Nitinol is used as a metallic biomaterial in medical devices due to its shape memory and pseudoelastic properties. The clinical performance of nitinol depends on factors which include the surface finish, the local environment, and the mechanical loads to which the device is subjected. Preclinical evaluations of device durability are performed with fatigue tests while electrochemical characterization methods such as ASTM F2129 are employed to evaluate corrosion susceptibility by determining the rest potential and breakdown potential. However, it is well established that the rest potential of a metal surface can vary with the local environment. Very little is known regarding the influence of voltage on fatigue life of nitinol. In this study, we developed a fatigue testing method in which an electrochemical system was integrated with a rotary bend wire fatigue tester. Samples were fatigued at various strain levels at electropotentials anodic and cathodic to the rest potential to determine if it could influence fatigue life. Wires at potentials negative to the rest potential had a significantly higher number of cycles to fracture than wires held at potentials above the breakdown potential. For wires for which no potential was applied, they had fatigue life similar to wires at negative potentials.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Duerig T, Tolomeo D, Wholey M (2000) An overview of superelastic stent design. Minim Invasive Ther Allied Technol 9(3–4):235–246CrossRef Duerig T, Tolomeo D, Wholey M (2000) An overview of superelastic stent design. Minim Invasive Ther Allied Technol 9(3–4):235–246CrossRef
2.
go back to reference Adlakha S, Sheikh M, Wu J, Burket MW, Pandya U, Colyer W, Eltahawy E, Cooper CJ (2010) Stent fracture in the coronary and peripheral arteries. J Interv Cardiol 23(4):411–419CrossRef Adlakha S, Sheikh M, Wu J, Burket MW, Pandya U, Colyer W, Eltahawy E, Cooper CJ (2010) Stent fracture in the coronary and peripheral arteries. J Interv Cardiol 23(4):411–419CrossRef
3.
go back to reference Chakravarty T, White AJ, Buch M, Naik H, Doctor N, Schapira J, Kar S, Forrester JS, Weiss RE, Makkar R (2010) Meta-analysis of incidence, clinical characteristics and implications of stent fracture. Am J Cardiol 106(8):1075–1080CrossRef Chakravarty T, White AJ, Buch M, Naik H, Doctor N, Schapira J, Kar S, Forrester JS, Weiss RE, Makkar R (2010) Meta-analysis of incidence, clinical characteristics and implications of stent fracture. Am J Cardiol 106(8):1075–1080CrossRef
4.
go back to reference Haas A (2007) The phagosome: compartment with a license to kill. Traffic 8(4):311–330CrossRef Haas A (2007) The phagosome: compartment with a license to kill. Traffic 8(4):311–330CrossRef
5.
go back to reference Shabalovskaya SA, Anderegg JW, Undisz A, Rettenmayr M, Rondelli GC (2012) Corrosion resistance, chemistry, and mechanical aspects of nitinol surfaces formed in hydrogen peroxide solutions. J Biomed Mater Res B Appl Biomater 100(6):1490–1499CrossRef Shabalovskaya SA, Anderegg JW, Undisz A, Rettenmayr M, Rondelli GC (2012) Corrosion resistance, chemistry, and mechanical aspects of nitinol surfaces formed in hydrogen peroxide solutions. J Biomed Mater Res B Appl Biomater 100(6):1490–1499CrossRef
6.
go back to reference Swaminathan V, Gilbert JL (2012) Fretting corrosion of CoCrMo and Ti6Al4 V interfaces. Biomaterials 33(22):5487–5503CrossRef Swaminathan V, Gilbert JL (2012) Fretting corrosion of CoCrMo and Ti6Al4 V interfaces. Biomaterials 33(22):5487–5503CrossRef
7.
go back to reference Wazni O, Wilkoff BL (2016) Considerations for cardiac device lead extraction. Nat Rev Cardiol 13(4):221–229CrossRef Wazni O, Wilkoff BL (2016) Considerations for cardiac device lead extraction. Nat Rev Cardiol 13(4):221–229CrossRef
