Abstract

The aim of the study was to examine the influence of the state of the pulp and apical periodontium on the results of electronic root canal length measurement (ERCLM) with a resistance measuring device in dogs. Pulpitis and apical periodontitis were induced by pulp exposure and contamination by the oral flora in the premolar teeth of six mongrel dogs, comprising four experimental groups (36 root canals). In a control group, measured lengths of teeth with uninfected pulps were performed on the first experimental day (44 root canals). In all animals the ERCLMs were performed on teeth with healthy pulps, and at the end of the experimental period (20, 35, 50 and 65 days) following pulp exposure. The point of measuring canal lengths was the anatomical obstacle above the apical delta. Electronically measured lengths (EML) were compared between each other and with the root canal length established by tactile-sense measurement verified radiographically. The EMLs were less accurate in teeth with healthy pulps and teeth with pulpitis in the third experimental group (dif = 2.27 × 2.65 mm2; t test, p < 0.05), while they were most precise after 65 days in teeth with completely necrotic pulp and established chronic apical periodontitis (dif = 0.54 × 1.36 mm2; t test, p > 0.05). These results suggest that the state of the pulp and periapical tissue may have an influence on the ERCLM.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Abbott PV (1987) Clinical evaluation of an electronic root canal measuring device. Aust Dent J 32:17–21CrossRef Abbott PV (1987) Clinical evaluation of an electronic root canal measuring device. Aust Dent J 32:17–21CrossRef
2.
go back to reference Burns DH, Mc Donald SGG (1975) Ionska vodljivost. In: Burns DH, Mc Donald SGG (eds) Fizika za biologe i medicinare. Školska knjiga, Zagreb, pp 336–385 Burns DH, Mc Donald SGG (1975) Ionska vodljivost. In: Burns DH, Mc Donald SGG (eds) Fizika za biologe i medicinare. Školska knjiga, Zagreb, pp 336–385
3.
go back to reference Dunlap CA, Remeikis NA, Begole EA, Rauschenberger CR (1998) An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endodon 24:48–50CrossRef Dunlap CA, Remeikis NA, Begole EA, Rauschenberger CR (1998) An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endodon 24:48–50CrossRef
4.
go back to reference Huang L (1987) An experimental study of the principle of electronic root canal measurement. J Endodon 13:60–64CrossRef Huang L (1987) An experimental study of the principle of electronic root canal measurement. J Endodon 13:60–64CrossRef
5.
go back to reference Ingle JI, Himel Van T, Hawrish CE, Glickman GN, Serene T, Rosenberg PA, Buchanan LS, West JD, Ruddle CJ, Camp JH, Roane JB, Cecchini SCM (2002) Endodontic cavity preparation. In: Ingle JI, Bakland LK (eds) Endodontics. BC Decker Inc, London, pp 405–570 Ingle JI, Himel Van T, Hawrish CE, Glickman GN, Serene T, Rosenberg PA, Buchanan LS, West JD, Ruddle CJ, Camp JH, Roane JB, Cecchini SCM (2002) Endodontic cavity preparation. In: Ingle JI, Bakland LK (eds) Endodontics. BC Decker Inc, London, pp 405–570
6.
go back to reference Kaufman AY, Keila S, Yoshpe M (2002) Accuracy of a new apex locator: an in vitro study. Int Endod J 35:186–192CrossRef Kaufman AY, Keila S, Yoshpe M (2002) Accuracy of a new apex locator: an in vitro study. Int Endod J 35:186–192CrossRef
7.
go back to reference Kovačević M, Tamarut T (1998) Influence of the concentration of ions and foramen diameter on the accuracy of the electronic root canal length measurement—an experimental study. J Endodon 24:346–351CrossRef Kovačević M, Tamarut T (1998) Influence of the concentration of ions and foramen diameter on the accuracy of the electronic root canal length measurement—an experimental study. J Endodon 24:346–351CrossRef
8.
go back to reference Lee SJ, Nam KC, Kim YJ, Kim DW (2002) Clinical accuracy of a new apex locator with and automatic compensation circuit. J Endodon 28:706–709CrossRef Lee SJ, Nam KC, Kim YJ, Kim DW (2002) Clinical accuracy of a new apex locator with and automatic compensation circuit. J Endodon 28:706–709CrossRef
9.
go back to reference Meredith N, Gulabivala K (1997) Electrical impedance measurements of root canal length. Endod Dent Traumatol 13:126–131CrossRef Meredith N, Gulabivala K (1997) Electrical impedance measurements of root canal length. Endod Dent Traumatol 13:126–131CrossRef
