Skip to main content
Top

2021 | OriginalPaper | Chapter

Methods and Techniques for Increasing the Accuracy of Continuous Non-invasive Blood Pressure Measurement Under Dynamic Loads

Authors : Gleb Zaitsev, Alexei Vassiliev, Quang-Kien Trinh

Published in: Proceedings of International Scientific Conference on Telecommunications, Computing and Control

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In this paper, various methods for measuring blood pressure (BP) are considered and discussed in detail. Among those, we focus on the indirect BP measurement using the volume clamp method (VC). We considered a hardware solution using the SAKR-2 (Ltd Intox) device for non-invasive BP measurement. Based on our experimental results, this solution is well suited to BP dynamics measure for the patients both at rest and during movement. Specifically, by analyzing the characteristics of multiple measured results in different scenarios, we have proposed several post-processing techniques to remove the systematic errors during measurements (e.g., due to the measurement condition) and enhance accuracy. Compared to the conventional direct BP measurement methods in the radial artery (RA) using commercial device (S5 monitor), both systolic blood pressure (SBP) and diastolic blood pressure (DBP) indicators have strong relationship. The measured BP shifts with respect to hydrostatic changes in blood pressure are fairly match to the theoretical predetermined value during repetitive measurements.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Agabiti-Rosei, E., et al.: Central blood pressure measurements and antihypertensive therapy: a consensus document. Hypertension 50, 154–160 (2007)CrossRef Agabiti-Rosei, E., et al.: Central blood pressure measurements and antihypertensive therapy: a consensus document. Hypertension 50, 154–160 (2007)CrossRef
2.
go back to reference Gupta, B.: Invasive blood pressure monitoring. Update Anaethesia 28, 37–42 (2012) Gupta, B.: Invasive blood pressure monitoring. Update Anaethesia 28, 37–42 (2012)
3.
go back to reference Durie, M., Beckmann, U., Gillies, D.M.: Incidents relating to arterial cannulation as identified in 7.525 reports submitted to the Australian incident monitoring study (AIMS-ICU). Anaesth Intensive Care 30(1), 60–65 (2002) Durie, M., Beckmann, U., Gillies, D.M.: Incidents relating to arterial cannulation as identified in 7.525 reports submitted to the Australian incident monitoring study (AIMS-ICU). Anaesth Intensive Care 30(1), 60–65 (2002)
4.
go back to reference Scheer, B., Perel, A., Pfeiffer, U.J.: Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 6 (2002) Scheer, B., Perel, A., Pfeiffer, U.J.: Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 6 (2002)
5.
go back to reference Esper, S.A., Pinsky, M.R.: Arterial waveform analysis. Best Pract. Res. Clinical Anaesthesiol. 28, 363–380 (2014)CrossRef Esper, S.A., Pinsky, M.R.: Arterial waveform analysis. Best Pract. Res. Clinical Anaesthesiol. 28, 363–380 (2014)CrossRef
6.
go back to reference Thiele, R.H., Durieux, M.E.: Arterial waveform analysis for the anesthesiologist: past, present, and future concepts. Anesth Analgesia 113(4), 766–776 (2011)CrossRef Thiele, R.H., Durieux, M.E.: Arterial waveform analysis for the anesthesiologist: past, present, and future concepts. Anesth Analgesia 113(4), 766–776 (2011)CrossRef
7.
go back to reference Avolio, A.P., van Bortel, L.M., Boutouyrie, P., et al.: Role of pulse pressure amplification in arterial hypertension: experts opinion and review of the data. Hypertension 54(2), 375–383 (2009)CrossRef Avolio, A.P., van Bortel, L.M., Boutouyrie, P., et al.: Role of pulse pressure amplification in arterial hypertension: experts opinion and review of the data. Hypertension 54(2), 375–383 (2009)CrossRef
8.
go back to reference Williams, B., et al.: 2018 ESC/ESH guidelines for the management of arterial hypertension. Eur. Heart J. 39(31), 3021–3104 (2018)CrossRef Williams, B., et al.: 2018 ESC/ESH guidelines for the management of arterial hypertension. Eur. Heart J. 39(31), 3021–3104 (2018)CrossRef
9.
go back to reference Pickering, T.G.: Blood pressure variability and ambulatory monitoring. Curr. Opin. Nephrol. Hypertens. 2(3), 380–385 (1993)CrossRef Pickering, T.G.: Blood pressure variability and ambulatory monitoring. Curr. Opin. Nephrol. Hypertens. 2(3), 380–385 (1993)CrossRef
10.
