Abstract

A low-frequency, omni-directional A0 Lamb wave ElectroMagnetic Acoustic Transducer (EMAT) is developed for applications in guided wave tomography, operating at 50 kHz on a 10 mm thick steel plate. The key objective is to excite an acceptably pure A0 wave mode in relation to the S0 mode, which can also be present at this operating point and is desired to be suppressed by approximately 30 dB. For that, a parametric Finite Element (FE) model of the design concept is implemented in a commercially available FE software, where the bias magnetic field is calculated initially, then combined with the eddy current caused by the induction coil to produce a force. A numerical optimization process employing a genetic algorithm is set up and the EMAT design is optimized to yield an improved A0 mode selectivity. The parameters subjected to optimization are the magnet diameter and the magnet lift-off, which control the direction of the exciting force in the skin depth layer and therefore the mode selectivity. Although there are three possible electromagnetic acoustic interaction mechanisms, the optimisation considers only the Lorentz force, as its performance surface contains a clear optimum and from the optimised design a physical prototype is built. The FE model is validated against measurements on an aluminium plate for the Lorentz force excitation mechanism and on a steel plate for both the Lorentz and magnetisation force. For the steel plate, it is found that only considering the Lorentz force leads to a significant overestimation of the mode selectivity, as the S0 amplitude is underestimated by the Lorentz force, but the A0 amplitude remains mainly uninfluenced. Further, it has been found that additionally including the magnetisation force into the optimisation leads to a better mode selectivity, however, the optimisation drives the optimum to a minimum magnet diameter and therefore reduces the EMAT sensitivity. In a numerical study robustness is shown for fairly large variations of the magnet lift-off and the magnetic permeability. Based on the findings, a two-step model-based design approach is proposed whereby only the Lorentz force is used in the first step for the optimisation and then in a second step, a realistic estimate of the mode selectivity of the optimised design can be obtained by additionally considering the magnetisation force.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Hou, J., Leonard, K.R., Hinders, M.K.: Automatic multi-mode Lamb wave arrival time extraction for improved tomographic reconstruction. Inverse Probl. 20(6), 1873–1888 (2004)MATHMathSciNetCrossRef Hou, J., Leonard, K.R., Hinders, M.K.: Automatic multi-mode Lamb wave arrival time extraction for improved tomographic reconstruction. Inverse Probl. 20(6), 1873–1888 (2004)MATHMathSciNetCrossRef
2.
go back to reference Miller, C.A., Hinders, M.K.: Classification of flaw severity using pattern recognition for guided wave-based structural health monitoring. Ultrasonics 54(1), 247–258 (2014)CrossRef Miller, C.A., Hinders, M.K.: Classification of flaw severity using pattern recognition for guided wave-based structural health monitoring. Ultrasonics 54(1), 247–258 (2014)CrossRef
3.
go back to reference Volker, A., Vos, H.: Experimental results of guided wave travel time tomography. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in QNDE, AIP Conference Proceedings, vol. 1430(1), pp. 1968–1975 (2012) Volker, A., Vos, H.: Experimental results of guided wave travel time tomography. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in QNDE, AIP Conference Proceedings, vol. 1430(1), pp. 1968–1975 (2012)
4.
go back to reference Volker, A., Vos, R.: Annular plate inspection using guided wave tomography. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in QNDE, AIP Conference Proceedings, vol. 1511, pp. 745–752 (2013) Volker, A., Vos, R.: Annular plate inspection using guided wave tomography. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in QNDE, AIP Conference Proceedings, vol. 1511, pp. 745–752 (2013)
5.
go back to reference Volker, A., van Zon, T.: Guided wave travel time tomography for bends. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in QNDE, Chimenti, AIP Conference Proceedings, vol. 1511, pp. 737–744 (2013) Volker, A., van Zon, T.: Guided wave travel time tomography for bends. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in QNDE, Chimenti, AIP Conference Proceedings, vol. 1511, pp. 737–744 (2013)
7.
