Skip to main content
Top

2022 | OriginalPaper | Chapter

Method for Improved Image Reconstruction in Computed Tomography and Positron Emission Tomography, Based on Compressive Sensing with Prefiltering in the Frequency Domain

Authors : Y. Garcia, C. Franco, C. J. Miosso

Published in: XXVII Brazilian Congress on Biomedical Engineering

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Computed tomography (CT) and positron emission tomography (PET) allow many types of diagnoses and medical analyses to be performed, as well as patient monitoring in different treatment scenarios. Therefore, they are among the most important medical imaging modalities, both in clinical applications and in scientific research. However, both methods lead to radiation exposure, associated to the X-rays, used in the CT case, and to the chemical contrast that inserts a radioactive isotope into the patient’s body, in the PET case. It is possible to reduce the amount of radiation needed to attain a specified quality in these imaging techniques by using compressive sensing (CS), which reduces the number of measurements required for signal and image reconstruction, compared to standard approaches such as filtered backprojection. In this paper, we propose and evaluate a new method for the reconstruction of CT and PET images based on CS with prefiltering in the frequency domain. We start by estimating frequency-domain measurements based on the acquired sinograms. Next, we perform a prefiltering in the frequency domain to favor the sparsity required by CS and improve the reconstruction of filtered versions of the image. Based on the reconstructed filtered images, a final composition stage leads to the complete image using the spectral information from the individual filtered versions. We compared the proposed method to the standard filtered backprojection technique, commonly used in CT and PET. The results suggest that the proposed method can lead to images with significantly higher signal-to-error ratios for a specified number of measurements, both for CT (p = 8.8324e-05) and PET (p = 4.7377e-09).

