Effect of Arrangement and Number of Water Mist Spray Nozzles on Air Humidity

Authors : Pravinth Balthazar, Mohd Azmi Ismail, Andyqa Abdul Wahab, Mohammad Nazmi Nasir, Muhammad Iftishah Ramdan, Hussin Bin Mamat

Published in: Intelligent Manufacturing and Energy Sustainability

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Water spray technique is used in many applications like cooling, humidifying, and firefighting applications. The performances of 1, 4, and 9 number of nozzles under horizontal parallel, counter, and vertical flow arrangement have been experimentally analyzed for air volume flow rate from 0.34 to 2.15 m3/s, room temperature from 28.5 to 30.2 °C, and relative humidity between 59 and 78%. The data show clear trend between relative humidity and number of nozzles. 9.5, 10.5, and 20% higher humidification by percentage achieved for the highest number of nozzles than lower number of nozzles in vertical, parallel, and counter flow arrangement, respectively. However, flow evaporation is greatly affected than mist evaporation performance under parallel flow placement at single-nozzle arrangement. Vertical arrangement with 9 nozzles showed 20.3% higher relative humidity than 1 nozzle under counter flow arrangement.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Chengqin, R., Nianping, L., Guangfa, T.: Principles of exergy analysis in HVAC and evaluation of evaporative cooling schemes. Build. Environ. 37(11), 1045–1055 (2002)CrossRef Chengqin, R., Nianping, L., Guangfa, T.: Principles of exergy analysis in HVAC and evaluation of evaporative cooling schemes. Build. Environ. 37(11), 1045–1055 (2002)CrossRef
2.
go back to reference Cerci, Y.: A new ideal evaporative freezing cycle. Int. J. Heat Mass Transf. 46(16), 2967–2974 (2003)CrossRef Cerci, Y.: A new ideal evaporative freezing cycle. Int. J. Heat Mass Transf. 46(16), 2967–2974 (2003)CrossRef
3.
go back to reference Wong, N.H., Chong, A.Z.: Performance evaluation of misting fans in hot and humid climate. Build. Environ. 45(12), 2666–2678 (2010)CrossRef Wong, N.H., Chong, A.Z.: Performance evaluation of misting fans in hot and humid climate. Build. Environ. 45(12), 2666–2678 (2010)CrossRef
4.
go back to reference Nishimura, N., Nomura, T., Iyota, H., Kimoto, S.: Novel water facilities for creation of comfortable urban micrometeorology. Sol. Energy 64(4–6), 197–207 (1998)CrossRef Nishimura, N., Nomura, T., Iyota, H., Kimoto, S.: Novel water facilities for creation of comfortable urban micrometeorology. Sol. Energy 64(4–6), 197–207 (1998)CrossRef
5.
go back to reference Calautit, J.K., Chaudhry, H.N., Hughes, B.R., Ghani, S.A.: Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions. Appl. Energy 101, 740–755 (2013)CrossRef Calautit, J.K., Chaudhry, H.N., Hughes, B.R., Ghani, S.A.: Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions. Appl. Energy 101, 740–755 (2013)CrossRef
6.
go back to reference Wei, J., He, J.: Numerical simulation for analyzing the thermal improving effect of evaporative cooling urban surfaces on the urban built environment. Appl. Therm. Eng. 51(1–2), 144–154 (2013)CrossRef Wei, J., He, J.: Numerical simulation for analyzing the thermal improving effect of evaporative cooling urban surfaces on the urban built environment. Appl. Therm. Eng. 51(1–2), 144–154 (2013)CrossRef
7.
go back to reference Muangnoi, T., Asvapoositkul, W., Wongwises, S.: Effects of inlet relative humidity and inlet temperature on the performance of counterflow wet cooling tower based on exergy analysis. Energy Convers. Manag. 49(10), 2795–2800 (2013)CrossRef Muangnoi, T., Asvapoositkul, W., Wongwises, S.: Effects of inlet relative humidity and inlet temperature on the performance of counterflow wet cooling tower based on exergy analysis. Energy Convers. Manag. 49(10), 2795–2800 (2013)CrossRef
8.
go back to reference Kachhwaha, S.S., Dhar, P.L., Kale, S.R.: Experimental studies and numerical simulation of evaporative cooling of air with a water spray-I. Horizontal parallel flow. Int. J. Heat. Mass. Transf. 41(2), 447–464 (1998)CrossRef Kachhwaha, S.S., Dhar, P.L., Kale, S.R.: Experimental studies and numerical simulation of evaporative cooling of air with a water spray-I. Horizontal parallel flow. Int. J. Heat. Mass. Transf. 41(2), 447–464 (1998)CrossRef