go back to reference Huthwaite, P.: Evaluation of inversion approaches for guided wave thickness mapping. In: Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, vol. 470(2166) (2014) Huthwaite, P.: Evaluation of inversion approaches for guided wave thickness mapping. In: Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, vol. 470(2166) (2014)
8.
go back to reference Huthwaite, P., Ribichini, R., Cawley, P., Lowe, M.J.S.: Mode selection for corrosion detection in pipes and vessels via guided wave tomography. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 60, 1165–1177 (2013)CrossRef Huthwaite, P., Ribichini, R., Cawley, P., Lowe, M.J.S.: Mode selection for corrosion detection in pipes and vessels via guided wave tomography. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 60, 1165–1177 (2013)CrossRef
9.
go back to reference Belanger, P., Cawley, P., Simonetti, F.: Guided wave diffraction tomography within the Born approximation. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57, 1405–1418 (2010)CrossRef Belanger, P., Cawley, P., Simonetti, F.: Guided wave diffraction tomography within the Born approximation. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57, 1405–1418 (2010)CrossRef
10.
go back to reference Hirao, M., Ogi, H.: EMATs for Science and Industry: Noncontacting Ultrasonic Measurements. Kluwer Academic Publishers, Philip Drive Norwell (2003)CrossRef Hirao, M., Ogi, H.: EMATs for Science and Industry: Noncontacting Ultrasonic Measurements. Kluwer Academic Publishers, Philip Drive Norwell (2003)CrossRef
11.
go back to reference Wilcox, P.D., Lowe, M.J.S., Cawley, P.: The excitation and detection of Lamb waves with planar coil electromagnetic acoustic transducers. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 52, 2370–2383 (2005)CrossRef Wilcox, P.D., Lowe, M.J.S., Cawley, P.: The excitation and detection of Lamb waves with planar coil electromagnetic acoustic transducers. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 52, 2370–2383 (2005)CrossRef
12.
go back to reference Koch, R.H., May, A., Li, J.: Electromagnetic acoustic transducers for use in ultrasound inspection systems, US Patent 7,426,867 (2008) Koch, R.H., May, A., Li, J.: Electromagnetic acoustic transducers for use in ultrasound inspection systems, US Patent 7,426,867 (2008)
14.
go back to reference Moon, F.C.: Magneto-Solid Mechanics. Wiley, New York (1984) Moon, F.C.: Magneto-Solid Mechanics. Wiley, New York (1984)
15.
go back to reference Jiles, D.: Introduction to Magnetism and Magnetic Materials. Chapman and Hall, London (1998) Jiles, D.: Introduction to Magnetism and Magnetic Materials. Chapman and Hall, London (1998)
16.
go back to reference Jackson, J.: Classical Electrodynamics, 3rd edn. Wiley, New York (1998) Jackson, J.: Classical Electrodynamics, 3rd edn. Wiley, New York (1998)
17.
go back to reference Bellac, M., Levy-Leblond, J.M.: Galilean electromagnetism. Il Nuovo Cimento 14, 217–234 (1973)CrossRef Bellac, M., Levy-Leblond, J.M.: Galilean electromagnetism. Il Nuovo Cimento 14, 217–234 (1973)CrossRef
18.
go back to reference Chian, C.T., Moon, F.C.: Magnetically induced cylindrical stress waves in a thermoelastic conductor. Int. J. Solids Struct. 17, 1021–1035 (1981)MATHCrossRef Chian, C.T., Moon, F.C.: Magnetically induced cylindrical stress waves in a thermoelastic conductor. Int. J. Solids Struct. 17, 1021–1035 (1981)MATHCrossRef
19.
go back to reference Thompson, R.B.: A model for the electromagnetic generation of ultrasonic guided waves in ferromagnetic metal polycrystals. IEEE Trans. Sonics and Ultrason. 25, 7–15 (1978)CrossRef Thompson, R.B.: A model for the electromagnetic generation of ultrasonic guided waves in ferromagnetic metal polycrystals. IEEE Trans. Sonics and Ultrason. 25, 7–15 (1978)CrossRef
20.
go back to reference Brown, W.F.: Magnetic energy formulas and their relation to magnetization theory. Rev. Mod. Phys. 25, 131–135 (1953)CrossRef Brown, W.F.: Magnetic energy formulas and their relation to magnetization theory. Rev. Mod. Phys. 25, 131–135 (1953)CrossRef
21.
