Gel Impedance Used as a Pressure Sensor: Preliminary Results

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Pressure sensing by measuring the impedance of soft matter, like hydrogels and rubber, has so far posed the problems of low conductivity and hysteresis. Further modifications in the materials to enhance their properties are needed. A pressure sensor using a simple gelatin/agarose double network gel placed between two Ag/AgCl electrodes is presented. The impedance spectra from 100 Hz to 1 MHz were investigated and admittance calculated. Both response time and hysteresis were also investigated. All the experiments were made using an impedance analyzer from Zurich Instruments. Results showed that the lowest standard deviation is at 3.5 kHz. It was found that the admittance increases exponentially from 7.9 to approximately 11.7 mS with increasing the mechanical load at 3.5 kHz. The highest hysteresis of about ±7.6% was found to be at zero load. The measured response time of the gel impedance was approximately 0.5 s, which makes the double network gel feasible for real time pressure monitoring. Mechanical tests measuring the force on the gel due to deformation showed little influence of the gel structure on the impedance. Thus it was concluded that the change of the distance in between the electrodes is responsible for the impedance change of the gel. Calibrations will be necessary for practical applications, since the gel impedance changes as environmental conditions change. This sensor showed better results as compared to conductive rubber published in the literature. It can be concluded that agarose/gelatin gels provide a cheap and easy to fabricate pressure measuring device.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Pollack, G.H.: The cell as a biomaterial. J. Mater. Sci. Mater. Med. 13, 811–821 (2002)CrossRef Pollack, G.H.: The cell as a biomaterial. J. Mater. Sci. Mater. Med. 13, 811–821 (2002)CrossRef
2.
go back to reference Peppas, N.A., Hilt, Z., Khademhosseini, A., Langer, R.: Hydrogels in biology and medicine: from molecular principles to bionanotechnology. Adv. Mater. 18, 1345–1360 (2006)CrossRef Peppas, N.A., Hilt, Z., Khademhosseini, A., Langer, R.: Hydrogels in biology and medicine: from molecular principles to bionanotechnology. Adv. Mater. 18, 1345–1360 (2006)CrossRef
3.
4.
go back to reference Peak, C.W., Wilker, J.J., Schmidt, G.: A review on tough and sticky hydrogels. Colloid Polym. Sci. 291, 2031–2047 (2013)CrossRef Peak, C.W., Wilker, J.J., Schmidt, G.: A review on tough and sticky hydrogels. Colloid Polym. Sci. 291, 2031–2047 (2013)CrossRef
5.
go back to reference Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., Adler, H.-J.P.: Review on hydrogel-based pH sensors and microsensors. Sensors 8, 561–581 (2008)CrossRef Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., Adler, H.-J.P.: Review on hydrogel-based pH sensors and microsensors. Sensors 8, 561–581 (2008)CrossRef
6.
go back to reference Miao, Y., Zhang, K., Yuam, Y., Liu, B., Zhang, H., Liu, Y., Yao, J.: Agarose gel-coated LPG based on two sensing mechanisms for relative humidity measurement. Appl. Opt. 52(1), 90–95 (2013)CrossRef Miao, Y., Zhang, K., Yuam, Y., Liu, B., Zhang, H., Liu, Y., Yao, J.: Agarose gel-coated LPG based on two sensing mechanisms for relative humidity measurement. Appl. Opt. 52(1), 90–95 (2013)CrossRef
7.
go back to reference Sawahata, K., Gong, J.P., Osada, Y.: Soft and wet touch-sensing system made of hydrogel. Macromol. Rapid Commun. 16, 713–716 (1995)CrossRef Sawahata, K., Gong, J.P., Osada, Y.: Soft and wet touch-sensing system made of hydrogel. Macromol. Rapid Commun. 16, 713–716 (1995)CrossRef
8.
go back to reference Osada, Y., Gong, J.-P.: Soft and wet materials: polymer gels. Adv. Mater. 10(11), 827–837 (1998)CrossRef Osada, Y., Gong, J.-P.: Soft and wet materials: polymer gels. Adv. Mater. 10(11), 827–837 (1998)CrossRef
9.