10.
go back to reference O’Neill LJ (1973) A clinical evaluation of electronic root canal measurement. Oral Surg 38:469–473CrossRef O’Neill LJ (1973) A clinical evaluation of electronic root canal measurement. Oral Surg 38:469–473CrossRef
11.
go back to reference Pahncke D, Voss A (1991) Die Abhängigkeit endometrischer Messungen von den Bedinungen im Wurzelkanal. Dtsch Zahnärztl 46:35–36 Pahncke D, Voss A (1991) Die Abhängigkeit endometrischer Messungen von den Bedinungen im Wurzelkanal. Dtsch Zahnärztl 46:35–36
12.
go back to reference Shabahang S,Goon WWY, Gluskin AH (1996) An in vivo evaluation of Root ZX electronic apex locator. J Endodon 22:616–618CrossRef Shabahang S,Goon WWY, Gluskin AH (1996) An in vivo evaluation of Root ZX electronic apex locator. J Endodon 22:616–618CrossRef
13.
go back to reference Stein TJ,Corcoran JF, Zillich RM (1990) The influence of the major and minor foramen diameters on apical electronic probe measurements. J Endodon 16:520–522CrossRef Stein TJ,Corcoran JF, Zillich RM (1990) The influence of the major and minor foramen diameters on apical electronic probe measurements. J Endodon 16:520–522CrossRef
14.
15.
go back to reference Sunada I (1962) New method for measuring the length of the root canal. J Dent Res 41:375–387 Sunada I (1962) New method for measuring the length of the root canal. J Dent Res 41:375–387
16.
go back to reference Tamarut T,Cindrić N, Međugorac G (1988) Qualitative changes of the pulp and multiple electric measurement of the canal. Acta Stomatol Croat 22:45–53 Tamarut T,Cindrić N, Međugorac G (1988) Qualitative changes of the pulp and multiple electric measurement of the canal. Acta Stomatol Croat 22:45–53
17.
go back to reference Tamarut T,Cindrić N, Međugorac B, Bertović G (1989) Relationship between ions concentrations: Na+, K+, Ca++, Mg++ and the bioelectrical properties of human dental pulp. Medicina 25:91–97 Tamarut T,Cindrić N, Međugorac B, Bertović G (1989) Relationship between ions concentrations: Na+, K+, Ca++, Mg++ and the bioelectrical properties of human dental pulp. Medicina 25:91–97
18.
go back to reference Tamarut T, Cindrić N, Blašković V, Maričić B (1990) Relationship between alkali metal concentration and electrical properties of human dental pulp. Int Endod J 23:63 Tamarut T, Cindrić N, Blašković V, Maričić B (1990) Relationship between alkali metal concentration and electrical properties of human dental pulp. Int Endod J 23:63
19.
go back to reference Tamarut T, Kovačević M, Uhač I (2000) Detection of a transitional ion concentration zone during electronic measurement of root canal length—a study in vitro. Int Endod J 33:374–380CrossRef Tamarut T, Kovačević M, Uhač I (2000) Detection of a transitional ion concentration zone during electronic measurement of root canal length—a study in vitro. Int Endod J 33:374–380CrossRef
20.
go back to reference Tamarut T, Kovačević M, Glavičić S (2006) Influence of the length of instrumentation and canal obturation on the success of endodontic therapy. A ten year clinical follow-up. Am J Dent (in press) Tamarut T, Kovačević M, Glavičić S (2006) Influence of the length of instrumentation and canal obturation on the success of endodontic therapy. A ten year clinical follow-up. Am J Dent (in press)
21.
go back to reference Thomas AS, Hartwell GR, Moon PC (2003) The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files. J Endod 29:662–663CrossRef Thomas AS, Hartwell GR, Moon PC (2003) The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files. J Endod 29:662–663CrossRef
22.
go back to reference Wu JN, Shi JN, Juang LZ, Xu YY (1992) Variables affecting electronic root canal measurement. Int Endod J 25:88–92CrossRef Wu JN, Shi JN, Juang LZ, Xu YY (1992) Variables affecting electronic root canal measurement. Int Endod J 25:88–92CrossRef
Metadata
Title
Electronic root canal length measurement before and after experimentally induced pulpitis and apical periodontitis in dogs
Authors
Maja Kovacevic
Tomislav Tamarut
Snježana Glavičić
Nives Jonjic
Sanja Zoričić-Cvek
Dragica Bobinac
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
Medical & Biological Engineering & Computing / Issue 8/2006
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-006-0076-7

Other articles of this Issue 8/2006

Medical & Biological Engineering & Computing 8/2006 Go to the issue

Premium Partner