Experimental Investigation of the Effect of Fire Protection Lobby on Stair Pressurization System in a High-Rise Building

Authors: Busra Hepguzel Acikyol, Gokhan Balik, Abdurrahman Kilic

Published in: Fire Technology | Issue 1/2017

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In this study, the stair pressurization system in a 40-storey high office building in Istanbul is investigated through field tests, in order to understand the effect of the presence of a non-pressurized vestibule (fire protection lobby, FPL) before entering the stair at each floor. The building without FPL is simulated by keeping only one of the two doors (of the stair and FPL) open at each floor. This method gave an opportunity to fix other parameters affecting the stair pressurization system and check solely the effect of FPL. Two different cases are taken into account, where the first one (all doors closed) analyses the condition that all stair doors are kept closed and the second one (critical doors are open) is conducted when the stairwell is opened to the floor on a given level (fire floor) and the stair termination door at the discharge floor is kept open. For both cases, the availability of the FPL is investigated by using the aforementioned arrangement. Under the conditions with approximately the same pressurized air flow rate at all doors closed condition, it is found that the availability of FPL increases the pressure difference between the stairwell and the corridor by a factor of approximately 2.2. This is also justified by using empirical formulations available in literature, where this ratio is calculated as 2.0. The results of this study showed that the FPL arrangement improves the effectiveness of pressurization system in a very high-rise building, despite some tolerable drawbacks.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Wang Y, Gao F (2004) Tests of stairwell pressurization systems for smoke control in a high-rise building. ASHRAE Trans, 110:185–193 Wang Y, Gao F (2004) Tests of stairwell pressurization systems for smoke control in a high-rise building. ASHRAE Trans, 110:185–193
2.
go back to reference Chung KC (1999) Evaluation of smoke exhaustion performance of a vestibule within tall buildings in Taiwan. Int J Eng Perform Based Fire Codes, 1:71–80 Chung KC (1999) Evaluation of smoke exhaustion performance of a vestibule within tall buildings in Taiwan. Int J Eng Perform Based Fire Codes, 1:71–80
3.
go back to reference Kim JY, Shin HJ, Ahn CS, Kim JS, Joo SH (2014) Development of the separate air-supply type of pressurization smoke control system for the stairwells of high-rise buildings in Korea. Open J Fluid Dyn 4:251–262. doi:10.4236/ojfd.2014.43019 CrossRef Kim JY, Shin HJ, Ahn CS, Kim JS, Joo SH (2014) Development of the separate air-supply type of pressurization smoke control system for the stairwells of high-rise buildings in Korea. Open J Fluid Dyn 4:251–262. doi:10.​4236/​ojfd.​2014.​43019 CrossRef
4.
go back to reference NFPA (2012) NFPA 92® Standard for smoke control systems. National Fire Protection Association, Massachusetts NFPA (2012) NFPA 92® Standard for smoke control systems. National Fire Protection Association, Massachusetts
5.
go back to reference BSI (2005) BS EN 12101-6:2005 Smoke and heat control systems—Part 6: specification for pressure differential systems—Kits. CEN, Brussels BSI (2005) BS EN 12101-6:2005 Smoke and heat control systems—Part 6: specification for pressure differential systems—Kits. CEN, Brussels
6.
go back to reference BSI (1998) BS 5588-4:1998 Fire precautions in the design, construction and use of buildings—Part 4: code of practice for smoke control using pressure differentials. BSI BSI (1998) BS 5588-4:1998 Fire precautions in the design, construction and use of buildings—Part 4: code of practice for smoke control using pressure differentials. BSI
7.
go back to reference TÜYAK (2012). Turkey’s regulation on fire protection regulation on fire protection of buildings. Turkish Fire Protection and Education Foundation, Istanbul TÜYAK (2012). Turkey’s regulation on fire protection regulation on fire protection of buildings. Turkish Fire Protection and Education Foundation, Istanbul
8.
go back to reference De Cicco PR, Cresci RJ, Correale WH (1972) Report of fire tests, analyses and evaluation of stair pressurization and exhaust in high-rise office buildings. Polytechnic Institute of Brooklyn Center for Urban Environmental Studies, Baywood Publishing Company De Cicco PR, Cresci RJ, Correale WH (1972) Report of fire tests, analyses and evaluation of stair pressurization and exhaust in high-rise office buildings. Polytechnic Institute of Brooklyn Center for Urban Environmental Studies, Baywood Publishing Company
9.
