Skip to main content
Top
Published in: Wireless Personal Communications 4/2018

01-02-2018

RETRACTED ARTICLE: Internet of Things Based Industrial Automation Using Brushless DC Motor Application with Resilient Directed Neural Network Control FED Virtual Z-Source Multilevel Inverter Topology

Authors: S. Sivaranjani, R. Rajeswari

Published in: Wireless Personal Communications | Issue 4/2018

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Internet of Things (IoT) is a high-speed communication technology which has carnal substances or devices entrenched with sensors, system connectivity, which allows to receive and interchange data. Industrial Monitoring and Control is required to assemble all the material information, statistics, and data related to the various industrial processes, motors, machines and devices employed in industrial premises. The technological improvements, remote control and monitoring via communication techniques such as wireless sensor network techniques have been widely used in Industries. Competitive advantages over AC motors make for DC motors to replace other electrical engines in applications stretching from high-speed automation to electric motorbikes. BLDC drives are very popular in many industries, at present automation are added standard, Virtual Z-source multilevel is a respectable optimal that can boost the output voltage of the drive. A novel soft computing based Resilient Directed Neural network (RDNN) found Virtual Z-source multilevel inverter, for BLDC motor drive control to make the system balanced when the load is unbalanced and to reduce the electrical torque pulsation. In this work, the utilization of the RDNN to tackle the reduced harmonics issue in VZS-MLI converters is proposed. This strategy permits active voltage control of the crucial and besides concealment of a particular set of harmonics. The performance is evaluated in various emphasis levels of the different control models. The sensors monitor the technical motor parameters like greatest rise and fall time, topmost overextend and inaccuracy value of load current and voltage in BLDC machine. Then the measured values are sent to the processing unit, which will analyze and display the parameters, where the processing unit also communicates with Gateway module to send information to cloud database for remote monitoring. The system also presents the Automatic and manual control methods to stop or start the BLDC machine to avoid system failures.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Durgasukumar, D. G., & Pathak, M. K. (2012). Comparison of adaptive neuro-fuzzy-based space-vector modulation for the two-level inverter. International Journal of Electrical Power & Energy Systems, 38(1), 9–19.CrossRef Durgasukumar, D. G., & Pathak, M. K. (2012). Comparison of adaptive neuro-fuzzy-based space-vector modulation for the two-level inverter. International Journal of Electrical Power & Energy Systems, 38(1), 9–19.CrossRef
2.
go back to reference Charumit, C., & Kinnares, V. (2015). Discontinuous SVPWM techniques of three-leg VSI-fed balanced two-phase loads for reduced switching losses and current ripple. IEEE Transactions on Power Electronics, 30(4), 2191–2204.CrossRef Charumit, C., & Kinnares, V. (2015). Discontinuous SVPWM techniques of three-leg VSI-fed balanced two-phase loads for reduced switching losses and current ripple. IEEE Transactions on Power Electronics, 30(4), 2191–2204.CrossRef
3.
go back to reference Zheng, P., Wang, P., Sui, Y., Tong, C., Wu, F., & Li, T. (2014). Near-five-vector SVPWM algorithm for five-phase six-leg inverters under unbalanced load conditions. Journal of Power Electronics, 14(1), 61–73.CrossRef Zheng, P., Wang, P., Sui, Y., Tong, C., Wu, F., & Li, T. (2014). Near-five-vector SVPWM algorithm for five-phase six-leg inverters under unbalanced load conditions. Journal of Power Electronics, 14(1), 61–73.CrossRef
4.