go back to reference González-Correa, C.A., Brown, B.H., Smallwood, R.H., Walker, D.C., Bardhan, K.D.: Electrical bioimpedance readings increase with higher pressure applied to the measuring probe. Physiol. Meas. 26, 39–47 (2005)CrossRef González-Correa, C.A., Brown, B.H., Smallwood, R.H., Walker, D.C., Bardhan, K.D.: Electrical bioimpedance readings increase with higher pressure applied to the measuring probe. Physiol. Meas. 26, 39–47 (2005)CrossRef
10.
go back to reference Dodde, R.E., Bull, J.L., Shih, A.J.: Bioimpedance of soft tissue under compression. Physiol. Meas. 33, 1095–1109 (2012)CrossRef Dodde, R.E., Bull, J.L., Shih, A.J.: Bioimpedance of soft tissue under compression. Physiol. Meas. 33, 1095–1109 (2012)CrossRef
11.
go back to reference Belmont, B., Dodde, R.E., Shih, A.J.: Impedance of tissue-mimicking phantom material under compression. J. Electr. Bioimp. 4, 2–12 (2013)CrossRef Belmont, B., Dodde, R.E., Shih, A.J.: Impedance of tissue-mimicking phantom material under compression. J. Electr. Bioimp. 4, 2–12 (2013)CrossRef
12.
go back to reference Gu, W.Y., Yao, H., Vega, A.L., Flagler, D.: Diffusivity of ions in agarose gels and intervertebral disc: effect of porosity. Ann. Biomed. Engin. 32(12), 1710–1717 (2004)CrossRef Gu, W.Y., Yao, H., Vega, A.L., Flagler, D.: Diffusivity of ions in agarose gels and intervertebral disc: effect of porosity. Ann. Biomed. Engin. 32(12), 1710–1717 (2004)CrossRef
13.
go back to reference Gu, W.Y., Justiz, M.A., Yao, H.: Electrical conductivity of limbar annulus fibrosis: effects of porosity and fixed charge density. Spine 27(21), 2390–2395 (2002)CrossRef Gu, W.Y., Justiz, M.A., Yao, H.: Electrical conductivity of limbar annulus fibrosis: effects of porosity and fixed charge density. Spine 27(21), 2390–2395 (2002)CrossRef
14.
go back to reference Somboon, N., Karilla, T.T., Kaewmanee, T., Karilla, S.J.: Properties of gels from mixed agar and fish gelatin. IFRJ 21(2), 485–492 (2014) Somboon, N., Karilla, T.T., Kaewmanee, T., Karilla, S.J.: Properties of gels from mixed agar and fish gelatin. IFRJ 21(2), 485–492 (2014)
15.
go back to reference Mei, H., Zhang, C., Wang, R., Feng, J., Zhang, T.: Impedance characteristics of surface pressure-sensitive carbon black/silicone rubber composites. Sens. Actuator A 233, 118–124 (2015)CrossRef Mei, H., Zhang, C., Wang, R., Feng, J., Zhang, T.: Impedance characteristics of surface pressure-sensitive carbon black/silicone rubber composites. Sens. Actuator A 233, 118–124 (2015)CrossRef
16.
go back to reference Khalili, N., Naguib, H.E., Kwon, R.H.: A constriction resistance model of conjugated polymer based piezoresistive sensors for electronic skin applications. Soft Matter 12, 4180–4189 (2016)CrossRef Khalili, N., Naguib, H.E., Kwon, R.H.: A constriction resistance model of conjugated polymer based piezoresistive sensors for electronic skin applications. Soft Matter 12, 4180–4189 (2016)CrossRef
Metadata
Title
Gel Impedance Used as a Pressure Sensor: Preliminary Results
Authors
Simon Brunnquell
Vinicius Sirtoli
Pedro Bertemes-Filho
Copyright Year
2020
DOI
https://doi.org/10.1007/978-3-030-30648-9_190