Skip to main content
Top
Published in: Fire Technology 1/2023

05-12-2022

Full-Scale Fire Performance of Combustible and Non-combustible Curtain Wall Systems with Firestops

Authors: Dharmit Nakrani, Gaurav Srivastava

Published in: Fire Technology | Issue 1/2023

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Facade systems used in modern buildings have received much attention in recent times due to their involvement in the propagation of fires in various incidents. These systems comprise of multiple components—cladding frame (typically of aluminum), façade panels (glass, aluminum composite panels, etc.), perimeter firestop (to seal the gap between floor and façade) and spandrel fire protection (typically provided from the inside of a compartment). While many standardized testing methods exist for quantifying their fire performance, most of them consider the behavior of individual components in isolation. The test conditions are also quite different from those encountered in real fire scenarios. The current study highlights these gaps and provides inferences from six full-scale real fire experiments conducted in a three-storey structure with different façade (curtain wall) and firestop configurations. Combustible façade panels of aluminum composite panels (ACP) and medium density fiberboard (MDF) and non-combustible glass panels of single glazed units and double-glazed units were utilized whereas two different methods of edge of the slab firestop and spandrel insulation were employed. The fire scenarios were developed at all floor levels (fire loads as well as initial ventilation conditions) as per realistic residential/office type dwellings. It was found that once the flames leap out of the fire compartment due to the failure of the façade panels, the spandrel area was subjected to 31 kW/m2 of additional heat flux, which indicated the need to consider fire protection of the spandrel area from the outside, especially for combustible façade systems. Further, one of the firestop installation methods was found to be more robust to address site tolerances and installation uncertainties arising due to workmanship as it allowed significantly less ingress of hot gases and toxic fumes to the upper floors. In terms of the two combustible panels, ACP and MDF, it was found that there were differences in their performance in a bench-scale experiment (cone calorimeter) and the full-scale experiments. MDF was found to perform better in the full-scale experiments. The method used for securement of the façade panels (pressure tape/silicone sealant and screws) was also found to have significant effect on the overall performance of the façade system; the failure mechanism of the façade panels was found to be different in both cases. It is expected that the findings presented in this study will provide insights to the real performance of different façade components as a system and will help in improving the codes and standards in the future.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Appendix
Available only for authorised users
Literature
1.
go back to reference Carbary LD, Yee S, Bagatelos N (2014) Architectural insulation modules: thermal and structural performance for use in curtainwall construction. Carbary LD, Yee S, Bagatelos N (2014) Architectural insulation modules: thermal and structural performance for use in curtainwall construction.
2.
go back to reference Klee C and Love A (2014) Thermal performance of façades. Boston, USA. Klee C and Love A (2014) Thermal performance of façades. Boston, USA.
4.
go back to reference Martin M-B (2019) Grenfell tower inquiry: phase 1 report. Ministry of Housing Communities & Local Government, UK Martin M-B (2019) Grenfell tower inquiry: phase 1 report. Ministry of Housing Communities & Local Government, UK
6.
go back to reference Nguyen K, Weerasinghe P, Mendis P, Ngo T, Barnett J (2016) Performance of modern building façades in fire: a comprehensive review. Electron J Struct Eng 16(1):69–86CrossRef Nguyen K, Weerasinghe P, Mendis P, Ngo T, Barnett J (2016) Performance of modern building façades in fire: a comprehensive review. Electron J Struct Eng 16(1):69–86CrossRef
8.
go back to reference Nathan W, Delichatsios M (2015) Fire hazards of exterior wall assemblies containing combustible components. Springer-Verlag, New York Nathan W, Delichatsios M (2015) Fire hazards of exterior wall assemblies containing combustible components. Springer-Verlag, New York
9.
go back to reference Routley JG (1988) Interstate Bank building fire Los Angeles, California. Technical Report, Federal Emergency Management Agency (FEMA) Routley JG (1988) Interstate Bank building fire Los Angeles, California. Technical Report, Federal Emergency Management Agency (FEMA)
10.
go back to reference Woodward J, Singh BB (2020) Firestopping everything you need to know about. International Code Council Woodward J, Singh BB (2020) Firestopping everything you need to know about. International Code Council
13.
go back to reference Srivastava G, Nakrani D, Ghoroi C (2020) Performance of combustible facade systems with glass, ACP and firestops in full-scale, real fire experiments. Fire Technol 56(4):1575–1598CrossRef Srivastava G, Nakrani D, Ghoroi C (2020) Performance of combustible facade systems with glass, ACP and firestops in full-scale, real fire experiments. Fire Technol 56(4):1575–1598CrossRef
14.
go back to reference Bisby L (2018) Grenfell tower inquiry. Phase 1-final expert report, UK Bisby L (2018) Grenfell tower inquiry. Phase 1-final expert report, UK
17.
go back to reference Ariyanayagam AD, Mahendran M (2013) Fire safety of buildings based on realistic fire time-temperature curves. In: Proceedings of the 19th international CIB World Building Congress, Brisbane 2013: construction and society, pp. 1–13 Ariyanayagam AD, Mahendran M (2013) Fire safety of buildings based on realistic fire time-temperature curves. In: Proceedings of the 19th international CIB World Building Congress, Brisbane 2013: construction and society, pp. 1–13