8.
go back to reference Nichols CI, Vose JG, Mittal S (2016) Incidence and costs related to lead damage occurring within the first year after a cardiac implantable electronic device replacement procedure. J Am Heart Assoc 5(2):e002813 Nichols CI, Vose JG, Mittal S (2016) Incidence and costs related to lead damage occurring within the first year after a cardiac implantable electronic device replacement procedure. J Am Heart Assoc 5(2):e002813
9.
go back to reference Shah AD, Hirsh DS, Langberg JJ (2016) Sudden and fatal malfunction of a durata defibrillator lead due to external insulation failure. Pacing Clin Electrophysiol 39(1):101–104CrossRef Shah AD, Hirsh DS, Langberg JJ (2016) Sudden and fatal malfunction of a durata defibrillator lead due to external insulation failure. Pacing Clin Electrophysiol 39(1):101–104CrossRef
10.
go back to reference Lim KK, Reddy S, Desai S, Smelley M, Kim SS, Beshai JF, Lin AC, Burke MC, Knight BP (2009) Effects of electrocautery on transvenous lead insulation materials. J Cardiovasc Electrophysiol 20(4):429–435CrossRef Lim KK, Reddy S, Desai S, Smelley M, Kim SS, Beshai JF, Lin AC, Burke MC, Knight BP (2009) Effects of electrocautery on transvenous lead insulation materials. J Cardiovasc Electrophysiol 20(4):429–435CrossRef
11.
go back to reference Eng LK, Walters TE, Gould PA (2012) Implantable cardioverter-defibrillator failure unmasked by a “lucky” shock. J Arrhythm 28(4):254–257CrossRef Eng LK, Walters TE, Gould PA (2012) Implantable cardioverter-defibrillator failure unmasked by a “lucky” shock. J Arrhythm 28(4):254–257CrossRef
12.
go back to reference Hauser RG, McGriff D, Retel LK (2012) Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect. Heart Rhythm 9(5):742–749CrossRef Hauser RG, McGriff D, Retel LK (2012) Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect. Heart Rhythm 9(5):742–749CrossRef
13.
go back to reference Kanemura T, Yokoyama KI, Sakai JI (2008) Effects of acid type on corrosion and fracture behavior of Ni–Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide. Corros Sci 50(10):2785–2795CrossRef Kanemura T, Yokoyama KI, Sakai JI (2008) Effects of acid type on corrosion and fracture behavior of Ni–Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide. Corros Sci 50(10):2785–2795CrossRef
14.
go back to reference Yokoyama KI, Ogawa T, Fujita A, Asaoka K, Sakai JI (2007) Fracture of Ni-Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide. J Biomed Mater Res Part A 82(3):558–567CrossRef Yokoyama KI, Ogawa T, Fujita A, Asaoka K, Sakai JI (2007) Fracture of Ni-Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide. J Biomed Mater Res Part A 82(3):558–567CrossRef
15.
go back to reference Gilbert JL, Sivan S, Liu Y, Kocagöz SB, Arnholt CM, Kurtz SM (2015) Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J Biomed Mater Res Part A 103(1):211–223CrossRef Gilbert JL, Sivan S, Liu Y, Kocagöz SB, Arnholt CM, Kurtz SM (2015) Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J Biomed Mater Res Part A 103(1):211–223CrossRef
16.
go back to reference Lonn MK, Metcalf JM, Choules BD (2015) In vivo and in vitro nitinol corrosion properties. Shape Mem Superelasticity 1(3):328–338CrossRef Lonn MK, Metcalf JM, Choules BD (2015) In vivo and in vitro nitinol corrosion properties. Shape Mem Superelasticity 1(3):328–338CrossRef
17.
go back to reference Ehrensberger MT, Gilbert JL (2010) The effect of static applied potential on the 24-hour impedance behavior of commercially pure titanium in simulated biological conditions. J Biomed Mater Res B Appl Biomater 93(1):106–112 Ehrensberger MT, Gilbert JL (2010) The effect of static applied potential on the 24-hour impedance behavior of commercially pure titanium in simulated biological conditions. J Biomed Mater Res B Appl Biomater 93(1):106–112