go back to reference Shaw CY, Tamura GT (1976) Design of a stairshaft pressurization system for tall buildings. ASHRAE J 18(2):29–33 Shaw CY, Tamura GT (1976) Design of a stairshaft pressurization system for tall buildings. ASHRAE J 18(2):29–33
10.
go back to reference Tamura GT (1989) Stair pressurization systems for smoke control: design considerations. ASHRAE Trans 95(2):184–192 Tamura GT (1989) Stair pressurization systems for smoke control: design considerations. ASHRAE Trans 95(2):184–192
11.
go back to reference Tamura GT (1991) Determination of critical air velocities to prevent smoke backflow at a star door opening on the fire floor. ASHRAE Trans 97(2):627–633 Tamura GT (1991) Determination of critical air velocities to prevent smoke backflow at a star door opening on the fire floor. ASHRAE Trans 97(2):627–633
12.
go back to reference Tamura GT (1974) Experimental studies on pressurized escape routes. ASHRAE Trans 80(2):224–237 Tamura GT (1974) Experimental studies on pressurized escape routes. ASHRAE Trans 80(2):224–237
13.
go back to reference Tamura GT, Shaw CY (1976) Air leakage data for the design of elevator and stair shaft pressurization systems. ASHRAE Trans 82(2):179–190 Tamura GT, Shaw CY (1976) Air leakage data for the design of elevator and stair shaft pressurization systems. ASHRAE Trans 82(2):179–190
14.
go back to reference Tamura GT, Shaw CY (1978) Experimental studies of mechanical venting for smoke control in tall office buildings. ASHRAE Trans 84(1):54–71 Tamura GT, Shaw CY (1978) Experimental studies of mechanical venting for smoke control in tall office buildings. ASHRAE Trans 84(1):54–71
15.
go back to reference Tamura GT, Shaw CY (1976) Studies on exterior wall air tightness and air infiltration of tall buildings. ASHRAE Trans 82(1):122–134 Tamura GT, Shaw CY (1976) Studies on exterior wall air tightness and air infiltration of tall buildings. ASHRAE Trans 82(1):122–134
16.
go back to reference Shaw CY, Reardon JT, Cheung MS (1993) Changes in air leakage levels of six Canadian office buildings. ASHRAE J 35(2):34–36 Shaw CY, Reardon JT, Cheung MS (1993) Changes in air leakage levels of six Canadian office buildings. ASHRAE J 35(2):34–36
17.
go back to reference Tamura GT (1990) Fire tower tests of stair pressurization systems with overpressure relief. ASHRAE Trans 96(2):373–383 Tamura GT (1990) Fire tower tests of stair pressurization systems with overpressure relief. ASHRAE Trans 96(2):373–383
18.
go back to reference Tamura GT (1990) Field tests of stair pressurization systems with overpressure relief. ASHRAE Trans 96(1):951–958 Tamura GT (1990) Field tests of stair pressurization systems with overpressure relief. ASHRAE Trans 96(1):951–958
19.
go back to reference Chow W, Lam LW (1993) 3710 evaluation of a staircase pressurization system. ASHRAE Trans 99(2):194–199 Chow W, Lam LW (1993) 3710 evaluation of a staircase pressurization system. ASHRAE Trans 99(2):194–199
20.
go back to reference [20] Bellido C, Quiroz A, Panizo A, Torero JL (2009). Performance assessment of pressurized stairs in high rise buildings. Fire technology 45(2):189–200CrossRef [20] Bellido C, Quiroz A, Panizo A, Torero JL (2009). Performance assessment of pressurized stairs in high rise buildings. Fire technology 45(2):189–200CrossRef
21.
go back to reference Tamura GT (1994) Fire tower tests on vestibule pressurization for protection of stairshafts. ASHRAE Trans 100(1):981–989 Tamura GT (1994) Fire tower tests on vestibule pressurization for protection of stairshafts. ASHRAE Trans 100(1):981–989
22.
go back to reference Kujime M, Matsushita T, Tanaka T (1999) Hand calculation method for air supply rates in vestibule pressurization smoke control system. Int J Eng Perform Based Fire Codes 1(1):27–40 Kujime M, Matsushita T, Tanaka T (1999) Hand calculation method for air supply rates in vestibule pressurization smoke control system. Int J Eng Perform Based Fire Codes 1(1):27–40
23.
go back to reference Klote JH, Milke JA (2002) Principles of Smoke Management. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta Klote JH, Milke JA (2002) Principles of Smoke Management. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta
24.
go back to reference Hobson PJ, Stewart LJ (1972) Pressurization of escape routes in buildings. Fire Research Notes 958. Heating, Ventilating Research Association Hobson PJ, Stewart LJ (1972) Pressurization of escape routes in buildings. Fire Research Notes 958. Heating, Ventilating Research Association
Metadata
Title
Experimental Investigation of the Effect of Fire Protection Lobby on Stair Pressurization System in a High-Rise Building
Authors
Busra Hepguzel Acikyol
Gokhan Balik
Abdurrahman Kilic
Publication date
18-01-2016
Publisher
Springer US
Published in
Fire Technology / Issue 1/2017
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-015-0560-4

Other articles of this Issue 1/2017

Fire Technology 1/2017 Go to the issue