go back to reference Fan, Y., Zhang, L., Cheng, M., & Chau, K. (2015). Sensorless SVPWM-FADTC of a new flux-modulated permanent-magnet wheel motor based on a wide-speed sliding mode observer. IEEE Transactions on Industrial Electronics, 62(5), 3143–3151.CrossRef Fan, Y., Zhang, L., Cheng, M., & Chau, K. (2015). Sensorless SVPWM-FADTC of a new flux-modulated permanent-magnet wheel motor based on a wide-speed sliding mode observer. IEEE Transactions on Industrial Electronics, 62(5), 3143–3151.CrossRef
5.
go back to reference Mutanga, O., Adam, E., Adjorlolo, C., & Abdel-Rahman, E. M. (2015). Evaluating the robustness of models developed from field spectral data in predicting African grass foliar nitrogen concentration using worldview-2 image as an independent test dataset. International Journal of Applied Earth Observation and Geoinformation, 34, 178–187.CrossRef Mutanga, O., Adam, E., Adjorlolo, C., & Abdel-Rahman, E. M. (2015). Evaluating the robustness of models developed from field spectral data in predicting African grass foliar nitrogen concentration using worldview-2 image as an independent test dataset. International Journal of Applied Earth Observation and Geoinformation, 34, 178–187.CrossRef
6.
go back to reference Bhat, A. H., & Agarwal, P. (2009). Implementation of a neural-network-based space vector pulse-width modulation for a three-phase neutral-point clamped high-power factor converter. Electric Power Components and Systems, 37(2), 210–233.CrossRef Bhat, A. H., & Agarwal, P. (2009). Implementation of a neural-network-based space vector pulse-width modulation for a three-phase neutral-point clamped high-power factor converter. Electric Power Components and Systems, 37(2), 210–233.CrossRef
7.
go back to reference Piao, C., & Hung, J. Y. (2015). A simplified and unified space vector PWM algorithm for multilevel diode clamped VSI. In Proceedings of the IEEE international conference on industrial technology (pp. 2770–2776). Piao, C., & Hung, J. Y. (2015). A simplified and unified space vector PWM algorithm for multilevel diode clamped VSI. In Proceedings of the IEEE international conference on industrial technology (pp. 2770–2776).
8.
go back to reference Mehrizi-Sani, A., & Filizadeh, S. (2009). An optimized space vector modulation sequence for improved harmonic performance. IEEE Transactions on Industrial Electronics, 56(8), 2894–2903.CrossRef Mehrizi-Sani, A., & Filizadeh, S. (2009). An optimized space vector modulation sequence for improved harmonic performance. IEEE Transactions on Industrial Electronics, 56(8), 2894–2903.CrossRef
9.
go back to reference Xueguang, Z., Wenjie, Z., Jiaming, C., & Dianguo, X. (2014). Deadbeat control strategy of circulating currents in parallel connection system of three-phase PWM converter. IEEE Transactions on Energy Conversion, 29(2), 406–417.CrossRef Xueguang, Z., Wenjie, Z., Jiaming, C., & Dianguo, X. (2014). Deadbeat control strategy of circulating currents in parallel connection system of three-phase PWM converter. IEEE Transactions on Energy Conversion, 29(2), 406–417.CrossRef
10.
go back to reference Pan, S., Pan, J., & Tian, Z. (2012). A shifted SVPWM method to control DC-link resonant inverters and its FPGA realization. IEEE Transactions on Industrial Electronics, 59(9), 3383–3391.CrossRef Pan, S., Pan, J., & Tian, Z. (2012). A shifted SVPWM method to control DC-link resonant inverters and its FPGA realization. IEEE Transactions on Industrial Electronics, 59(9), 3383–3391.CrossRef
11.
go back to reference Liang, T. J., O’Connell, R. M., & Hoft, R. G. (1997). Inverter harmonic reduction using Walsh function harmonic elimination method. IEEE Transactions on Power Electronics, 12, 971–982.CrossRef Liang, T. J., O’Connell, R. M., & Hoft, R. G. (1997). Inverter harmonic reduction using Walsh function harmonic elimination method. IEEE Transactions on Power Electronics, 12, 971–982.CrossRef
12.