9.
go back to reference Kachhwaha, S.S., Dhar, P.L., Kale, S.R.: Experimental studies and numerical simulation of evaporative cooling of air with a water spray-II. Horizontal counter flow. Int. J. Heat. Mass. Transf. 41(2), 465–474 (1998)CrossRef Kachhwaha, S.S., Dhar, P.L., Kale, S.R.: Experimental studies and numerical simulation of evaporative cooling of air with a water spray-II. Horizontal counter flow. Int. J. Heat. Mass. Transf. 41(2), 465–474 (1998)CrossRef
10.
go back to reference Sureshkumar, R., Kale, S.R., Dhar, P.L.: Heat and mass transfer processes between a water spray and ambient air–I. Experimental data. Appl. Therm. Eng. 28(5–6), 349–360 (2008)CrossRef Sureshkumar, R., Kale, S.R., Dhar, P.L.: Heat and mass transfer processes between a water spray and ambient air–I. Experimental data. Appl. Therm. Eng. 28(5–6), 349–360 (2008)CrossRef
11.
go back to reference Sureshkumar, R., Kale, S.R., Dhar, P.L.: Heat and mass transfer processes between a water spray and ambient air–II. Simulations. Appl. Therm. Eng. 28(5–6), 361–371 (2008)CrossRef Sureshkumar, R., Kale, S.R., Dhar, P.L.: Heat and mass transfer processes between a water spray and ambient air–II. Simulations. Appl. Therm. Eng. 28(5–6), 361–371 (2008)CrossRef
12.
go back to reference Belarbi, R., Ghiaus, C., Allard, F.: Modeling of water spray evaporation: application to passive cooling of buildings. Sol. Energy 80(12), 1540–1552 (2006)CrossRef Belarbi, R., Ghiaus, C., Allard, F.: Modeling of water spray evaporation: application to passive cooling of buildings. Sol. Energy 80(12), 1540–1552 (2006)CrossRef
13.
go back to reference Husted, B.P., Petersson, P., Lund, I., Holmstedt, G.: Comparison of PIV and PDA droplet velocity measurement techniques on two high-pressure water mist nozzles. Fire Saf. J. 44(8), 1030–1045 (2009)CrossRef Husted, B.P., Petersson, P., Lund, I., Holmstedt, G.: Comparison of PIV and PDA droplet velocity measurement techniques on two high-pressure water mist nozzles. Fire Saf. J. 44(8), 1030–1045 (2009)CrossRef
14.
go back to reference Montazeri, H., Blocken, B., Hensen, J.L.: CFD analysis of the impact of physical parameters on evaporative cooling by a mist spray system. Appl. Therm. Eng. 75, 608–622 (2015)CrossRef Montazeri, H., Blocken, B., Hensen, J.L.: CFD analysis of the impact of physical parameters on evaporative cooling by a mist spray system. Appl. Therm. Eng. 75, 608–622 (2015)CrossRef
15.
go back to reference Montazeri, H., Blocken, B., Hensen, J.L.M.: Evaporative cooling by water spray systems: CFD simulation, experimental validation and sensitivity analysis. Build. Environ. 83, 129–141 (2015)CrossRef Montazeri, H., Blocken, B., Hensen, J.L.M.: Evaporative cooling by water spray systems: CFD simulation, experimental validation and sensitivity analysis. Build. Environ. 83, 129–141 (2015)CrossRef
16.
go back to reference Alkhedhair, A., Jahn, I., Gurgenci, H., Guan, Z., He, S., Lu, Y.: Numerical simulation of water spray in natural draft dry cooling towers with a new nozzle representation approach. Appl. Therm. Eng. 98, 924–935 (2016)CrossRef Alkhedhair, A., Jahn, I., Gurgenci, H., Guan, Z., He, S., Lu, Y.: Numerical simulation of water spray in natural draft dry cooling towers with a new nozzle representation approach. Appl. Therm. Eng. 98, 924–935 (2016)CrossRef
17.
go back to reference Balthazar, P., Ismail, M.A., Soberi, A.S.B.A., Muhammad Iftishah, R., Hussin, M.: Experimental study of the effect of piccolo tube pipe on the air-conditioning experimental rig. J. Adv. Res. Fluid Mech. Therm. Sci. 53(1), 95–105 (2019) Balthazar, P., Ismail, M.A., Soberi, A.S.B.A., Muhammad Iftishah, R., Hussin, M.: Experimental study of the effect of piccolo tube pipe on the air-conditioning experimental rig. J. Adv. Res. Fluid Mech. Therm. Sci. 53(1), 95–105 (2019)
Metadata
Title
Effect of Arrangement and Number of Water Mist Spray Nozzles on Air Humidity
Authors
Pravinth Balthazar
Mohd Azmi Ismail
Andyqa Abdul Wahab
Mohammad Nazmi Nasir
Muhammad Iftishah Ramdan
Hussin Bin Mamat
Copyright Year
2020
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-15-1616-0_12

Premium Partners