Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry

Authors: K. Shafqat, D. P. Jones, R. M. Langford, P. A. Kyriacou

Published in: Medical & Biological Engineering & Computing | Issue 8/2006

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The oesophagus has been shown to be a reliable site for monitoring blood oxygen saturation (SpO2). However, the photoplethysmographic (PPG) signals from the lower oesophagus are frequently contaminated by a ventilator artefact making the estimation of SpO2 impossible. A 776th order finite impulse response (FIR) filter and a 695th order interpolated finite impulse response (IFIR) filter were implemented to suppress the artefact. Both filters attenuated the ventilator artefact satisfactorily without distorting the morphology of the PPG when processing recorded data from ten cardiopulmonary bypass patients. The IFIR filter was the better since it conformed more closely to the desired filter specifications and allowed real-time processing. The average improvements in signal-to-noise ratio (SNR) achieved by the FIR and IFIR filters for the fundamental component of the red PPG signals with respect to the fundamental component of the artefact were 57.96 and 60.60 dB, respectively. The corresponding average improvements achieved by the FIR and IFIR filters for the infrared PPG signals were 54.83 and 60.96 dB, respectively. Both filters were also compared with their equivalent tenth order Butterworth filters. The average SNR improvements for the FIR and IFIR filters were significantly higher than those for the Butterworth filters.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Freund PR, Overand PT, Cooper J, Jacobson L, Bosse S, Walker B, Posner KL, Cheney FW (1991) A prospective study of intraoperative pulse oximetry failure. J Clin Monit 7:253–258CrossRef Freund PR, Overand PT, Cooper J, Jacobson L, Bosse S, Walker B, Posner KL, Cheney FW (1991) A prospective study of intraoperative pulse oximetry failure. J Clin Monit 7:253–258CrossRef
3.
go back to reference Kyriacou PA, Powell S, Langford RM, Jones DP (2002) Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients. Physiol Meas 23:533–545CrossRef Kyriacou PA, Powell S, Langford RM, Jones DP (2002) Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients. Physiol Meas 23:533–545CrossRef
4.
go back to reference Kyriacou PA, Powell S, Jones DP, Langford RM (2003) Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery. Anaesthesia 58:422–427CrossRef Kyriacou PA, Powell S, Jones DP, Langford RM (2003) Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery. Anaesthesia 58:422–427CrossRef
5.
go back to reference Pal SK, Kyriacou PA, Kumaran S, Fadheel S, Emamdee R, Langford RM, Jones DP (2005) Evaluation of oesophageal reflectance pulse oximetry in major burns patients. Burns 31:337–341CrossRef Pal SK, Kyriacou PA, Kumaran S, Fadheel S, Emamdee R, Langford RM, Jones DP (2005) Evaluation of oesophageal reflectance pulse oximetry in major burns patients. Burns 31:337–341CrossRef
6.
go back to reference Palve H, Vuori A (1989) Pulse oximetry during low cardiac output and hypothermia states immediately after open heart surgery. Crit Care Med 17:66–69CrossRef Palve H, Vuori A (1989) Pulse oximetry during low cardiac output and hypothermia states immediately after open heart surgery. Crit Care Med 17:66–69CrossRef
7.
go back to reference Reich DL, Timcenko A, Bodian CA, Kraidin J, Hofman JB, Deperio M, Konstadt SN, Kurki T, Eisenkraft JB (1996) Predictors of pulse oximetry data failure. Anesthesiology 84:859–864CrossRef Reich DL, Timcenko A, Bodian CA, Kraidin J, Hofman JB, Deperio M, Konstadt SN, Kurki T, Eisenkraft JB (1996) Predictors of pulse oximetry data failure. Anesthesiology 84:859–864CrossRef
8.
go back to reference Saramäki T (1993) Handbook for digital signal processing. Wiley, New York, pp 155–279 Saramäki T (1993) Handbook for digital signal processing. Wiley, New York, pp 155–279
Metadata
Title
Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry
Authors
K. Shafqat
D. P. Jones
R. M. Langford
P. A. Kyriacou
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
Medical & Biological Engineering & Computing / Issue 8/2006
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-006-0089-2

Other articles of this Issue 8/2006

Medical & Biological Engineering & Computing 8/2006 Go to the issue

Premium Partner