go back to reference Langer, N., Bhat, A. H., & Agarwal, P. (2014). Neural-network-based space-vector pulse-width modulation for capacitor voltage balancing of three phase three-level improved power quality converter. IET Power Electronics, 7(4), 973–983.CrossRef Langer, N., Bhat, A. H., & Agarwal, P. (2014). Neural-network-based space-vector pulse-width modulation for capacitor voltage balancing of three phase three-level improved power quality converter. IET Power Electronics, 7(4), 973–983.CrossRef
13.
go back to reference Swift, F., & Kamberis, A. (1993). A new Walsh domain technique of harmonic elimination and voltage control in pulse-width modulated inverters. IEEE Transactions on Power Electronics, 8, 170–185.CrossRef Swift, F., & Kamberis, A. (1993). A new Walsh domain technique of harmonic elimination and voltage control in pulse-width modulated inverters. IEEE Transactions on Power Electronics, 8, 170–185.CrossRef
14.
go back to reference Dahidah, M. S. A., & Agelidis, V. G. (2008). Reduced harmonics PWM control for cascaded multilevel voltage source converters: A generalized formula. IEEE Transactions on Power Electronics, 23, 1620–1630.CrossRef Dahidah, M. S. A., & Agelidis, V. G. (2008). Reduced harmonics PWM control for cascaded multilevel voltage source converters: A generalized formula. IEEE Transactions on Power Electronics, 23, 1620–1630.CrossRef
15.
go back to reference Kennedy, J., & Eberhart, R. (1995). Particle swarm optimization. In ICNN’95 IEEE international conference on neural networks (Vol. 4, pp. 1942–1948). Kennedy, J., & Eberhart, R. (1995). Particle swarm optimization. In ICNN’95 IEEE international conference on neural networks (Vol. 4, pp. 1942–1948).
16.
go back to reference Azab, M. (2010). Particle swarm optimization-based solutions for selective harmonic elimination in single-phase PWM inverters. International Journal of Power Electronics, 2, 125–142.CrossRef Azab, M. (2010). Particle swarm optimization-based solutions for selective harmonic elimination in single-phase PWM inverters. International Journal of Power Electronics, 2, 125–142.CrossRef
17.
go back to reference Debnath, S., & Ray, R. N. (2012). THD optimization in 13-level photovoltaic inverter using genetic algorithm. International Journal of Engineering Research and Applications, 2, 385–389. Debnath, S., & Ray, R. N. (2012). THD optimization in 13-level photovoltaic inverter using genetic algorithm. International Journal of Engineering Research and Applications, 2, 385–389.
18.
go back to reference Kavousi, A., Vahidi, B., & Salehi, R. (2012). Application of the bee algorithm for reduced harmonics strategy in multilevel inverters. IEEE Transactions on power Electronics, 27, 1689–1696.CrossRef Kavousi, A., Vahidi, B., & Salehi, R. (2012). Application of the bee algorithm for reduced harmonics strategy in multilevel inverters. IEEE Transactions on power Electronics, 27, 1689–1696.CrossRef
19.
go back to reference Dahidah, M. S. A., Agelidis, V. G., & Rao, M. V. (2008). Hybrid genetic algorithm approach for selective harmonic control. Energy Conversion and Management, 49, 131–142.CrossRef Dahidah, M. S. A., Agelidis, V. G., & Rao, M. V. (2008). Hybrid genetic algorithm approach for selective harmonic control. Energy Conversion and Management, 49, 131–142.CrossRef
20.
go back to reference Filho, F., Maia, H. Z., Mateus, H. A., Ozpineci, B., Tolbert, L. M., & Pinto, J. O. P. (2013). Adaptive selective harmonic minimization based on ANNs for cascade multilevel inverters with varying DC sources. IEEE Transactions on Industrial Electronics, 60, 1955–1962.CrossRef Filho, F., Maia, H. Z., Mateus, H. A., Ozpineci, B., Tolbert, L. M., & Pinto, J. O. P. (2013). Adaptive selective harmonic minimization based on ANNs for cascade multilevel inverters with varying DC sources. IEEE Transactions on Industrial Electronics, 60, 1955–1962.CrossRef
21.
go back to reference Enjeti, C. B. P., Ziogas, P. D., & Lindsay, J. F. (1990). Programmed pwm techniques to eliminate harmonics: A critical evaluation. IEEE Transactions on Industry Applications, 26, 302–316.CrossRef Enjeti, C. B. P., Ziogas, P. D., & Lindsay, J. F. (1990). Programmed pwm techniques to eliminate harmonics: A critical evaluation. IEEE Transactions on Industry Applications, 26, 302–316.CrossRef
