Skip to main content
Top
Published in: Medical & Biological Engineering & Computing 9/2019

26-06-2019 | Original Article

Optimized needle shape reconstruction using experimentally based strain sensors positioning

Authors: Pierre-Loup Schaefer, Grégory Chagnon, Alexandre Moreau-Gaudry

Published in: Medical & Biological Engineering & Computing | Issue 9/2019

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Needles are tools that are used daily during minimally invasive procedures. During the insertions, needles may be affected by deformations which may threaten the success of the procedure. To tackle this problem, needles with embedded strain sensors have been developed and associated with navigation systems. The localization of the needle in the tissues is then obtained in real time by reconstruction from the strain measurements, allowing the physician to optimize its gesture. As the number of strain sensors embedded is limited in number, their positions on the needle have a great impact on the accuracy of the shape reconstruction. The main contribution of this paper is a novel strain sensor positioning method to improve the reconstruction accuracy. A notable feature of our method is the use of experimental needle insertion data, which increases the relevancy of the resulting sensor optimal locations. To the best of the author’s knowledge, no experimentally based needle sensor positioning method has been presented yet. Reconstruction validations from clinical data show that the localization accuracy of the needle tip is improved by almost 40% with optimal locations compared with equidistant locations when reconstructing with two sensor triplets or more.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
2.
go back to reference Adams R, Bischof L (1994) Seeded region growing. IEEE Trans Pattern Anal Mach Intell 16(6):641–647CrossRef Adams R, Bischof L (1994) Seeded region growing. IEEE Trans Pattern Anal Mach Intell 16(6):641–647CrossRef
7.
go back to reference Brett PN, Parker T, Harrison AJ, Thomas TA, Carr A (1997) Simulation of resistance forces acting on surgical needles. Proceedings of the Institution of Mechanical Engineers. Part H: J Eng Med 211(4):335–347 Brett PN, Parker T, Harrison AJ, Thomas TA, Carr A (1997) Simulation of resistance forces acting on surgical needles. Proceedings of the Institution of Mechanical Engineers. Part H: J Eng Med 211(4):335–347
8.
go back to reference Byrd RH, Nocedal J, Waltz RA (2006) Knitro: an integrated package for nonlinear optimization. In: Large-scale nonlinear optimization. Springer, pp 35–59 Byrd RH, Nocedal J, Waltz RA (2006) Knitro: an integrated package for nonlinear optimization. In: Large-scale nonlinear optimization. Springer, pp 35–59
9.
go back to reference Cosserat E, Cosserat F et al (1909) Théorie des corps déformables Cosserat E, Cosserat F et al (1909) Théorie des corps déformables
11.
go back to reference Fouard C, Deram A, Keraval Y, Promayon E (2012) CamiTK: a modular framework integrating visualization, image processing and biomechanical modeling. In: Payan Y (ed) Soft Tissue Biomechanical Modeling for Computer Assisted Surgery, pp 323–354 Fouard C, Deram A, Keraval Y, Promayon E (2012) CamiTK: a modular framework integrating visualization, image processing and biomechanical modeling. In: Payan Y (ed) Soft Tissue Biomechanical Modeling for Computer Assisted Surgery, pp 323–354
12.
go back to reference Guggenheimer H (1989) Computing frames along a trajectory. Comput Aided Geom Des 6(1):77–78CrossRef Guggenheimer H (1989) Computing frames along a trajectory. Comput Aided Geom Des 6(1):77–78CrossRef
13.
go back to reference Hairer E, Wanner G, Lubich C (2006) Geometric Numerical Integration. Structure-preserving Algorithms for Ordinary Differential Equations, 2 edn Hairer E, Wanner G, Lubich C (2006) Geometric Numerical Integration. Structure-preserving Algorithms for Ordinary Differential Equations, 2 edn
14.