18.
go back to reference Sullivan SJ, Dreher ML, Zheng J, Chen L, Madamba D, Miyashiro K, Trépanier C, Nagaraja S (2015) Effects of oxide layer composition and radial compression on nickel release in nitinol stents. Shape Mem Superelasticity 1(3):319–327CrossRef Sullivan SJ, Dreher ML, Zheng J, Chen L, Madamba D, Miyashiro K, Trépanier C, Nagaraja S (2015) Effects of oxide layer composition and radial compression on nickel release in nitinol stents. Shape Mem Superelasticity 1(3):319–327CrossRef
19.
go back to reference Racek J, Stora M, Šittner P, Heller L, Kopeček J, Petrenec M (2015) Monitoring tensile fatigue of superelastic NiTi wire in liquids by electrochemical potential. Shape Mem Superelasticity 1(2):204–230CrossRef Racek J, Stora M, Šittner P, Heller L, Kopeček J, Petrenec M (2015) Monitoring tensile fatigue of superelastic NiTi wire in liquids by electrochemical potential. Shape Mem Superelasticity 1(2):204–230CrossRef
20.
go back to reference ASTM-F2129-15 (2015) Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices. ASTM International, West Conshohocken ASTM-F2129-15 (2015) Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices. ASTM International, West Conshohocken
21.
go back to reference ASTM-E2948-16a (2016) Standard test method for conducting rotating bending fatigue test of solid round fine wire. ASTM International, West Conshohocken ASTM-E2948-16a (2016) Standard test method for conducting rotating bending fatigue test of solid round fine wire. ASTM International, West Conshohocken
22.
go back to reference Di Prima M, Gutierrez E, Weaver JD (2016) The effect of fatigue on the corrosion resistance of common medical alloys. J Biomed Mater Res Part B. doi:10.1002/jbm.b.33738 Di Prima M, Gutierrez E, Weaver JD (2016) The effect of fatigue on the corrosion resistance of common medical alloys. J Biomed Mater Res Part B. doi:10.​1002/​jbm.​b.​33738
23.
go back to reference Neelakantan L, Zglinski JK, Frotscher M, Eggeler G (2013) Design and fabrication of a bending rotation fatigue test rig for in situ electrochemical analysis during fatigue testing of NiTi shape memory alloy wires. Rev Sci Instrum 84(3):035102CrossRef Neelakantan L, Zglinski JK, Frotscher M, Eggeler G (2013) Design and fabrication of a bending rotation fatigue test rig for in situ electrochemical analysis during fatigue testing of NiTi shape memory alloy wires. Rev Sci Instrum 84(3):035102CrossRef
24.
go back to reference Farb A, Sangiorgi G, Carter AJ, Walley VM, Edwards WD, Schwartz RS, Virmani R (1999) Pathology of acute and chronic coronary stenting in humans. Circulation 99(1):44–52CrossRef Farb A, Sangiorgi G, Carter AJ, Walley VM, Edwards WD, Schwartz RS, Virmani R (1999) Pathology of acute and chronic coronary stenting in humans. Circulation 99(1):44–52CrossRef
25.
go back to reference Pound BG (2010) Electrochemical behavior of cobalt–chromium alloys in a simulated physiological solution. J Biomed Mater Res Part A 94A(1):93–102CrossRef Pound BG (2010) Electrochemical behavior of cobalt–chromium alloys in a simulated physiological solution. J Biomed Mater Res Part A 94A(1):93–102CrossRef
Metadata
Title
Effect of Applied Potential on Fatigue Life of Electropolished Nitinol Wires
Authors
Shiril Sivan
Matthew Di Prima
Jason D. Weaver
Publication date
22-06-2017
Publisher
Springer International Publishing
Published in
Shape Memory and Superelasticity / Issue 3/2017
Print ISSN: 2199-384X
Electronic ISSN: 2199-3858
DOI
https://doi.org/10.1007/s40830-017-0109-0

Other articles of this Issue 3/2017

Shape Memory and Superelasticity 3/2017 Go to the issue

Special Issue: ICFSMA 2016, Invited Paper

Effect of Annealing on Elastic Moduli of a FSMA

Premium Partners