Abstract

This paper reports the experimental results obtained from the first phase of the study involving the loading tests for reinforced concrete (RC) beams retrofitted with the jacketing ferrocement system. Five beams, in which one is the control beam, and the other four beams are enlarged with ferrocement jacket, are prepared for the four-point bending tests. The obtained results indicate that the retrofit of the RC beams with ferrocement jacket alone induces the adverse influence on the member performance in terms of the load-carrying capacity, stiffness, safety, and ductility. In contrast, the strengthening with the ferrocement jacket incorporating addition of the steel tension bars noticeably improves the flexural efficiency of the RC beams. In such circumstance, besides the amelioration in the capacity, stiffness, and ductility, the strengthened beams exhibit numerous flexural cracks with narrow spacing and small width following the yielding of longitudinal reinforcement and the crushing of concrete at loading area. In addition, the continuity for the stress transfer at the ferrocement–concrete bonded interface remarkably governs the failure mechanism and ductility of the retrofitted beams. The discontinuity of the adherence between ferrocement and concrete by shear connector with anchored bars coupling the addition of the tensile reinforcement positively impacts the performance of the ferrocement-retrofitted beams. Sectional analysis cannot predict the flexural strength of the beams retrofitted with only ferrocement, while it can accurately assess the maximum capacity of the control beam and the beams with both ferrocement jacket and additional steels.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference ACI Committee 549–1R-88 (1993) Guide for design construction and repair of ferrocement. ACI 549–1R-88 and 1R-93 manual of concrete practice, Detroit ACI Committee 549–1R-88 (1993) Guide for design construction and repair of ferrocement. ACI 549–1R-88 and 1R-93 manual of concrete practice, Detroit
2.
go back to reference ACI Committee 549 (1997) State of the art report on ferrocement. ACI 549-R97 manual of concrete practice, Detroit ACI Committee 549 (1997) State of the art report on ferrocement. ACI 549-R97 manual of concrete practice, Detroit
3.
go back to reference ACI (American Concrete Institute) (2019) Building code requirements for structural concrete and commentary. ACI 318–19. Detroit: ACI ACI (American Concrete Institute) (2019) Building code requirements for structural concrete and commentary. ACI 318–19. Detroit: ACI
23.
go back to reference Golias E, Zapris AG, Kytinou VK, Osman M, Koumtzis M, Siapera D, Chalioris CE, Karayannis CG (2021) Application of X-shaped cfrp ropes for structural upgrading of reinforced concrete beam–column joints under cyclic loading–experimental study. Fibers. https://doi.org/10.3390/fib9070042CrossRef Golias E, Zapris AG, Kytinou VK, Osman M, Koumtzis M, Siapera D, Chalioris CE, Karayannis CG (2021) Application of X-shaped cfrp ropes for structural upgrading of reinforced concrete beam–column joints under cyclic loading–experimental study. Fibers. https://​doi.​org/​10.​3390/​fib9070042CrossRef
26.
go back to reference Heiza K, Nabil A, Nageh M, Magdy T (2014) State-of-the art review: Strengthening of reinforced concrete structures–different strengthening techniques, In: Sixth international conference on nano-technology in construction, 22–24. Heiza K, Nabil A, Nageh M, Magdy T (2014) State-of-the art review: Strengthening of reinforced concrete structures–different strengthening techniques, In: Sixth international conference on nano-technology in construction, 22–24.
30.
go back to reference Kaish ABMA, Jamil M, Raman SN, Zain MFM (2015) Axial behavior of ferrocement confined cylindrical concrete specimens with different sizes. Constr Build Mater 78:50–59CrossRef Kaish ABMA, Jamil M, Raman SN, Zain MFM (2015) Axial behavior of ferrocement confined cylindrical concrete specimens with different sizes. Constr Build Mater 78:50–59CrossRef
39.
go back to reference Lenwari A, ThongchomC, Aboutaha RS (2020) Cyclic flexural performance of fire-damaged reinforced concrete beams strengthened with carbon fiber-reinforced polymer plates, ACI Struct J. Lenwari A, ThongchomC, Aboutaha RS (2020) Cyclic flexural performance of fire-damaged reinforced concrete beams strengthened with carbon fiber-reinforced polymer plates, ACI Struct J.
Metadata
Title
Experimental analysis on reinforced concrete beams enlarged with ferrocement retrofit system
Authors
Linh Van Hong Bui
Supawit Saiwimarn
Sayan Sirimontree
Chanachai Thongchom
Suraparb Keawsawasvong
Phuoc Trong Nguyen
Yen Thi Hai Nguyen
Jintara Lawongkerd
Chayut Ngamkhanong
Thanh-Truong Nguyen
Publication date
01-12-2022
Publisher
Springer International Publishing
Published in
Innovative Infrastructure Solutions / Issue 6/2022
Print ISSN: 2364-4176
Electronic ISSN: 2364-4184
DOI
https://doi.org/10.1007/s41062-022-00935-4

Other articles of this Issue 6/2022

Innovative Infrastructure Solutions 6/2022 Go to the issue