) Mechanics of flexible needles robotically steered through soft tissue. Int J Robot Res 29:1640–1660CrossRef Misra S, Reed KB, Schafer BW, Ramesh KT, Okamura AM (2010) Mechanics of flexible needles robotically steered through soft tissue. Int J Robot Res 29:1640–1660CrossRef
2.
go back to reference Jahya A, van der Heijden F, Misra S (2012) Observations of three-dimensional needle deflection during insertion into soft tissue. In: International conference on biomedical robotics and biomechatronics, Italy, June 2012, pp 1205–1210 Jahya A, van der Heijden F, Misra S (2012) Observations of three-dimensional needle deflection during insertion into soft tissue. In: International conference on biomedical robotics and biomechatronics, Italy, June 2012, pp 1205–1210
3.
go back to reference Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29:413–431CrossRef Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29:413–431CrossRef
4.
go back to reference Misra S, Reed KB, Douglas AS, Ramesh KT, Okamura, AM (2008) Needle-tissue interaction forces for bevel-tip steerable needles. National Institutes of Health, NIH Public Access, Scottsdale, pp 224–231 Misra S, Reed KB, Douglas AS, Ramesh KT, Okamura, AM (2008) Needle-tissue interaction forces for bevel-tip steerable needles. National Institutes of Health, NIH Public Access, Scottsdale, pp 224–231
5.
go back to reference Abayazid M, op den Buijs J, de Kortey CL, Misra S (2012) Effect of skin thickness on target motion during needle insertion into soft-tissue phantoms. In: The fourth IEEE RAS/EMBS international conference on biomedical robotics and biomechatronics, pp 755–760 Abayazid M, op den Buijs J, de Kortey CL, Misra S (2012) Effect of skin thickness on target motion during needle insertion into soft-tissue phantoms. In: The fourth IEEE RAS/EMBS international conference on biomedical robotics and biomechatronics, pp 755–760
6.
go back to reference Cronin DS, Falzon C (2010) Characterization of 10 % ballistic gelatin to evaluate temperature, aging and strain rate effects. Exp Mech 51:1197–1206CrossRef Cronin DS, Falzon C (2010) Characterization of 10 % ballistic gelatin to evaluate temperature, aging and strain rate effects. Exp Mech 51:1197–1206CrossRef
7.
go back to reference Kwon J, Subhash G (2010) Compressive strain rate sensitivity of ballistic gelatin. J Biomech 43(3):420–425CrossRef Kwon J, Subhash G (2010) Compressive strain rate sensitivity of ballistic gelatin. J Biomech 43(3):420–425CrossRef
8.
go back to reference Markidou A, Shih WY, Shih W (2005) Soft-materials elastic and shear moduli measurement using piezoelectric cantilevers. Am Inst Phys Rev Sci Instrum 76(3):064302CrossRef Markidou A, Shih WY, Shih W (2005) Soft-materials elastic and shear moduli measurement using piezoelectric cantilevers. Am Inst Phys Rev Sci Instrum 76(3):064302CrossRef
9.
go back to reference Thomazine M, Carvalho RA, Sobral PJA (2005) Physical properties of gelatine films plasticized by blends of glycerol and sorbitol. J Food Sci 70(3):E172–E176CrossRef Thomazine M, Carvalho RA, Sobral PJA (2005) Physical properties of gelatine films plasticized by blends of glycerol and sorbitol. J Food Sci 70(3):E172–E176CrossRef
10.
go back to reference Agache PG, Monneur C, Leveque JL, De Rigal J (1980) Mechanical properties and Young’s modulus of human skin in vivo. Arch Dermatol Res 269:221–232CrossRef Agache PG, Monneur C, Leveque JL, De Rigal J (1980) Mechanical properties and Young’s modulus of human skin in vivo. Arch Dermatol Res 269:221–232CrossRef
11.
go back to reference Edwards C, Marks R (1995) Evaluation of biomechanical properties of human skin. Clin Dermatol 13(4):375–380CrossRef Edwards C, Marks R (1995) Evaluation of biomechanical properties of human skin. Clin Dermatol 13(4):375–380CrossRef
12.
go back to reference Saraf H, Ramesh KT, Lennon AM, Merkle AC, Roberts JC (2007) Mechanical properties of soft human tissues under dynamic loading. J Biomech 40(9):1960–1967CrossRef Saraf H, Ramesh KT, Lennon AM, Merkle AC, Roberts JC (2007) Mechanical properties of soft human tissues under dynamic loading. J Biomech 40(9):1960–1967CrossRef
13.
go back to reference Davis SP, Landis BJ, Adams ZH, Allen MG, Prausnitz MR (2004) Insertion of microneedles into skin. J Biomech 37:1155–1163CrossRef Davis SP, Landis BJ, Adams ZH, Allen MG, Prausnitz MR (2004) Insertion of microneedles into skin. J Biomech 37:1155–1163CrossRef
14.
go back to reference Taylor D, O’Mara N, Ryan E, Takaza M, Simms C (2011) The fracture toughness of soft tissues. J Mech Behav Biomed Mater 6:139–147CrossRef Taylor D, O’Mara N, Ryan E, Takaza M, Simms C (2011) The fracture toughness of soft tissues. J Mech Behav Biomed Mater 6:139–147CrossRef
15.
go back to reference Cloud G (1995) Optical methods of engineering analysis. Cambridge University Press, CambridgeCrossRef Cloud G (1995) Optical methods of engineering analysis. Cambridge University Press, CambridgeCrossRef
16.
go back to reference Lacasse Y, Wong E, Guyatt GH, Cook DJ (1999) Transthoracic needle aspiration biopsy for the diagnosis of localised pulmonary lesions: a meta-analysis. Thorax 54:884–893CrossRef Lacasse Y, Wong E, Guyatt GH, Cook DJ (1999) Transthoracic needle aspiration biopsy for the diagnosis of localised pulmonary lesions: a meta-analysis. Thorax 54:884–893CrossRef
17.
go back to reference Benham PP, Crawford RJ, Armstrong CG (1996) Mechanics of engineering materials. Pearson, Essex, p 497 Benham PP, Crawford RJ, Armstrong CG (1996) Mechanics of engineering materials. Pearson, Essex, p 497
18.
go back to reference van Gerwen DJ, Dankelman J, van den Dobbelsteen JJ (2012) Needle–tissue interaction forces – a survey of experimental data. Med Eng Phys 34:665–680CrossRef van Gerwen DJ, Dankelman J, van den Dobbelsteen JJ (2012) Needle–tissue interaction forces – a survey of experimental data. Med Eng Phys 34:665–680CrossRef
Metadata
Title
Development of Tissue Surrogates for Photoelastic Strain Analysis of Needle Insertion
Authors
Rachel A. Tomlinson
Wei Kang Aui Yong
Guy Morton
Zeike A. Taylor
Copyright Year
2015
DOI
https://doi.org/10.1007/978-3-319-06974-6_6