go back to reference Marchenko, V., Noskin, L., Pivovarov, V., et al.: Prognostic and diagnostic value of moderate intensity stress test with blood pressure control. In: The Scientific Notes of the I. P. Pavlov St. Petersburg State Medical University, vol. 21, issue 4, pp. 18–21 (2014) Marchenko, V., Noskin, L., Pivovarov, V., et al.: Prognostic and diagnostic value of moderate intensity stress test with blood pressure control. In: The Scientific Notes of the I. P. Pavlov St. Petersburg State Medical University, vol. 21, issue 4, pp. 18–21 (2014)
11.
go back to reference Miyai, N., Arita, M., Miyashita, K., et al.: Blood pressure response to heart rate during exercise test and risk of future hypertension. Hypertension 39(8), 761–766 (2002)CrossRef Miyai, N., Arita, M., Miyashita, K., et al.: Blood pressure response to heart rate during exercise test and risk of future hypertension. Hypertension 39(8), 761–766 (2002)CrossRef
12.
go back to reference Schultz, M.G., Otahal, P., Cleland, V.J., et al.: Exercise-induced hypertension, cardiovascular events, and mortality in patients undergoing exercise stress testing: a systematic review and meta-analysis. Am. J. Hypertens. 26(3), 357–366 (2013)CrossRef Schultz, M.G., Otahal, P., Cleland, V.J., et al.: Exercise-induced hypertension, cardiovascular events, and mortality in patients undergoing exercise stress testing: a systematic review and meta-analysis. Am. J. Hypertens. 26(3), 357–366 (2013)CrossRef
13.
go back to reference Penaz, J.: Photoelectric measurement of blood pressure, volume and flow in the finger. In: Proceedings of the Conference Committee of the 10th International Conference on Medicine and Biological Engineering, pp. 104, Dresden (1973) Penaz, J.: Photoelectric measurement of blood pressure, volume and flow in the finger. In: Proceedings of the Conference Committee of the 10th International Conference on Medicine and Biological Engineering, pp. 104, Dresden (1973)
14.
go back to reference Guelen, I., Westerhof, B.E., Van Der Sar, G.L., Van Montfrans, G.A., Kiemeneij, F., Wesseling, K.H., Bos, W.J.: Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. Blood Press Monit. 8(1), 27–30 (2003)CrossRef Guelen, I., Westerhof, B.E., Van Der Sar, G.L., Van Montfrans, G.A., Kiemeneij, F., Wesseling, K.H., Bos, W.J.: Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. Blood Press Monit. 8(1), 27–30 (2003)CrossRef
15.
go back to reference Schutte, A.E., Huisman, H.W., Van Rooyen, J.M., Malan, N.T., Schutte, R.: Validation of the Finometer device for measurement of blood pressure in black women. J. Hum. Hypertens. 18(2), 79–84 (2004)CrossRef Schutte, A.E., Huisman, H.W., Van Rooyen, J.M., Malan, N.T., Schutte, R.: Validation of the Finometer device for measurement of blood pressure in black women. J. Hum. Hypertens. 18(2), 79–84 (2004)CrossRef
16.
go back to reference Silke, B., McAuley, D.: Accuracy and precision of blood pressure determination with the Finapres: an overview using re-sampling statistics. J. Hum. Hypertens. 12(6), 403–409 (1998)CrossRef Silke, B., McAuley, D.: Accuracy and precision of blood pressure determination with the Finapres: an overview using re-sampling statistics. J. Hum. Hypertens. 12(6), 403–409 (1998)CrossRef
17.
go back to reference Imholz, B.P., Settels, J.J., Van der Meiracker, A.H., Wesseling, K.H., Wieling, W.: Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc. Res. 24(3), 214–221 (1990)CrossRef Imholz, B.P., Settels, J.J., Van der Meiracker, A.H., Wesseling, K.H., Wieling, W.: Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc. Res. 24(3), 214–221 (1990)CrossRef
18.
go back to reference Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., Mancia, G.: Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing. Hypertension 13(6 Pt 1), 647–655 (1989)CrossRef Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., Mancia, G.: Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing. Hypertension 13(6 Pt 1), 647–655 (1989)CrossRef
19.
go back to reference Pivovarov, V.V.: A Spiroarteriocardiorhythmograph. Biomed. Eng. 40(1), 45–47 (2016)CrossRef Pivovarov, V.V.: A Spiroarteriocardiorhythmograph. Biomed. Eng. 40(1), 45–47 (2016)CrossRef
20.
go back to reference Pivovarov, V.V., Zaytsev, G.K., Sizov, V.V.: Adaptive exercise stress system SAKR-VELO for load tests. Biomed. Eng. 49(2), 74–78 (2015)CrossRef Pivovarov, V.V., Zaytsev, G.K., Sizov, V.V.: Adaptive exercise stress system SAKR-VELO for load tests. Biomed. Eng. 49(2), 74–78 (2015)CrossRef
Metadata
Title
Methods and Techniques for Increasing the Accuracy of Continuous Non-invasive Blood Pressure Measurement Under Dynamic Loads
Authors
Gleb Zaitsev
Alexei Vassiliev
Quang-Kien Trinh
Copyright Year
2021
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-33-6632-9_12