Skip to main content
Top
Published in: Electrical Engineering 2/2016

10-12-2015 | Original Paper

Fault detection and fault-tolerant control of power converter fed PMSM

Authors: Mongi Moujahed, Hechmi Ben Azza, Khaled Frifita, Mohamed Jemli, Mohamed Boussak

Published in: Electrical Engineering | Issue 2/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In this paper, an investigation of inverter fault-tolerant field-oriented control for permanent magnet synchronous motor (PMSM) with loss of one transistor or loss of one phase is presented. The basic idea of this design consists in incorporating a fourth legs inverter, with the same topology of the three legs. In this case of fault-tolerant inverter, a redundant leg is added that replaces the faulted leg. The proposed inverter provides tolerance to open circuit fault of the switching devices. The detection of faulty legs is based only on the output inverter currents measurement. Experimental results show that the method is able to detect and isolate the open switch or the open phase faults in PMSM. In our case, the fault detection and isolation block is based on the current signals measured and the maximum threshold they exceed that in case of fault. The experimental implementation is carried out on powerful dSpace DS1103 controller board based on the digital signal processor.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Saidura R, Mekhilef S, Ali MB, Safari A, Mohammed HA (2012) Applications of variable speed drive (VSD) in electrical motors energy savings. Renew Sustain Energy Rev 16:543–550CrossRef Saidura R, Mekhilef S, Ali MB, Safari A, Mohammed HA (2012) Applications of variable speed drive (VSD) in electrical motors energy savings. Renew Sustain Energy Rev 16:543–550CrossRef
2.
go back to reference Boussak M (2005) Implementation and experimental investigation of sensorless speed control with initial rotor position estimation for interior permanent magnet synchronous motor drive. IEEE Trans Power Electron 20(6):1413–1421CrossRef Boussak M (2005) Implementation and experimental investigation of sensorless speed control with initial rotor position estimation for interior permanent magnet synchronous motor drive. IEEE Trans Power Electron 20(6):1413–1421CrossRef
3.
go back to reference Gulez K, Adam A, Buzcu İE, Pastac H (2007) Using passive filters to minimize torque pulsations and noises in surface PMSM derived field oriented control. Simul Model Pract Theory 15(8):989–1001CrossRef Gulez K, Adam A, Buzcu İE, Pastac H (2007) Using passive filters to minimize torque pulsations and noises in surface PMSM derived field oriented control. Simul Model Pract Theory 15(8):989–1001CrossRef
4.
go back to reference Maiti S, Chakraborty C, Sengupta S (2009) Simulation studies on model reference adaptive controller based speed estimation technique for the vector controlled permanent magnet synchronous motor drive. Simul Model Pract Theory 17(4):585–596CrossRef Maiti S, Chakraborty C, Sengupta S (2009) Simulation studies on model reference adaptive controller based speed estimation technique for the vector controlled permanent magnet synchronous motor drive. Simul Model Pract Theory 17(4):585–596CrossRef
5.
go back to reference Welchko BA, Jahns TM, Hiti S (2002) IPM synchronous machine drive response to a single-phase open circuit fault. IEEE Trans Power Electron 17(5):764–771CrossRef Welchko BA, Jahns TM, Hiti S (2002) IPM synchronous machine drive response to a single-phase open circuit fault. IEEE Trans Power Electron 17(5):764–771CrossRef
6.
go back to reference Bolognani S, Zordan M, Zigliotto M (2000) Experimental fault-tolerant control of a PMSM drive. IEEE Trans Ind Electron 47(5):1134–1141CrossRef Bolognani S, Zordan M, Zigliotto M (2000) Experimental fault-tolerant control of a PMSM drive. IEEE Trans Ind Electron 47(5):1134–1141CrossRef
7.
go back to reference Khan MASK, Rahman MA (2009) Development and implementation of a novel fault diagnostic and protection technique for IPM motor drives. IEEE Trans Ind Electron 56(1):85–92CrossRef Khan MASK, Rahman MA (2009) Development and implementation of a novel fault diagnostic and protection technique for IPM motor drives. IEEE Trans Ind Electron 56(1):85–92CrossRef
8.
