Abstract

With 110 kV oil-immersed transformer as the platform, in this paper, we build a full-scale test platform covering 6 fire extinguishing (fire control) methods and different extinguishing agents, which is available for transformer fire extinguishing tests consistent with actual fire conditions. Through a transformer fire extinguishing test consistent with the real situation, we can draw that the efficiencies of different fire extinguishing methods from high to low are: fire monitor, foam fire extinguishing system (column type), water spray fire extinguishing system, foam fire extinguishing system (pipe network type), water mist fire extinguishing system, oil discharge and nitrogen injection system; Based on simulation calculations and full-scale test results, we evaluate the effectiveness of the transformer fire extinguishing systems by using the combined weight method and taking into overall consideration of factors such as fire extinguishing effect, fire extinguishing cost, system reliability, environmental protection, etc.. It is concluded that the recommended fire extinguishing methods for oil-immersed transformers from superior to inferior are in the sequences of: fire monitor system with oil-emulsified extinguishing agent, foam system with oil-emulsified extinguishing agent (column type), water spray system with oil-emulsified extinguishing agent, foam system (pipe network type), water mist system with foam extinguishing agent, oil discharge and nitrogen injection system. The conclusion provides a reference for the selection of fire extinguishing methods for oil-immersed transformers.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Wu C, Zhou T, Chen B et al (2021) Experimental study on burning characteristics of the large-scale transformer oil pool fire with different extinguishing methods. Fire Technol 57(1):461–481CrossRef Wu C, Zhou T, Chen B et al (2021) Experimental study on burning characteristics of the large-scale transformer oil pool fire with different extinguishing methods. Fire Technol 57(1):461–481CrossRef
2.
go back to reference Duarte D (2004) A performance overview about fire risk management in the Brazilian hydroelectric generating plants and transmission network. J Loss Prev Process Ind 17(1):65–75CrossRef Duarte D (2004) A performance overview about fire risk management in the Brazilian hydroelectric generating plants and transmission network. J Loss Prev Process Ind 17(1):65–75CrossRef
3.
go back to reference Liu Y, Chen B, Wu C et al (2020) Development of actual transformer fire-extinguishing test platform and coupling fire-extinguishing test. Fire Sci Technol 39(7):966–969 Liu Y, Chen B, Wu C et al (2020) Development of actual transformer fire-extinguishing test platform and coupling fire-extinguishing test. Fire Sci Technol 39(7):966–969
4.
go back to reference Ng AKL (2007) Risk assessment of transformer fire protection in a typical New Zealand high-rise building. Research Thesis, University of Canterbury Ng AKL (2007) Risk assessment of transformer fire protection in a typical New Zealand high-rise building. Research Thesis, University of Canterbury
5.
go back to reference Geoff Lesh PE (2010) Report on the step-up transformer failure and fire at palomar unit 1-December 2010 August 10, 2011 business meeting discussion item. Engineering Office Siting, Transmission and Environmental Protection Division, California Geoff Lesh PE (2010) Report on the step-up transformer failure and fire at palomar unit 1-December 2010 August 10, 2011 business meeting discussion item. Engineering Office Siting, Transmission and Environmental Protection Division, California
6.
go back to reference Wang Y, Li C, Zhang J et al (2019) Fire accident characteristics and fire extinguishing countermeasures of oil-immersed transformer. Saf Environ Eng 11(6):166–171 (In Chinese) Wang Y, Li C, Zhang J et al (2019) Fire accident characteristics and fire extinguishing countermeasures of oil-immersed transformer. Saf Environ Eng 11(6):166–171 (In Chinese)
7.
go back to reference Wang Y, Li C, Zhang J et al (2019) Fire accident characteristics and fire extinguishing countermeasures of oil-immersed transformer. Saf Environ Eng 26(6):166–171 (In Chinese) Wang Y, Li C, Zhang J et al (2019) Fire accident characteristics and fire extinguishing countermeasures of oil-immersed transformer. Saf Environ Eng 26(6):166–171 (In Chinese)
8.
go back to reference Lu J, Chen B, Liang P et al (2019) Experimental evaluation of protecting high-voltage electrical transformers using water mist with and without additives. Fire Technol 1(1):1–20 Lu J, Chen B, Liang P et al (2019) Experimental evaluation of protecting high-voltage electrical transformers using water mist with and without additives. Fire Technol 1(1):1–20
9.