go back to reference Haron H, Rehman A, Adi D, Lim S, Saba T (2012) Parameterization method on b-spline curve. Mathematical Problems in Engineering 2012 Haron H, Rehman A, Adi D, Lim S, Saba T (2012) Parameterization method on b-spline curve. Mathematical Problems in Engineering 2012
15.
go back to reference van der Heiden MS, Henken K, Chen LK, van den Bosch BG, van den Braber R, Dankelman J, van den Dobbelsteen J (2012) Accurate and efficient fiber optical shape sensor for mri compatible minimally invasive instruments. https://doi.org/10.1117/12.981141 van der Heiden MS, Henken K, Chen LK, van den Bosch BG, van den Braber R, Dankelman J, van den Dobbelsteen J (2012) Accurate and efficient fiber optical shape sensor for mri compatible minimally invasive instruments. https://​doi.​org/​10.​1117/​12.​981141
18.
go back to reference Hocking G, Hebard S, Mitchell CH (2011) A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia. Region Anesth Pain Med 36(2):162–170CrossRef Hocking G, Hebard S, Mitchell CH (2011) A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia. Region Anesth Pain Med 36(2):162–170CrossRef
21.
go back to reference Kirchhoff G (1859) Uber das gleichgewicht und die bewegung eines unendlich dunnen elastischen stabes. J Reine Angew Math 56:285–313 Kirchhoff G (1859) Uber das gleichgewicht und die bewegung eines unendlich dunnen elastischen stabes. J Reine Angew Math 56:285–313
24.
go back to reference Love AEH (1906) A treatise on the mathematical theory of elasticity, 2 edn Love AEH (1906) A treatise on the mathematical theory of elasticity, 2 edn
26.
go back to reference Mahoney AW, Bruns TL, Swaney PJ, Webster RJ (2016) On the inseparable nature of sensor selection, sensor placement, and state estimation for continuum robots or where to put your sensors and how to use them. In: 2016 IEEE international conference on robotics and automation (ICRA). IEEE, pp 4472– 4478 Mahoney AW, Bruns TL, Swaney PJ, Webster RJ (2016) On the inseparable nature of sensor selection, sensor placement, and state estimation for continuum robots or where to put your sensors and how to use them. In: 2016 IEEE international conference on robotics and automation (ICRA). IEEE, pp 4472– 4478
30.
go back to reference Ng KW, Goh JQ, Foo SL, Ting PH, Lee TK (2013) Needle insertion forces studies for optimal surgical modeling. International Journal of Bioscience. Bioch Bioinforma 3(3):187 Ng KW, Goh JQ, Foo SL, Ting PH, Lee TK (2013) Needle insertion forces studies for optimal surgical modeling. International Journal of Bioscience. Bioch Bioinforma 3(3):187
32.
go back to reference Podder TK, Clark DP, Sherman J (2005) Effects of tip geometry of surgical needle an assessment of force and deflection. Third European medical and biological engineering conference, Prague, Czech Republic, pp 1641–1644 Podder TK, Clark DP, Sherman J (2005) Effects of tip geometry of surgical needle an assessment of force and deflection. Third European medical and biological engineering conference, Prague, Czech Republic, pp 1641–1644
34.
go back to reference Rao CK, Deshpande AP (2010) Modelling of engineering materials. Ane Books Pvt Ltd Rao CK, Deshpande AP (2010) Modelling of engineering materials. Ane Books Pvt Ltd
35.
go back to reference Reissner E (1973) On one-dimensional large-displacement finite-strain beam theory. Stud Appl Math 52 (2):87–95CrossRef Reissner E (1973) On one-dimensional large-displacement finite-strain beam theory. Stud Appl Math 52 (2):87–95CrossRef
38.
go back to reference Rocco Furferi Lapo Governi MPYV (2011) From unordered point cloud to weighted b-spline -. a novel pca-based method - Applications of Mathematics and Computer Engineering Rocco Furferi Lapo Governi MPYV (2011) From unordered point cloud to weighted b-spline -. a novel pca-based method - Applications of Mathematics and Computer Engineering
40.