18.
go back to reference National Building Code of India - part 4: Fire And Life Safety (2005) Standard. Bureau of Indian Standards, New Delhi National Building Code of India - part 4: Fire And Life Safety (2005) Standard. Bureau of Indian Standards, New Delhi
19.
go back to reference Srivastava G et al (2018) Development of a unique full-scale real-fire façade testing facility at IIT Gandhinagar. Curr Sci 115(9):1782–1787CrossRef Srivastava G et al (2018) Development of a unique full-scale real-fire façade testing facility at IIT Gandhinagar. Curr Sci 115(9):1782–1787CrossRef
20.
go back to reference ASTM D792–20 (2020) Standard test methods for density and specific gravity (relative density) of plastics by displacement. ASTM International, West Conshohocken, PA ASTM D792–20 (2020) Standard test methods for density and specific gravity (relative density) of plastics by displacement. ASTM International, West Conshohocken, PA
21.
go back to reference “ASTM E1269 (2005) Standard test method for determining specific heat capacity by differential scanning calorimetry, West Conshohocken, PA “ASTM E1269 (2005) Standard test method for determining specific heat capacity by differential scanning calorimetry, West Conshohocken, PA
22.
24.
go back to reference Shah J, Jan MR, Mabood F, Jabeen F (2010) Catalytic pyrolysis of LDPE leads to valuable resource recovery and reduction of waste problems. Energy Convers Manage 51(12):2791–2801CrossRef Shah J, Jan MR, Mabood F, Jabeen F (2010) Catalytic pyrolysis of LDPE leads to valuable resource recovery and reduction of waste problems. Energy Convers Manage 51(12):2791–2801CrossRef
25.
go back to reference “ISO 5660-1:2015 (2015) Reaction-to-fire tests—heat release, smoke production and mass loss rate—part 1: heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) “ISO 5660-1:2015 (2015) Reaction-to-fire tests—heat release, smoke production and mass loss rate—part 1: heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)
26.
go back to reference Nakrani D, Wani T, Srivastava G (2020) Simulation of pyrolysis and combustion of pine wood using two-step reaction scheme. Nakrani D, Wani T, Srivastava G (2020) Simulation of pyrolysis and combustion of pine wood using two-step reaction scheme.
27.
go back to reference Larsson O (2008) Shear capacity in adhesive glass-joints. Master’s Thesis, Division of Structural Mechanics, Lund University Larsson O (2008) Shear capacity in adhesive glass-joints. Master’s Thesis, Division of Structural Mechanics, Lund University
30.
go back to reference Roy A, Chawhan RS, Patel R, Varadharajan S, Tiwari LM, Chakraborty AL, Ghoroi C, Srivastava G (2019) Quantifying the CO and CO2 mole fraction in the plume of an aerosol-based fire extinguishing agent using 4560 nm and 4320 nm QCLs. IEEE Sens J 19(21):9728–9735CrossRef Roy A, Chawhan RS, Patel R, Varadharajan S, Tiwari LM, Chakraborty AL, Ghoroi C, Srivastava G (2019) Quantifying the CO and CO2 mole fraction in the plume of an aerosol-based fire extinguishing agent using 4560 nm and 4320 nm QCLs. IEEE Sens J 19(21):9728–9735CrossRef
31.
go back to reference “EN 1991-1-2 (2002) Eurocode 1: action on structures—part 1–2: general actions on structures exposed to fire. Standard “EN 1991-1-2 (2002) Eurocode 1: action on structures—part 1–2: general actions on structures exposed to fire. Standard
32.
go back to reference Nagy N (2020) Determination of thermal properties of mineral wool insulation materials for use in full-scale fire modelling. Master’s thesis, Mechanical and Mechatronics Engineering, University of Waterloo, Ontario, Canada, 2020. Nagy N (2020) Determination of thermal properties of mineral wool insulation materials for use in full-scale fire modelling. Master’s thesis, Mechanical and Mechatronics Engineering, University of Waterloo, Ontario, Canada, 2020.
33.
go back to reference Holicky M, Meterna A, Sedlacek G, Schleich JB (2005) Implementation of Eurocodes, handbook 5, design of buildings for the fire situation. Luxembourg: Lenoardo da Vinci Pilot Project Holicky M, Meterna A, Sedlacek G, Schleich JB (2005) Implementation of Eurocodes, handbook 5, design of buildings for the fire situation. Luxembourg: Lenoardo da Vinci Pilot Project
34.
go back to reference Peng L, Ni Z (2006) Experimental study of window-ejected flame and plume on glass curtain walls. In: MATEC web of conferences 46, 05009, EDP Sciences Peng L, Ni Z (2006) Experimental study of window-ejected flame and plume on glass curtain walls. In: MATEC web of conferences 46, 05009, EDP Sciences
35.
go back to reference Babrauskas V (2011) Glass breakage in fires. Fire Science and Technology, Inc, pp 1–7 Babrauskas V (2011) Glass breakage in fires. Fire Science and Technology, Inc, pp 1–7
36.
go back to reference Hassani SK, Shields TJ, Silcock GW (1994) An experimental investigation into the behavior of glazing in enclosure fire. J Appl Fire Sci 4:303–323CrossRef Hassani SK, Shields TJ, Silcock GW (1994) An experimental investigation into the behavior of glazing in enclosure fire. J Appl Fire Sci 4:303–323CrossRef
37.
go back to reference Xie Q, Zhang H, Wan Y, Zhang Q, Cheng X (2008) Full-scale experimental study on crack and fallout of toughened glass with different thicknesses. Fire Mater 32:293–306CrossRef Xie Q, Zhang H, Wan Y, Zhang Q, Cheng X (2008) Full-scale experimental study on crack and fallout of toughened glass with different thicknesses. Fire Mater 32:293–306CrossRef
Metadata
Title
Full-Scale Fire Performance of Combustible and Non-combustible Curtain Wall Systems with Firestops
Authors
Dharmit Nakrani
Gaurav Srivastava
Publication date
05-12-2022
Publisher
Springer US
Published in
Fire Technology / Issue 1/2023
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-022-01342-y

Other articles of this Issue 1/2023

Fire Technology 1/2023 Go to the issue