go back to reference Han Y, Choi B, Kim M (2005) Application of a fixed water mist system in a power transformer room. Fire Saf Sci-Proceeding of the Eighth International Symposium 2005:765–776CrossRef Han Y, Choi B, Kim M (2005) Application of a fixed water mist system in a power transformer room. Fire Saf Sci-Proceeding of the Eighth International Symposium 2005:765–776CrossRef
10.
go back to reference Liang P, Zhou T, Chen B et al (2021) Experimental study on the effectiveness of water mist containing surfactant on extinguishing transformer oil fire. In: The 5th IEEE conference on energy internet and energy system integration, pp 3698–3703 Liang P, Zhou T, Chen B et al (2021) Experimental study on the effectiveness of water mist containing surfactant on extinguishing transformer oil fire. In: The 5th IEEE conference on energy internet and energy system integration, pp 3698–3703
11.
go back to reference GB 50219-2014 (2014) Technical code for water spray fire protection systems. China Planning Press, Beijing GB 50219-2014 (2014) Technical code for water spray fire protection systems. China Planning Press, Beijing
12.
go back to reference GB 50898-2013 (2013) Technical code for water mist fire extinguishing system. China Planning Press, Beijing GB 50898-2013 (2013) Technical code for water mist fire extinguishing system. China Planning Press, Beijing
13.
go back to reference GB 50151-2010 (2013) Code of design for foam extinguishing systems. China Planning Press, Beijing GB 50151-2010 (2013) Code of design for foam extinguishing systems. China Planning Press, Beijing
14.
go back to reference GB 50338-2003 (2003) Code of design for fixed fire monitor extinguishing systems. China Planning Press, Beijing GB 50338-2003 (2003) Code of design for fixed fire monitor extinguishing systems. China Planning Press, Beijing
15.
go back to reference Yilmaz F, Zengin M, Cure C (2020) Determination of ecologically sensitive areas in Denizli province using geographic information systems (GIS) and analytical hierarchy process (AHP). Environ Monit Assess 192(9):1–13CrossRef Yilmaz F, Zengin M, Cure C (2020) Determination of ecologically sensitive areas in Denizli province using geographic information systems (GIS) and analytical hierarchy process (AHP). Environ Monit Assess 192(9):1–13CrossRef
16.
go back to reference Ozturk N, Karacan I, Tozan H et al (2017) Defining criteria weights by AHP in health technology assessment. Value Health 20(9):698CrossRef Ozturk N, Karacan I, Tozan H et al (2017) Defining criteria weights by AHP in health technology assessment. Value Health 20(9):698CrossRef
17.
go back to reference Liu R, Cheng W, Yu Y et al (2018) Human factors analysis of major coal mine accidents in China based on the HFACS-CM model and AHP method. Int J Ind Ergon 68:270–279CrossRef Liu R, Cheng W, Yu Y et al (2018) Human factors analysis of major coal mine accidents in China based on the HFACS-CM model and AHP method. Int J Ind Ergon 68:270–279CrossRef
18.
go back to reference Dalal J, Mohapatra P, Mitra G (2010) Prioritization of rural roads: AHP in group decision. Eng Constr Archit Manage 17(2):135–158CrossRef Dalal J, Mohapatra P, Mitra G (2010) Prioritization of rural roads: AHP in group decision. Eng Constr Archit Manage 17(2):135–158CrossRef
19.
go back to reference Hunag Z (2020) Research on the optimal selection of 110kV substation comprehensive automation reconstruction scheme based on analytic hierarchy process. Master Thesis, China, Jilin University. (In Chinese) Hunag Z (2020) Research on the optimal selection of 110kV substation comprehensive automation reconstruction scheme based on analytic hierarchy process. Master Thesis, China, Jilin University. (In Chinese)
20.
go back to reference Bhattacharya G, Ghosh K, Chowdhury A (2017) Granger causality driven AHP for feature weighted kNN. Pattern Recogn 66:425–436CrossRef Bhattacharya G, Ghosh K, Chowdhury A (2017) Granger causality driven AHP for feature weighted kNN. Pattern Recogn 66:425–436CrossRef
22.
go back to reference Chen J (2019) Fault prediction of a transformer bushing based on entropy weight TOPSIS and gray theory. Comput Sci Eng 21(6):55–62CrossRef Chen J (2019) Fault prediction of a transformer bushing based on entropy weight TOPSIS and gray theory. Comput Sci Eng 21(6):55–62CrossRef
23.
go back to reference Li T, Wang Q (2012) Scheme evaluation of general layout design based on entropy weight and improved analytic hierarchy process method. J Lanzhou Univ Technol 38(2):120–123 (In Chinese) Li T, Wang Q (2012) Scheme evaluation of general layout design based on entropy weight and improved analytic hierarchy process method. J Lanzhou Univ Technol 38(2):120–123 (In Chinese)
Metadata
Title
Effectiveness Test and Evaluation of Transformer Fire Extinguishing System
Authors
Yu Liu
Bo Li
Chuanping Wu
Baohui Chen
Bichen Pan
Publication date
03-08-2022
Publisher
Springer US
Published in
Fire Technology / Issue 5/2022
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-022-01297-0

Other articles of this Issue 5/2022

Fire Technology 5/2022 Go to the issue