Skip to main content
Top

2014 | OriginalPaper | Chapter

9. Human Factors in Power Plant Maintenance

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In power plant maintenance, human factors play an important role because by improving the maintainability design of power plant systems, equipment, and facilities in regard to human factors helps to increase plant safety, availability, and productivity. In comparison to the aerospace industrial sector, interest in human factors-related issues in the power industrial sector is relatively new.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference US Nuclear Regulatory Commission (1975) Reactor safety study: an assessment of accident risks in US commercial nuclear power plants. Report No. WASH-1400, US Nuclear Regulatory Commission, Washington US Nuclear Regulatory Commission (1975) Reactor safety study: an assessment of accident risks in US commercial nuclear power plants. Report No. WASH-1400, US Nuclear Regulatory Commission, Washington
2.
go back to reference Seminara JL, Gonzalez WR, Parsons SO (1976) Human factors review of nuclear power plant control room design. Report No. EPRI NP-309, Electric Power Research Institute (EPRI), Palo Alto Seminara JL, Gonzalez WR, Parsons SO (1976) Human factors review of nuclear power plant control room design. Report No. EPRI NP-309, Electric Power Research Institute (EPRI), Palo Alto
3.
go back to reference Seminara JL, Parsons SO (1985) Human factors engineering and power plant maintenance. Maintenance Manage Int 6:33–71 Seminara JL, Parsons SO (1985) Human factors engineering and power plant maintenance. Maintenance Manage Int 6:33–71
4.
go back to reference Dhillon BS (2009) Human reliability, error, and human factors in engineering maintenance: with reference to aviation and power generation. CRC Press, Boca RatonCrossRef Dhillon BS (2009) Human reliability, error, and human factors in engineering maintenance: with reference to aviation and power generation. CRC Press, Boca RatonCrossRef
5.
go back to reference Seminara JL, Parsons SO (1981) Human factors review of power plant maintainability. Report No. EPRI NP-1567, Electric Power Research Institute, Palo Alto Seminara JL, Parsons SO (1981) Human factors review of power plant maintainability. Report No. EPRI NP-1567, Electric Power Research Institute, Palo Alto
6.
go back to reference Penington J, Shakeri S (2006) A human factors approach to effective maintenance. In: Proceedings of 27th annual Canadian Nuclear Society (CNS) conference, pp 1–11 Penington J, Shakeri S (2006) A human factors approach to effective maintenance. In: Proceedings of 27th annual Canadian Nuclear Society (CNS) conference, pp 1–11
7.
go back to reference Kinkade RG (1988) Human factors primer for nuclear utility managers. Report No. EPRI NP-5714, Electric Power Research Institute, Palo Alto Kinkade RG (1988) Human factors primer for nuclear utility managers. Report No. EPRI NP-5714, Electric Power Research Institute, Palo Alto
8.
go back to reference Shriver EL, Zach SE, Foley JP (1982) Test of job performance aids for power plants. Report No. EPRI NP. 2676, Electric Power Research Institute, Palo Alto Shriver EL, Zach SE, Foley JP (1982) Test of job performance aids for power plants. Report No. EPRI NP. 2676, Electric Power Research Institute, Palo Alto
9.
go back to reference Pariftt B (1986) First use: frozen water garment use at TMI-2. Report No. EPRI 4102B (RP 1705), Electric Power Research Institute, Palo Alto Pariftt B (1986) First use: frozen water garment use at TMI-2. Report No. EPRI 4102B (RP 1705), Electric Power Research Institute, Palo Alto
10.
go back to reference Annual Report (1982) Electric Power Research Institute, Palo Alto Annual Report (1982) Electric Power Research Institute, Palo Alto
11.
go back to reference Seminara JL (1982) Human factors methods for assessing and enhancing power plant maintainability. Report No. EPRI NP-2360, Electric Power Research Institute, Palo Alto Seminara JL (1982) Human factors methods for assessing and enhancing power plant maintainability. Report No. EPRI NP-2360, Electric Power Research Institute, Palo Alto
Metadata
Title
Human Factors in Power Plant Maintenance
Author
B. S. Dhillon
Copyright Year
2014
DOI