Evaluation of Left Ventricular Ejection Fraction Obtained from 201Tl Myocardial Perfusion Scan by CZT Cardiac Camera

Authors : Hsiao-Ling Chiang, Chien-Hsin Ting, Cheng-Pe Chang, Bang-Hung Yang, Jyh-Shyan Leu, Chi-Long Juang, Wen-Sheng Huang

Published in: Future Trends in Biomedical and Health Informatics and Cybersecurity in Medical Devices

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Taking advantage of high energy and spatial resolution and high count sensitivity, the ultrafast cardiac γ-camera with cadmium-zinc-telluride (CZT)-based detectors has become popular in practice for myocardial perfusion imaging (MPI). The shorter imaging time with better imaging quality using CZT detectors compared to conventional ones makes it feasible to perform the left ventricular ejection fraction (LVEF) in the meantime of doing 201Tl MPI. The aim of this study was to compare LVEF from 201Tl MPI using a CZT with that from first-pass radionuclide angiography (FPRA) using a NaI camera.
A total of 117 patients (aged 81 ± 13 years old) were collected. All underwent 201Tl MPI using a CZT camera (Discovery NM530c) and FPRA using a conventional camera (Symbia E Signal Head System) in 2 wks. Correlations of LVEF obtained from these two examinations were evaluated by SPSS 20.0 statistical software.
Our results showed that the mean LVEF measured from MPI and FPRA were 54 ± 18% and 51 ± 16%, respectively. A good linear correlation was found between both methods (r: 0.861, p < 0.0001). It also showed a good agreement and LVEF prediction rates (k = 0.83) obtained from these two measurements. Tl-201 MPI with CZT camera is thus capable to offer a reliable clinical LVEF references.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Gambhir, S.S., Berman, D.S., Ziffer, J., Nagler, M., et al.: A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J. Nucl. Med. 50, 635–643 (2009)CrossRef Gambhir, S.S., Berman, D.S., Ziffer, J., Nagler, M., et al.: A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J. Nucl. Med. 50, 635–643 (2009)CrossRef
2.
go back to reference Ben-Haim, S., Kennedy, J., Keidar, Z.: Novel cadmium zinc telluride devices for myocardial perfusion imaging-technological aspects and clinical applications. Semin. Nucl. Med. 46, 273–285 (2016)CrossRef Ben-Haim, S., Kennedy, J., Keidar, Z.: Novel cadmium zinc telluride devices for myocardial perfusion imaging-technological aspects and clinical applications. Semin. Nucl. Med. 46, 273–285 (2016)CrossRef
3.
go back to reference Lugomirski, P., Chow, B., Ruddy, T.: Impact of SPECT myocardial perfusion imaging on cardiac care. Expert Rev. Cardiovasc. Ther. 12, 1247–1249 (2014)CrossRef Lugomirski, P., Chow, B., Ruddy, T.: Impact of SPECT myocardial perfusion imaging on cardiac care. Expert Rev. Cardiovasc. Ther. 12, 1247–1249 (2014)CrossRef
4.
go back to reference Songy, B., Lussato, D., Guernou, M., Queneau, M., Geronazzo, R.: Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium-zinc-telluride cardiac camera and a conventional SPECT camera. Clin. Nucl. Med. 36, 776–780 (2011)CrossRef Songy, B., Lussato, D., Guernou, M., Queneau, M., Geronazzo, R.: Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium-zinc-telluride cardiac camera and a conventional SPECT camera. Clin. Nucl. Med. 36, 776–780 (2011)CrossRef
5.
go back to reference Mouden, M., Timmer, J.R., Ottervanger, J.P., et al.: Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose. Eur. J. Nucl. Med. Mol. Imaging 39, 1048–1055 (2012)CrossRef Mouden, M., Timmer, J.R., Ottervanger, J.P., et al.: Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose. Eur. J. Nucl. Med. Mol. Imaging 39, 1048–1055 (2012)CrossRef
6.
go back to reference Songy, B., Guernou, M., Lussato, D., et al.: Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera. Nucl. Med. Commun. 33, 464–469 (2012)CrossRef Songy, B., Guernou, M., Lussato, D., et al.: Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera. Nucl. Med. Commun. 33, 464–469 (2012)CrossRef
7.
go back to reference Duvall, W., Croft, L., Ginsberg, E., et al.: Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera. J. Nucl. Cardiol. 18, 847–857 (2011)CrossRef Duvall, W., Croft, L., Ginsberg, E., et al.: Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera. J. Nucl. Cardiol. 18, 847–857 (2011)CrossRef
8.
go back to reference Kliner, D., Wang, L., Winger, D., et al.: A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT. J. Nucl. Cardiol. 22, 1237–1243 (2015)CrossRef Kliner, D., Wang, L., Winger, D., et al.: A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT. J. Nucl. Cardiol. 22, 1237–1243 (2015)CrossRef
9.
go back to reference Ishihara, M., Taniguchi, Y., Onoguchi, M., et al.: Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imaging. J. Nucl. Cardiol. 25, 947–954 (2018)CrossRef Ishihara, M., Taniguchi, Y., Onoguchi, M., et al.: Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imaging. J. Nucl. Cardiol. 25, 947–954 (2018)CrossRef
10.
go back to reference Gerard, J., Bryan, D.: Principles of Anatomy and Physiology. Wiley, Hoboken (2011) Gerard, J., Bryan, D.: Principles of Anatomy and Physiology. Wiley, Hoboken (2011)
11.
go back to reference Kincl, V., Kamínek, M., Vašina, J.D., et al.: Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera. Int. J. Cardiovasc. Imaging 32, 1463–1469 (2016)CrossRef Kincl, V., Kamínek, M., Vašina, J.D., et al.: Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera. Int. J. Cardiovasc. Imaging 32, 1463–1469 (2016)CrossRef
12.
go back to reference De Lorenzo, A., Peclat, T., Amaral, A.D., et al.: Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera. Int. J. Cardiovasc. Imaging 32, 355–361 (2016)CrossRef De Lorenzo, A., Peclat, T., Amaral, A.D., et al.: Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera. Int. J. Cardiovasc. Imaging 32, 355–361 (2016)CrossRef
13.
go back to reference Mettler Jr., F.A., Guiberteau, M.J.: Essentials of Nuclear Medicine Imaging, 4th edn. Saunders, Philadelphia (1998) Mettler Jr., F.A., Guiberteau, M.J.: Essentials of Nuclear Medicine Imaging, 4th edn. Saunders, Philadelphia (1998)
14.
go back to reference Depuey, G., Rozanski, A.: Using gated technetium-99msestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J. Nucl. Med. 36, 952–955 (1995) Depuey, G., Rozanski, A.: Using gated technetium-99msestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J. Nucl. Med. 36, 952–955 (1995)
15.
go back to reference Steven, B., Anita, M.D.: Artifacts and pitfalls in myocardial perfusion imaging. J. Nucl. Med. 34, 193–211 (2006) Steven, B., Anita, M.D.: Artifacts and pitfalls in myocardial perfusion imaging. J. Nucl. Med. 34, 193–211 (2006)
Metadata
Title
Evaluation of Left Ventricular Ejection Fraction Obtained from 201Tl Myocardial Perfusion Scan by CZT Cardiac Camera
Authors
Hsiao-Ling Chiang
Chien-Hsin Ting
Cheng-Pe Chang
Bang-Hung Yang
Jyh-Shyan Leu
Chi-Long Juang
Wen-Sheng Huang
Copyright Year
2020
DOI
https://doi.org/10.1007/978-3-030-30636-6_43