Skip to main content
Top

2020 | OriginalPaper | Chapter

Difference Between 50 and 60 Hz Transformer No-Load Noise Levels

Author : Miha Pirnat

Published in: 5th International Colloquium on Transformer Research and Asset Management

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

An unexplained difference between noise levels of 50 and 60 Hz transformers was presented in the previous published work of CIGRE workgroup A2.54 titled ‘No-load sound power levels for specification purposes derived from more than 1000 measurements–a representative figure for three-phase transformers’. The purpose of this paper is to provide further explanation of this phenomenon based on predictable and unpredictable effects, which are the source of the observed no-load noise difference between 50 and 60 Hz transformers.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Ploetner C (2017) No-load sound power levels for specification purposes derived from more than 1000 measurements–a representative figure for three phase transformers. In: Proceedings from CIGRE study committee A2 colloquium. Cracow, 1st–6th, Oct 2017 Ploetner C (2017) No-load sound power levels for specification purposes derived from more than 1000 measurements–a representative figure for three phase transformers. In: Proceedings from CIGRE study committee A2 colloquium. Cracow, 1st–6th, Oct 2017
2.
go back to reference Fahy F, Gardonio P (2007) Sound and structural vibration: radiation, transmission and response. Elsevier Fahy F, Gardonio P (2007) Sound and structural vibration: radiation, transmission and response. Elsevier
Metadata
Title
Difference Between 50 and 60 Hz Transformer No-Load Noise Levels
Author
Miha Pirnat
Copyright Year
2020
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-15-5600-5_2