Gaze Stability During Ocular Proton Therapy: Quantitative Evaluation Based on Eye Surface Surveillance Videos

Authors : Rosalinda Ricotti, Andrea Pella, Giovanni Elisei, Barbara Tagaste, Federico Bello, Giulia Fontana, Maria Rosaria Fiore, Mario Ciocca, Edoardo Mastella, Ester Orlandi, Guido Baroni

Published in: Pattern Recognition. ICPR International Workshops and Challenges

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Ocular proton therapy (OPT) is acknowledged as a therapeutic option for the treatment of ocular melanomas. OPT clinical workflow is deeply based on x-ray image guidance procedures, both for treatment planning and patient setup verification purposes. An optimized eye orientation relative to the proton beam axis is determined during treatment planning and it is reproduced during treatment by focusing the patient gaze on a fixation light conveniently positioned in space. Treatment geometry verification is routinely performed through stereoscopic radiographic images while real time patient gaze reproducibility is qualitatively monitored by visual control of eye surface images acquired by dedicated optical cameras. We described an approach to quantitatively evaluate the stability of patients’ gaze direction over an OPT treatment course at the National Centre of Oncological Hadrontherapy (Centro Nazionale di Adroterapia Oncologica, CNAO, Pavia, Italy).
Pupil automatic segmentation procedure was implemented on eye surveillance videos of five patients recorded during OPT. Automatic pupil detection performance was benchmarked against manual pupil contours of four different clinical operators. Stability of patients’ gaze direction was quantified. 2D distances were expressed as percentage of the reference pupil radius.
Valuable approximation between circular fitting and manual contours was observed. Inter-operator manual contours 2D distances were in median (interquartile range) 3.3% (3.6%) of the of the reference pupil radius. The median (interquartile range) of 2D distances between the automatic segmentations and the manual contours was 5.0% (5.3) of the of the reference pupil radius. Stability of gaze direction varied across patients with median values ranging between 6.6% and 16.5% of reference pupil radius.
The measured pupil displacement on the camera field of view were clinically acceptable. Further developments are necessary to reach a real-time clip-less quantification of eye during OPT.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Olsen, D.R., Bruland, O.S., Frykholm, G., Norderhaug, I.N.: Proton therapy – a systematic review of clinical effectiveness. Radiother Oncol. 83, 123–132 (2007)CrossRef Olsen, D.R., Bruland, O.S., Frykholm, G., Norderhaug, I.N.: Proton therapy – a systematic review of clinical effectiveness. Radiother Oncol. 83, 123–132 (2007)CrossRef
2.
go back to reference Wang, Z., et al.: Charged particle radiation therapy for uveal melanoma: a systematic review and meta-analysis. Int. J. Radiat. Oncol. Biol. Phys. 86(1), 18–26 (2013) Wang, Z., et al.: Charged particle radiation therapy for uveal melanoma: a systematic review and meta-analysis. Int. J. Radiat. Oncol. Biol. Phys. 86(1), 18–26 (2013)
3.
go back to reference Maschi, C., Thariat, J., Herault, J., Caujolle, J.: Tumor response in uveal melanomas treated with proton beam therapy. Clin. Oncol. 28, 198–203 (2015)CrossRef Maschi, C., Thariat, J., Herault, J., Caujolle, J.: Tumor response in uveal melanomas treated with proton beam therapy. Clin. Oncol. 28, 198–203 (2015)CrossRef
4.
go back to reference Sikuade, M.J., et al.: Outcomes of treatment with stereotactic radiosurgery or proton beam therapy for choroidal melanoma. Eye 29(9), 1194–1198 (2015) Sikuade, M.J., et al.: Outcomes of treatment with stereotactic radiosurgery or proton beam therapy for choroidal melanoma. Eye 29(9), 1194–1198 (2015)
6.
go back to reference Carnicer, A., Angellier, G., Thariat, J., Sauerwein, W., Caujolle, J.P., Herault, J.: Quantification of dose perturbations induced by external and internal accessories in ocular proton therapy and evaluation of their dosimetric impact. Med. Phys. 40(6), 061708 (2013 ). https://doi.org/10.1118/1.4807090. PMID: 23718587CrossRef Carnicer, A., Angellier, G., Thariat, J., Sauerwein, W., Caujolle, J.P., Herault, J.: Quantification of dose perturbations induced by external and internal accessories in ocular proton therapy and evaluation of their dosimetric impact. Med. Phys. 40(6), 061708 (2013 ). https://​doi.​org/​10.​1118/​1.​4807090. PMID: 23718587CrossRef
8.
11.
13.
21.
22.
go back to reference Setiawan, M.T., Wibirama, S., Setiawan, N.A.: Robust pupil localization algorithm based on circular hough transform for extreme pupil occlusion. In: 2018 4th International Conference on Science and Technology (ICST), Yogyakarta, 2018, pp. 1–5 (2018). https://doi.org/10.1109/ICSTC.2018.8528286. Setiawan, M.T., Wibirama, S., Setiawan, N.A.: Robust pupil localization algorithm based on circular hough transform for extreme pupil occlusion. In: 2018 4th International Conference on Science and Technology (ICST), Yogyakarta, 2018, pp. 1–5 (2018). https://​doi.​org/​10.​1109/​ICSTC.​2018.​8528286.
Metadata
Title
Gaze Stability During Ocular Proton Therapy: Quantitative Evaluation Based on Eye Surface Surveillance Videos
Authors
Rosalinda Ricotti
Andrea Pella
Giovanni Elisei
Barbara Tagaste
Federico Bello
Giulia Fontana
Maria Rosaria Fiore
Mario Ciocca
Edoardo Mastella
Ester Orlandi
Guido Baroni
Copyright Year
2021
DOI
https://doi.org/10.1007/978-3-030-68796-0_32

Premium Partner