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
[1]
go back to reference Markoe A (2006) Analytic tomography. Encyclopedia of mathematics and its applications. Cambridge University Press, Cambridge Markoe A (2006) Analytic tomography. Encyclopedia of mathematics and its applications. Cambridge University Press, Cambridge
[2]
go back to reference Halperin EC, Wazer DE, Perez CA, Brady LW (2018) Perez & Brady’s principles and practice of radiation oncology. Lippincott Williams & Wilkins (LWW), 7th edn Halperin EC, Wazer DE, Perez CA, Brady LW (2018) Perez & Brady’s principles and practice of radiation oncology. Lippincott Williams & Wilkins (LWW), 7th edn
[3]
go back to reference Rubin GD (2014) Computed tomography: revolutionizing the practice of medicine for 40 years. Radiology 273:181–200CrossRef Rubin GD (2014) Computed tomography: revolutionizing the practice of medicine for 40 years. Radiology 273:181–200CrossRef
[4]
go back to reference Chiffre L, Carmignato S, Kruth J et al (2014) Industrial applications of computed tomography. CIRP Ann 63:655–677CrossRef Chiffre L, Carmignato S, Kruth J et al (2014) Industrial applications of computed tomography. CIRP Ann 63:655–677CrossRef
[5]
go back to reference Bryan RN (2009) Introduction to the science of medical imaging. Cambridge University Press, Cambridge Bryan RN (2009) Introduction to the science of medical imaging. Cambridge University Press, Cambridge
[6]
go back to reference Donnan GA, Ma H, Mohr JP, In: Mohr J, Choi D et al (eds) Overview of laboratory studies in stroke, 4th edn. Churchill Liv. 978-0-443-06600-9 Donnan GA, Ma H, Mohr JP, In: Mohr J, Choi D et al (eds) Overview of laboratory studies in stroke, 4th edn. Churchill Liv. 978-0-443-06600-9
[7]
go back to reference Kurle P, Rutecki P (2010) Seizures and epilepsy. In: Rolak LA (ed) Neurology secrets, 5th edn. Mosby, Philadelphia, pp 315–339 Kurle P, Rutecki P (2010) Seizures and epilepsy. In: Rolak LA (ed) Neurology secrets, 5th edn. Mosby, Philadelphia, pp 315–339
[8]
go back to reference D’Ascenzo N, Antonecchia E, Gao M et al (2020) Evaluation of a digital brain PET scanner based on the plug imaging sensor technology. IEEE Trans Radiat Plasma Med Sci 4:327–334CrossRef D’Ascenzo N, Antonecchia E, Gao M et al (2020) Evaluation of a digital brain PET scanner based on the plug imaging sensor technology. IEEE Trans Radiat Plasma Med Sci 4:327–334CrossRef
[9]
go back to reference Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284 PMID: 18046031CrossRef Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284 PMID: 18046031CrossRef
[10]
go back to reference Brenner DJ, Doll R, Head DT et al (2003) Good. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. In: Proceedings of the national academy of sciences of the United States of America, vol 100 Brenner DJ, Doll R, Head DT et al (2003) Good. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. In: Proceedings of the national academy of sciences of the United States of America, vol 100
[11]
go back to reference Seeram E (2001) Computed tomography: physical principles, clinical applications, and quality control. Saunders, W.B Seeram E (2001) Computed tomography: physical principles, clinical applications, and quality control. Saunders, W.B
[12]
go back to reference Miosso CJ, Borries R, Pierluissi JH (2013) Compressive sensing with prior information: requirements and probabilities of reconstruction in l1-minimization. IEEE Trans Sig Process 61:2150–2164CrossRef Miosso CJ, Borries R, Pierluissi JH (2013) Compressive sensing with prior information: requirements and probabilities of reconstruction in l1-minimization. IEEE Trans Sig Process 61:2150–2164CrossRef
[13]
go back to reference Miosso CJ, Borries R, Pierluissi JH (2009) Compressive sensing method for improved reconstruction of gradient-sparse magnetic resonance images. In: 2009 conference record of the forty-third Asilomar conference on signals, systems and computers, pp 799–806 Miosso CJ, Borries R, Pierluissi JH (2009) Compressive sensing method for improved reconstruction of gradient-sparse magnetic resonance images. In: 2009 conference record of the forty-third Asilomar conference on signals, systems and computers, pp 799–806
[14]
go back to reference Lustig M (2008) Sparse MRI. PhD thesis. Stanford University, Department of Electrical Engineering Lustig M (2008) Sparse MRI. PhD thesis. Stanford University, Department of Electrical Engineering
[15]
go back to reference Miosso CJ (2010) Compressive sensing with prior information applied to magnetic resonance imaging. Ph.D. thesis, University of Texas at El Paso—UTEP, Department of Electrical and Computer Engineering, TX Miosso CJ (2010) Compressive sensing with prior information applied to magnetic resonance imaging. Ph.D. thesis, University of Texas at El Paso—UTEP, Department of Electrical and Computer Engineering, TX
[16]
go back to reference Lima JA, Miosso CJ, Farias MC, Borries R (2018) Evaluation of different types of filters in magnetic resonance imaging using compressive sensing with pre-filtering. EMBC 2018, HI, USA, July 18–21, 2018, 5575–5578 Lima JA, Miosso CJ, Farias MC, Borries R (2018) Evaluation of different types of filters in magnetic resonance imaging using compressive sensing with pre-filtering. EMBC 2018, HI, USA, July 18–21, 2018, 5575–5578
[17]
go back to reference Kak AC, Slaney M (2001) Principles of computerized tomographic imaging. Society for Industrial and Applied Mathematics, PA Kak AC, Slaney M (2001) Principles of computerized tomographic imaging. Society for Industrial and Applied Mathematics, PA
[18]
go back to reference de Boor C (2001) A practical guide to splines, Revised edn. Springer, New York de Boor C (2001) A practical guide to splines, Revised edn. Springer, New York
[19]
go back to reference Miosso CJ, Borries R, Argaez M et al (2009) Compressive sensing reconstruction with prior information by iteratively reweighted least-squares. IEEE Trans Sig 57:2424–2431 Miosso CJ, Borries R, Argaez M et al (2009) Compressive sensing reconstruction with prior information by iteratively reweighted least-squares. IEEE Trans Sig 57:2424–2431
[20]
[21]
go back to reference Qure.ai . Non-contrast head/brain CT CQ500 dataset. Creative commons attribution-noncommercial-ShareAlike 4.0 international license. Available at http://headctstudy.qure.ai/. Last access: June 13th 2020 Qure.ai . Non-contrast head/brain CT CQ500 dataset. Creative commons attribution-noncommercial-ShareAlike 4.0 international license. Available at http://​headctstudy.​qure.​ai/​. Last access: June 13th 2020
[23]
go back to reference Neuroimaging Institute, Southern California Informatics Keck School. LONI Image and Data Archive 2019. https://ida.loni.usc.edu/ Neuroimaging Institute, Southern California Informatics Keck School. LONI Image and Data Archive 2019. https://​ida.​loni.​usc.​edu/​
Metadata
Title
Method for Improved Image Reconstruction in Computed Tomography and Positron Emission Tomography, Based on Compressive Sensing with Prefiltering in the Frequency Domain
Authors
Y. Garcia
C. Franco
C. J. Miosso
Copyright Year
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_295