22.
go back to reference Cetin, A., & Ermis, M. (2009). VSC-based D-STATCOM with selective harmonic elimination. IEEE Transactions on Industry Applications, 45, 1000–1015.CrossRef Cetin, A., & Ermis, M. (2009). VSC-based D-STATCOM with selective harmonic elimination. IEEE Transactions on Industry Applications, 45, 1000–1015.CrossRef
23.
go back to reference Cetin, A., & Ermis, M. (2007). VSC based D-STATCOM with selective harmonic elimination. In IEEE 42nd industry applications conference (IAS’07) (Vol. 1, pp. 936–948). Cetin, A., & Ermis, M. (2007). VSC based D-STATCOM with selective harmonic elimination. In IEEE 42nd industry applications conference (IAS’07) (Vol. 1, pp. 936–948).
24.
go back to reference Abu-Rub, H., Guzinski, J., Krzeminski, Z., & Toliyat, H. A. (2004). Predictive current control of voltage source inverters. IEEE Transactions on Industrial Electronics, 51(3), 585–593.CrossRef Abu-Rub, H., Guzinski, J., Krzeminski, Z., & Toliyat, H. A. (2004). Predictive current control of voltage source inverters. IEEE Transactions on Industrial Electronics, 51(3), 585–593.CrossRef
25.
go back to reference Zeng, Q., & Chang, L. (2008). An advanced SVPWM-based predictive current controller for three-phase inverters in distributed generation systems. IEEE Transactions on Industrial Electronics, 55(3), 1235–1246.CrossRef Zeng, Q., & Chang, L. (2008). An advanced SVPWM-based predictive current controller for three-phase inverters in distributed generation systems. IEEE Transactions on Industrial Electronics, 55(3), 1235–1246.CrossRef
26.
go back to reference Peng, F. Z. (2003). Z-source inverter. IEEE Transactions on Industry Applications, 39(2), 504–510.CrossRef Peng, F. Z. (2003). Z-source inverter. IEEE Transactions on Industry Applications, 39(2), 504–510.CrossRef
27.
go back to reference Peng, F. Z. (2002). Z source inverter. In IAS annual meeting conference on industry applications conference, 13–18 Oct. 2002 (Vol. 2, pp. 775–781). Peng, F. Z. (2002). Z source inverter. In IAS annual meeting conference on industry applications conference, 13–18 Oct. 2002 (Vol. 2, pp. 775–781).
28.
go back to reference Luo, Z, Alam, M., & Hong, S. H. (2015). A hardware-in-the-loop simulator for demand response energy management in industrial facilities. In Proceedings of 2015 IEEE workshop on modeling and simulation of cyber-physical energy systems (MSCPES) (Vol. 618). Luo, Z, Alam, M., & Hong, S. H. (2015). A hardware-in-the-loop simulator for demand response energy management in industrial facilities. In Proceedings of 2015 IEEE workshop on modeling and simulation of cyber-physical energy systems (MSCPES) (Vol. 618).
29.
go back to reference Wei, M., Hong, S. H., & Alam, M. (2016). An IoT-based energy-management platform for industrial facilities. Applied Energy, 164, 607–619.CrossRef Wei, M., Hong, S. H., & Alam, M. (2016). An IoT-based energy-management platform for industrial facilities. Applied Energy, 164, 607–619.CrossRef
30.
go back to reference May, G., Barletta, I., Stahl, B., & Taisch, M. (2015). Energy management in production: A novel method to develop key performance indicators for improving energy efficiency. Applied Energy, 149, 46–61.CrossRef May, G., Barletta, I., Stahl, B., & Taisch, M. (2015). Energy management in production: A novel method to develop key performance indicators for improving energy efficiency. Applied Energy, 149, 46–61.CrossRef
Metadata
Title
RETRACTED ARTICLE: Internet of Things Based Industrial Automation Using Brushless DC Motor Application with Resilient Directed Neural Network Control FED Virtual Z-Source Multilevel Inverter Topology
Authors
S. Sivaranjani
R. Rajeswari
Publication date
01-02-2018
Publisher
Springer US
Published in
Wireless Personal Communications / Issue 4/2018
Print ISSN: 0929-6212
Electronic ISSN: 1572-834X
DOI
https://doi.org/10.1007/s11277-018-5365-6

Other articles of this Issue 4/2018

Wireless Personal Communications 4/2018 Go to the issue