go back to reference Roesthuis RJ, Janssen S, Misra S (2013) On using an array of fiber bragg grating sensors for closed-loop control of flexible minimally invasive surgical instruments. In: 2013 IEEE/RSJ International conference on intelligent robots and systems, pp 2545–2551. https://doi.org/10.1109/IROS.2013.6696715 Roesthuis RJ, Janssen S, Misra S (2013) On using an array of fiber bragg grating sensors for closed-loop control of flexible minimally invasive surgical instruments. In: 2013 IEEE/RSJ International conference on intelligent robots and systems, pp 2545–2551. https://​doi.​org/​10.​1109/​IROS.​2013.​6696715
41.
go back to reference Rouchy R, Moreau-Gaudry A, Chipon E, Aubry S, Pazart L, Lapuyade B, Durand M, Hajjam M, Pottier S, Renard B, Logier R, Orry X, Cherifi A, Quehen E, Kervio G, Favelle O, Patat F, De Kerviler E, Hughes C, Medici M, Ghelfi J, Mounier A, Bricault I (2017) Evaluation of the clinical benefit of an electromagnetic navigation system for ct-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional ct guidance (ctnav ii): study protocol for a randomised controlled trial. Trials 18(1):306. https://doi.org/10.1186/s13063-017-2049-6 CrossRef Rouchy R, Moreau-Gaudry A, Chipon E, Aubry S, Pazart L, Lapuyade B, Durand M, Hajjam M, Pottier S, Renard B, Logier R, Orry X, Cherifi A, Quehen E, Kervio G, Favelle O, Patat F, De Kerviler E, Hughes C, Medici M, Ghelfi J, Mounier A, Bricault I (2017) Evaluation of the clinical benefit of an electromagnetic navigation system for ct-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional ct guidance (ctnav ii): study protocol for a randomised controlled trial. Trials 18(1):306. https://​doi.​org/​10.​1186/​s13063-017-2049-6 CrossRef
42.
go back to reference Seifabadi R, Gomez EE, Aalamifar F, Fichtinger G, Iordachita I (2013) Real-time tracking of a bevel-tip needle with varying insertion depth: Toward teleoperated mri-guided needle steering. In: 2013 IEEE/RSJ International conference on intelligent robots and systems, pp 469–476. https://doi.org/10.1109/IROS.2013.6696393 Seifabadi R, Gomez EE, Aalamifar F, Fichtinger G, Iordachita I (2013) Real-time tracking of a bevel-tip needle with varying insertion depth: Toward teleoperated mri-guided needle steering. In: 2013 IEEE/RSJ International conference on intelligent robots and systems, pp 469–476. https://​doi.​org/​10.​1109/​IROS.​2013.​6696393
44.
go back to reference Sultan SF, Shorten G, Iohom G (2013) Simulators for training in ultrasound guided procedures. Med Ultrasonogr 15(2):125–131CrossRef Sultan SF, Shorten G, Iohom G (2013) Simulators for training in ultrasound guided procedures. Med Ultrasonogr 15(2):125–131CrossRef
45.
go back to reference Todd MD, Stull CJ, Dickerson M (2013) A local material basis solution approach to reconstructing the three-dimensional displacement of rod-like structures from strain measurements. Journal of Applied Mechanics 80 (4):041028CrossRef Todd MD, Stull CJ, Dickerson M (2013) A local material basis solution approach to reconstructing the three-dimensional displacement of rod-like structures from strain measurements. Journal of Applied Mechanics 80 (4):041028CrossRef
47.
go back to reference Wang W, Jüttler B, Zheng D, Liu Y (2008) Computation of rotation minimizing frames. ACM Trans Graph (TOG) 27(1):2 Wang W, Jüttler B, Zheng D, Liu Y (2008) Computation of rotation minimizing frames. ACM Trans Graph (TOG) 27(1):2
49.
go back to reference Wood GA (1982) Data smoothing and differentiation procedures in biomechanics. Exerc Sport Sci Rev 10 (1):308–362PubMed Wood GA (1982) Data smoothing and differentiation procedures in biomechanics. Exerc Sport Sci Rev 10 (1):308–362PubMed
Metadata
Title
Optimized needle shape reconstruction using experimentally based strain sensors positioning
Authors
Pierre-Loup Schaefer
Grégory Chagnon
Alexandre Moreau-Gaudry
Publication date
26-06-2019
Publisher
Springer Berlin Heidelberg
Published in
Medical & Biological Engineering & Computing / Issue 9/2019
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-019-02001-1

Other articles of this Issue 9/2019

Medical & Biological Engineering & Computing 9/2019 Go to the issue

Premium Partner