go back to reference Azza HB, Jemli M, Boussak M, Gossa M (2011) High performance sensorless speed vector control of SPIM drives with on-line stator resistance estimation. Simul Model Pract Theory 19(1):271–282CrossRef Azza HB, Jemli M, Boussak M, Gossa M (2011) High performance sensorless speed vector control of SPIM drives with on-line stator resistance estimation. Simul Model Pract Theory 19(1):271–282CrossRef
9.
go back to reference Welchko BA, Lipo TA, Jahns TM, Schulz SE (2004) Fault tolerant three-phase AC motor drive topologies: a comparison of features, costs, and limitations. IEEE Trans Power Electron 19(4):1108–1116CrossRef Welchko BA, Lipo TA, Jahns TM, Schulz SE (2004) Fault tolerant three-phase AC motor drive topologies: a comparison of features, costs, and limitations. IEEE Trans Power Electron 19(4):1108–1116CrossRef
10.
go back to reference Riberio RLA, Jacobina CB, da Silva ERC, Lima AMN (2004) Fault-tolerant voltage-fed PWM inverter AC motor drive systems. IEEE Trans Ind Electron 51(2):439–446CrossRef Riberio RLA, Jacobina CB, da Silva ERC, Lima AMN (2004) Fault-tolerant voltage-fed PWM inverter AC motor drive systems. IEEE Trans Ind Electron 51(2):439–446CrossRef
11.
go back to reference Errabelli RR, Mutschler P (2012) Fault-tolerant voltage source inverter for permanent magnet drives. IEEE Trans Power Electron 27(2):500–508CrossRef Errabelli RR, Mutschler P (2012) Fault-tolerant voltage source inverter for permanent magnet drives. IEEE Trans Power Electron 27(2):500–508CrossRef
12.
go back to reference Choi C, Lee W (2012) Design and evaluation of voltage measurement-based sectoral diagnosis method for inverter open switch faults of permanent magnet synchronous motor drives. IET Electron Power Appl 6(8):526–532MathSciNetCrossRef Choi C, Lee W (2012) Design and evaluation of voltage measurement-based sectoral diagnosis method for inverter open switch faults of permanent magnet synchronous motor drives. IET Electron Power Appl 6(8):526–532MathSciNetCrossRef
13.
go back to reference Ribeiro RLDA, Jacobina CB, da Silva ERC, Lima AMN (2003) Fault detection of open-switch damage in voltage-fed PWM motor drive systems. IEEE Trans Power Electron 18(2):587–593CrossRef Ribeiro RLDA, Jacobina CB, da Silva ERC, Lima AMN (2003) Fault detection of open-switch damage in voltage-fed PWM motor drive systems. IEEE Trans Power Electron 18(2):587–593CrossRef
14.
go back to reference El-Refaie AM (2011) Fault-tolerant permanent magnet machines: a review. IET Electron Power Appl 5(1):59–74CrossRef El-Refaie AM (2011) Fault-tolerant permanent magnet machines: a review. IET Electron Power Appl 5(1):59–74CrossRef
15.
go back to reference Sun Z, Wang J, Howe D, Jewell G (2008) Analytical prediction of the short-circuit current in fault-tolerant permanent-magnet machines. IEEE Trans Ind Electron 55(12):4210–4217CrossRef Sun Z, Wang J, Howe D, Jewell G (2008) Analytical prediction of the short-circuit current in fault-tolerant permanent-magnet machines. IEEE Trans Ind Electron 55(12):4210–4217CrossRef
16.
go back to reference Liu W, Liu L, Chung I-Y, Cartes DA, Zhang Wei (2012) Modeling and detecting the stator winding fault of permanent magnet synchronous motors. Simul Model Pract Theory 27:1–16CrossRef Liu W, Liu L, Chung I-Y, Cartes DA, Zhang Wei (2012) Modeling and detecting the stator winding fault of permanent magnet synchronous motors. Simul Model Pract Theory 27:1–16CrossRef
17.
go back to reference Jha RK, Lingeswaran K (2013) Fault-tolerant voltage source inverter for permanent magnet synchronous motor. Int J Adv Res Electr Electron Instrum Eng 2(10):426–435 Jha RK, Lingeswaran K (2013) Fault-tolerant voltage source inverter for permanent magnet synchronous motor. Int J Adv Res Electr Electron Instrum Eng 2(10):426–435
Metadata
Title
Fault detection and fault-tolerant control of power converter fed PMSM
Authors
Mongi Moujahed
Hechmi Ben Azza
Khaled Frifita
Mohamed Jemli
Mohamed Boussak
Publication date
10-12-2015
Publisher
Springer Berlin Heidelberg
Published in
Electrical Engineering / Issue 2/2016
Print ISSN: 0948-7921
Electronic ISSN: 1432-0487
DOI
https://doi.org/10.1007/s00202-015-0350-5

Other articles of this Issue 2/2016

Electrical Engineering 2/2016 Go to the issue