Abstract

The conductivity distribution inside a volume conductor can be reconstructed with Electrical Impedance Tomography (EIT). Therefore, electrodes on the surface of the volume conductor are used to inject a constant current and measure the resulting surface potentials, which is equivalent to transfer impedances. A sequence of current injections and voltage measurements is called measurement pattern and results in a set of transfer impedances. Various measurement patterns exist and each of them has a specific sensitivity, which influences the distinguishability of an object in the reconstructed image. To compare different patterns we introduced three criteria based on the RAW-measurement and evaluated the performance in a water-tank experiment. Measurement patterns with an increased distance between the injecting and measuring electrodes showed more sensitivity and selectivity in the RAW-data and should be preferably chosen compared to the traditional adjacent pattern.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Adler, A., Gaggero, P.O., Maimaitijiang, Y.: Adjacent stimulation and measurement patterns considered harmful. Physiol. Meas. 32, 731–744 (2011)CrossRef Adler, A., Gaggero, P.O., Maimaitijiang, Y.: Adjacent stimulation and measurement patterns considered harmful. Physiol. Meas. 32, 731–744 (2011)CrossRef
2.
go back to reference Kleinermann, F., Avis, N.J., Judah, S.K., et al.: Image reconstruction using non-adjacent drive configurations (electric impedance tomography). Physiol. Meas. IS 15, A153 (1994)CrossRef Kleinermann, F., Avis, N.J., Judah, S.K., et al.: Image reconstruction using non-adjacent drive configurations (electric impedance tomography). Physiol. Meas. IS 15, A153 (1994)CrossRef
3.
go back to reference Pasi, K., Jari, H., Jaakko, M.: Sensitivity distribution simulations of impedance tomography electrode combinations. Int. J. Bioelectromag. 7, 344–347 (2005) Pasi, K., Jari, H., Jaakko, M.: Sensitivity distribution simulations of impedance tomography electrode combinations. Int. J. Bioelectromag. 7, 344–347 (2005)
4.
go back to reference Jossinet, J., Kardous, G.: Physical study of the sensitivity distribution in multi-electrode systems. Clin. Phy. Physiol. Meas. 8, 33 (1987)CrossRef Jossinet, J., Kardous, G.: Physical study of the sensitivity distribution in multi-electrode systems. Clin. Phy. Physiol. Meas. 8, 33 (1987)CrossRef
5.
go back to reference Geselowitz, D.B.: An application of electrodynamic lead theory to impendance plethysmonography. IEEE Trans. Bio-Med. Eng. 18, 38–41 (1971)CrossRef Geselowitz, D.B.: An application of electrodynamic lead theory to impendance plethysmonography. IEEE Trans. Bio-Med. Eng. 18, 38–41 (1971)CrossRef
6.
go back to reference Jaakko, M., Plonsey, R.: Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields. Oxford University Press (1995) Jaakko, M., Plonsey, R.: Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields. Oxford University Press (1995)
7.
go back to reference Aguiar, S.S., Robens, A., Boehm, A., Leonhardt, S., Teichmann, D.: System description and first application of an FPGA-based simultaneous multi-frequency electrical impedance tomography. Sensors (Switzerland) 16(8), E1158 (2016)CrossRef Aguiar, S.S., Robens, A., Boehm, A., Leonhardt, S., Teichmann, D.: System description and first application of an FPGA-based simultaneous multi-frequency electrical impedance tomography. Sensors (Switzerland) 16(8), E1158 (2016)CrossRef
Metadata
Title
Influence of Measurement Pattern on RAW-data in Electrical Impedance Tomography
Authors
Tobias Menden
Tobias Textor
Samantha Schadwinkel
Steffen Leonhardt
Marian Walter
Copyright Year
2020
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-13-3498-6_2