Skip to main content
Top

2020 | OriginalPaper | Chapter

Finite Element Analysis and Theoretical Wear Behaviour for Total Hip Replacement

Authors : Shaik Akbar Basha, Debasish Sarkar

Published in: Emerging Trends in Mechanical Engineering

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In consideration of total hip replacement (THR) and theoretical life estimation, we extensively performed finite element analysis and predicted the wear behaviour of different head sizes of 28, 30 and 32 mm and two bearing systems namely ZTA head—ZTA liner and Ti6Al4V head—UHMWPE liner. Static but stance activity was encountered for the 100 kg subject, where the ZTA head—ZTA liner combination exhibit less von mises stress compared to Ti6Al4V head—UHMWPE liner bearing. Interestingly, 30 mm femoral head experiences more jump distance (JD) and more range of motion (ROM) in comparison of the 28 mm femoral head, and less deformation compares to 32 mm femoral head. The wear behaviour is estimated using Archard’s law and predicted wear depth is around 600 µm for 15 years for 30 mm femoral head during articulating motion with identical tribocouple.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Sariali E, Leonard P, Mamoudy P (2008) Dislocation after total hip arthroplasty using Hueter anterior approach. J Arthroplasty 23(2):266–272CrossRef Sariali E, Leonard P, Mamoudy P (2008) Dislocation after total hip arthroplasty using Hueter anterior approach. J Arthroplasty 23(2):266–272CrossRef
2.
go back to reference Alberton GM, High WA, Morrey BF (2002) Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg Am 84(10):1788–1792CrossRef Alberton GM, High WA, Morrey BF (2002) Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg Am 84(10):1788–1792CrossRef
3.
go back to reference Askari Ehsan, Flores Paulo, Dabirrahmani Danè, Appleyard Richard (2016) A review of squeaking in ceramic total hip prostheses. Tribol Int 93:239–256CrossRef Askari Ehsan, Flores Paulo, Dabirrahmani Danè, Appleyard Richard (2016) A review of squeaking in ceramic total hip prostheses. Tribol Int 93:239–256CrossRef
4.
go back to reference Bergmann G, Bender A, Dymke J, Duda G, Damm P (2016) Standardized loads acting in hip implants. PLoS ONE 11(5):e0155612CrossRef Bergmann G, Bender A, Dymke J, Duda G, Damm P (2016) Standardized loads acting in hip implants. PLoS ONE 11(5):e0155612CrossRef
5.
go back to reference Bergen H (2010) Annual Report 2010, Norwegian Arthroplasty Register. Norwegian Arthroplasty Register Bergen H (2010) Annual Report 2010, Norwegian Arthroplasty Register. Norwegian Arthroplasty Register
6.
go back to reference David D, Graves S, Tomkins A (2013) Anual Report 2013 Australien Orthopaedic Association National Joint Replacement Registry David D, Graves S, Tomkins A (2013) Anual Report 2013 Australien Orthopaedic Association National Joint Replacement Registry
7.
go back to reference Garellick G, Karrholm J, Rogmark C, Rolfson O, Herberts P (2011) Annual Report 2011. Swedish Hip Arthroplasty Register Garellick G, Karrholm J, Rogmark C, Rolfson O, Herberts P (2011) Annual Report 2011. Swedish Hip Arthroplasty Register
8.
go back to reference Tsouknidas Alexander, Anagnostidis Kleovoulos, Maliaris Georgios, Michailidis Nikolaos (2012) Fracture risk in the femoral hip region: a finite element analysis supported experimental approach. J Biomech 45:1959–1964CrossRef Tsouknidas Alexander, Anagnostidis Kleovoulos, Maliaris Georgios, Michailidis Nikolaos (2012) Fracture risk in the femoral hip region: a finite element analysis supported experimental approach. J Biomech 45:1959–1964CrossRef
9.
go back to reference Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN (2001) Hip contact forces and gait patterns from routine activities. J Biomech 34:639–642CrossRef Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN (2001) Hip contact forces and gait patterns from routine activities. J Biomech 34:639–642CrossRef
10.
go back to reference Fialho JC, Fernandes PR, Eca L, Folgado J (2007) Computational hip joint simulator for wear and heat generation. J Biomech 40:2358–2366CrossRef Fialho JC, Fernandes PR, Eca L, Folgado J (2007) Computational hip joint simulator for wear and heat generation. J Biomech 40:2358–2366CrossRef
11.
go back to reference Rancourt D, Shirazi-Adl A, Drouin G et al (1990) Friction properties of the interface between porous-surfaced metals and tibial cancellous bone. J Biomed Mater Res 24:1503–1519CrossRef Rancourt D, Shirazi-Adl A, Drouin G et al (1990) Friction properties of the interface between porous-surfaced metals and tibial cancellous bone. J Biomed Mater Res 24:1503–1519CrossRef
12.
go back to reference Khademhosseini A (2008) Micro and nanoengineering of the cell microenvironment: technologies and applications. Artech House Publishers Khademhosseini A (2008) Micro and nanoengineering of the cell microenvironment: technologies and applications. Artech House Publishers
13.
go back to reference Park J (2008) Bioceramics: properties, characterizations, and applications. Springer Park J (2008) Bioceramics: properties, characterizations, and applications. Springer
14.
go back to reference Wu JS, Hung J, Shu C, Chen J (2003) The computer simulation of wear behavior appearing in total hip prosthesis. Comput Methods Program Biomed 70:81–91CrossRef Wu JS, Hung J, Shu C, Chen J (2003) The computer simulation of wear behavior appearing in total hip prosthesis. Comput Methods Program Biomed 70:81–91CrossRef
15.
go back to reference Strey NF, Scandian C (2017) Tribological transitions during sliding of zirconia against alumina and ZTA in water. Wear 376–377:343–351CrossRef Strey NF, Scandian C (2017) Tribological transitions during sliding of zirconia against alumina and ZTA in water. Wear 376–377:343–351CrossRef
16.
go back to reference Shaik AB, Sarkar D (2019) Dynamic analysis and life estimation of the artificial hip joint prosthesis. In: Advances in Intelligent Systems and Computing, vol 949, Springer, pp 265–274 Shaik AB, Sarkar D (2019) Dynamic analysis and life estimation of the artificial hip joint prosthesis. In: Advances in Intelligent Systems and Computing, vol 949, Springer, pp 265–274
Metadata
Title
Finite Element Analysis and Theoretical Wear Behaviour for Total Hip Replacement
Authors
Shaik Akbar Basha
Debasish Sarkar
Copyright Year
2020
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-32-9931-3_10

Premium Partners