22.
go back to reference Ribichini, R., Nagy, P.B., Ogi, H.: The impact of magnetostriction on the transduction of normal bias field EMATs. NDT & E Int. 51, 8–15 (2012)CrossRef Ribichini, R., Nagy, P.B., Ogi, H.: The impact of magnetostriction on the transduction of normal bias field EMATs. NDT & E Int. 51, 8–15 (2012)CrossRef
23.
go back to reference Malvern, L.E.: Introduction to the Mechanics of a Continuous Medium. Prentice-Hall, Englewood Cliffs (1969) Malvern, L.E.: Introduction to the Mechanics of a Continuous Medium. Prentice-Hall, Englewood Cliffs (1969)
24.
go back to reference Achenbach, J.D., Xu, Y.: Wave motion in an isotropic elastic layer generated by a time-harmonic point load of arbitrary direction. J. Acoust. Soc. Am. 106, 83–90 (1999)CrossRef Achenbach, J.D., Xu, Y.: Wave motion in an isotropic elastic layer generated by a time-harmonic point load of arbitrary direction. J. Acoust. Soc. Am. 106, 83–90 (1999)CrossRef
26.
go back to reference Ribichini, R.: Modeling of electromagnetic acoustic transducers, PhD Thesis, Imperial College, London (2011) Ribichini, R.: Modeling of electromagnetic acoustic transducers, PhD Thesis, Imperial College, London (2011)
27.
go back to reference Arnold Magnetic Technologies Corporation, Datasheet of N42 Nd-Fe-B Magnets (2009) Arnold Magnetic Technologies Corporation, Datasheet of N42 Nd-Fe-B Magnets (2009)
28.
go back to reference Chari, M.V.K., Reece, P.: Magnetic field distribution in solid metallic structures in the vicinity of current carrying conductors, and associated Eddy-current losses. IEEE Trans. Power Appar. Syst. 93, 45–56 (1974)CrossRef Chari, M.V.K., Reece, P.: Magnetic field distribution in solid metallic structures in the vicinity of current carrying conductors, and associated Eddy-current losses. IEEE Trans. Power Appar. Syst. 93, 45–56 (1974)CrossRef
29.
go back to reference Nagy, P.B., Simonetti, F., Instanes, G.: Corrosion and erosion monitoring in plates and pipes using constant group velocity Lamb wave inspection. Ultrasonics 54(7), 1832–1841 (2014)CrossRef Nagy, P.B., Simonetti, F., Instanes, G.: Corrosion and erosion monitoring in plates and pipes using constant group velocity Lamb wave inspection. Ultrasonics 54(7), 1832–1841 (2014)CrossRef
30.
go back to reference Winter, G.: Genetic Algorithms in Engineering and Computer Science. Wiley, Chichester (1995) Winter, G.: Genetic Algorithms in Engineering and Computer Science. Wiley, Chichester (1995)
32.
go back to reference Instanes, G., Nagy, P.B., Simonetti, F., Willey, C.L.: Measuring wall thickness loss for a structure, Patent, no. US20140208852 A1 (2014) Instanes, G., Nagy, P.B., Simonetti, F., Willey, C.L.: Measuring wall thickness loss for a structure, Patent, no. US20140208852 A1 (2014)
Metadata
Title
Model-Based Design of Low Frequency Lamb Wave EMATs for Mode Selectivity
Authors
Matthias Seher
Peter Huthwaite
Michael J. S. Lowe
Peter B. Nagy
Publication date
01-09-2015
Publisher
Springer US
Published in
Journal of Nondestructive Evaluation / Issue 3/2015
Print ISSN: 0195-9298
Electronic ISSN: 1573-4862
DOI
https://doi.org/10.1007/s10921-015-0296-6

Other articles of this Issue 3/2015

Journal of Nondestructive Evaluation 3/2015 Go to the issue

Premium Partners