Abstract

Vein detection technology has significant applications in many areas such as healthcare, security and aesthetics. In healthcare, vein visualization is highly necessary for making an accurate venipuncture. This work demonstrates a portable hand vein finder system using noninvasive infrared technology that can display the real-time venous image on a monitor. The skin surface is illuminated by a near-infrared (NIR) light source that contains 5 LEDs (850 nm) and 5 LEDs (940 nm). These LEDs are arranged alternately in a circular form. Under NIR light exposition, vein and surrounding tissues are distinguished due to their difference in the brightness and contrast. A 3 MP camera is used to capture the illuminated skin area, and the obtained signal is then transferred to a Raspberry Pi 4 for image processing. The input image is processed with median filtering and contrast-limited adaptive histogram equalization (CLAHE) for displaying on a monitor. After processing, venous images with much better contrast are observed. To project the venous patterns on the skin surface, local adaptive threshold and subsequent morphological image processing are used. After the first algorithm, the venous patterns are segmented out of the image. Then, morphological processing, which has rarely been widely used for vein visualization, further reduces the noise signal, such as hair on the hand thus clearer and sharper venous patterns are obtained. Our work provides an effective and low-cost solution for nursing staff in low and middle-income countries to perform a safe and accurate venipuncture.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Jain et al (2004) An introduction to biometric recognition. IEEE Trans Circuits Syst Video Technol 14(1):4–20 Jain et al (2004) An introduction to biometric recognition. IEEE Trans Circuits Syst Video Technol 14(1):4–20
2.
go back to reference Lee et al (2011) New finger biometric method using near infrared imaging. Sensors 11(3):23192333 Lee et al (2011) New finger biometric method using near infrared imaging. Sensors 11(3):23192333
3.
go back to reference Marathe et al (2014) A novel wireless vein finder. In: International conference on circuits, communication, control and computing. IEEE, Bangalore, India, pp 277–280 Marathe et al (2014) A novel wireless vein finder. In: International conference on circuits, communication, control and computing. IEEE, Bangalore, India, pp 277–280
4.
go back to reference Pan et al (2019) Vein pattern locating technology for cannulation: a review of the low-cost vein finder prototypes utilizing near infrared (NIR) light to improve peripheral subcutaneous vein selection for phlebotomy. Sensors 19(16):3573 Pan et al (2019) Vein pattern locating technology for cannulation: a review of the low-cost vein finder prototypes utilizing near infrared (NIR) light to improve peripheral subcutaneous vein selection for phlebotomy. Sensors 19(16):3573
5.
go back to reference Cope M, Delpy DT (1988) System for long-term measurement of cerebral blood and tissue oxygenation on newborn infants by near infra-red transillumination. Med Biol Eng Comput 26(3):289–294CrossRef Cope M, Delpy DT (1988) System for long-term measurement of cerebral blood and tissue oxygenation on newborn infants by near infra-red transillumination. Med Biol Eng Comput 26(3):289–294CrossRef
6.
go back to reference Tran LT, Pham HTT (2018) Designing and building the vein finder system utilizing nearinfrared technique. In: 7th international conference in Vietnam on the development of biomedical engineering. Springer, Singapore, Vietnam, pp 383–387 Tran LT, Pham HTT (2018) Designing and building the vein finder system utilizing nearinfrared technique. In: 7th international conference in Vietnam on the development of biomedical engineering. Springer, Singapore, Vietnam, pp 383–387
7.
go back to reference Pizer et al (1990) Contrast-limited adaptive histogram equalization: speed and effectiveness. In: Proceedings of the first conference on visualization in biomedical computing. IEEE, Atlanta, USA, pp 337–345 Pizer et al (1990) Contrast-limited adaptive histogram equalization: speed and effectiveness. In: Proceedings of the first conference on visualization in biomedical computing. IEEE, Atlanta, USA, pp 337–345
8.
go back to reference Singh R et al (2011) A new local adaptive thresholding technique in binarization. Int J Comput Sci Issues 8:271–277 Singh R et al (2011) A new local adaptive thresholding technique in binarization. Int J Comput Sci Issues 8:271–277
9.
go back to reference Oh J, Hwang H (2010) Feature enhancement of medical images using morphology-based homomorphic filter and differential evolution algorithm. Int J Control Autom 8(4):857–861CrossRef Oh J, Hwang H (2010) Feature enhancement of medical images using morphology-based homomorphic filter and differential evolution algorithm. Int J Control Autom 8(4):857–861CrossRef
10.
go back to reference Tran VT et al (2017) Design and enhance the vein recognition using near infrared light and projector. Sci Technol Dev J 20(K2):91–95CrossRef Tran VT et al (2017) Design and enhance the vein recognition using near infrared light and projector. Sci Technol Dev J 20(K2):91–95CrossRef
Metadata
Title
Portable Hand Vein Finder System Based on Near-Infrared Illumination and Morphological Image Processing
Authors
Pham Van Quan
Phan Nguyen Nhue
Le Duy Tuan
Le Hoang Hai
Le Anh Tu
Dao Nguyen Thuan
Ta Van Duong
Copyright Year
2022
DOI
https://doi.org/10.1007/978-3-030-75506-5_9

Premium Partner